Download
Version
1.05
Release Date
16 January 2007
Downloadable File
| File link | File size | File description |
|---|---|---|
| 2,745 | CHANGE HISTORY for the RSA II firmware update | |
| 5,672 | XML for the RSA II firmware update | |
| 8,268 | README for the RSA II firmware update | |
| 1,912,796 | IBM RSA II firmware update for Microsoft Windows |
Abstract
Download the latest IBM eServer xSeries 306 Remote Supervisor Adapter II Firmware Update for Windows.
Download Description
| New IBM xSeries firmware and device driver file naming convention |
Severity: Suggested
|
Change history
|
|---|
Version 1.05, UPE815C
Problem(s) Fixed:
- Corrected a problem where the Linux & Windows flash utilities
appear to hang while flashing.
Enhancement:
- Added support for the year 2007 US Daylight Saving Time changes.
Limitations:
Dependencies:
Version 1.04, UPE815A
Problem(s) Fixed:
- Corrected a problem where the DHCP lease does not get renewed when the DHCP server is not on the same subnet mask/network as the Remote Supervisor Adapter II
- Corrected a problem that caused the Remote Supervisor Adapter II to not aquire a new DHCP IP address when the old IP address is lost
- Corrected a caching problem that caused LDAP DNS look-ups to fail
- Corrected a problem that caused the lflash or wflash utility to fail intermittently
Enhancement:
- Added support to authenticate through LDAP using an account that has the display name and SAMAccount name set to different values
- Added French-Canadian keyboard support
- Changed maximum size of login string from 32 to 64 to support longer UPN or DN names
- Allowed dashes in the LDAP ASM Group Filter Name
- Increased the time to live to 128 on all packets from the Remote Supervisor Adapter to accommodate an increased number of network hops
Limitations:
Dependencies:
Version 1.03, UPE813A
- Added 64-bit support to the lflash utility
- Corrected a problem that would very infrequently cause the Remote Supervisor Adapter II to hang when power is first applied to the adapter card
- Corrected a problem where the server could become non-responsive 76 days after the Remote Supervisor Adapter II has been reset
- Changed the fan fail algorithm to prevent false fan fail indications
Version 1.02
- Raised the planar temperature thresholds
Version 1.01
- Added support for encrypted remote control
- Added LDAP DNS support
- Added support for more commands to the command line interface
Version 1.00
- Initial release
Off
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW20K","label":"xSeries 306"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]
Was this topic helpful?
Document Information
Modified date:
27 September 2013
UID
ibm1MIGR-54941