Troubleshooting
Problem
If the system-error LED on your BladeCenter HS20 unit is lit, use the following table to help determine the cause of the error and the action you should take.
Resolving The Problem
The system-error LED on the system LED panel is lit when certain system errors occur. If the system-error LED on your BladeCenter HS20 unit is lit, use the following table to help determine the cause of the error and the action you should take.
| Lit LED | Cause | Action |
|---|---|---|
|
BladeCenter HS20 system LED panel
|
||
| None | An error has occurred and cannot be isolated, or the service processor has failed. | An error has occurred that is not represented by a Light Path Diagnostics LED. Check the system error log for more information about the error. |
| Processor x error | The microprocessor has failed. |
|
| Memory/DIMM error | A memory error occurred. |
Note: Multiple DIMM LEDs do not necessarily indicate multiple DIMM failures. If more than one DIMM LED is on, reseat/replace one DIMM at a time until error goes away. Refer to the BladeCenter management module system error log for further isolation. |
| Temperature error | The system temperature has exceeded a threshold level. |
Note: Air temperature:
|
| System board error | The system board has failed |
|
| IDE bus x error | The IDE bus indicated by the error LED has failed. |
|
| NMI error | The system board has failed. |
|
| Processor mismatch | The processors do not match. | Verify that microprocessors 1 and 2 have the same cache size and type and the same clock speed. Internal and external clock frequencies must be identical. |
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
29 January 2019
UID
ibm1MIGR-56991