Troubleshooting
Problem
Serial Over LAN (SOL) unreliable at 9600 baud rate and above - IBM eServer 325, 326
Resolving The Problem
| Source |
|---|
Retain tip: H183684
| Symptom |
|---|
Dropped connections and poor performance may occur when configuring Serial over LAN at baud rates of 9600 or higher.
| Affected configurations |
|---|
The system may be any of the following IBM eServers:
- an eServer 326, type 8848, any model
- an eServer 325, type 8835, any model
The BIOS levels affected are:
all
| Solution |
|---|
None
| Workaround |
|---|
Configure system to use no higher than 4800 bauds for the console serial speed when using Serial over LAN. This is a current limitation of the system. The internal bus between the Broadcom ethernet controller and the BMC is unable to accommodate connections over 9600 bauds.
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20C","label":"Older System x->eServer 325"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20S","label":"Older System x->eServer 326"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]