Working with drives in bays 1 through 4 - Netfinity 1000

Troubleshooting


Problem

Working with drives in bays 1 through 4 You install drives from the front of the server without removing the drive bay assembly. The drive bay assembly is permanently mounted to the chassis and cannot be removed.

Resolving The Problem

Working with drives in bays 1 through 4
You install drives from the front of the server without removing the drive bay assembly. The drive bay assembly is permanently mounted to the chassis and cannot be removed. The following illustration shows the server bays.

server drive bay locations


NOTE:
The front drive bay assembly is also known as the upper drive bay assembly.

Attention
The presence of 5 V ac standby power might result in damage to the hardware unless you disconnect the power cord from the electrical outlet before you open the server.

NOTE:

  • Read "Safety information" in the HMM.
  • Read the instructions that come with the drive that you want to install or replace.
  • Position the server as described in "Accessing the system board" in the HMM.
Installing drives in the front drive bay assembly
This section gives the procedure for installing drives in the front drive bay assembly. If you want to remove a drive from the front drive bay assembly, follow the steps in Removing drives from the drive bay assembly.

NOTE:
1. Remove the bay panel (bezel) for the drive bay where you are installing the drive.
  • a. Locate the appropriate bay panel (bezel) in the front of the server.
  • b. Use the tip of a screwdriver, if necessary, to release the plastic tabs that hold the bay panel at the front of the server.
  • c. Remove the bay panel.

removing the bay panel

2. If knockouts are present in the drive bay opening, twist them with a screwdriver or pliers to remove. The following illustration shows the type of knockout in bays 2 and 3.
knockout

3. Install the drive in the bay opening and secure the drive by inserting screws.

NOTE:
As shown in the following illustration, only two screws are needed to secure the drive within the drive bay.

drive bay screw locations

4. Attach the cables to the drive. See ISA and PCI adapters for an illustration that shows the locations of the connectors on the riser card.

attaching cables

5. If the installed drive has non-removable media, replace the bay panel (bezel).

bezel

6. If you installed a CD-ROM drive and want to connect the drive to the CD-ROM audio connector, see ISA and PCI adapters to locate the CD-ROM audio connector on the riser card.

7. If you want to install or remove any other options, do so now. Otherwise, go to Completing the installation.

Removing drives from the drive bay assembly
To remove drives from the drive bay assembly, do the following:

1. If the drive being removed has non-removable media, remove the bay panel (bezel).
  • a. Locate the appropriate bay panel (bezel) in the front of the server.
  • b. Use the tip of a screwdriver, if necessary, to release the plastic tabs that hold the bay panel at the front of the server.
  • c. Remove the bay panel.

removing the bay panel

2. Disconnect the cables from the drive that you want to remove.


disconnecting cables

3. Remove the visible screws that hold the drive and slide it out the front of the server.

removing drive


4. If you are not installing another drive, replace the bay panel (bezel).

replacing the bezel

5. If you want to install or remove any other options, do so now. Otherwise, go to Completing the installation.

Installing a drive in the drive bay assembly
This section gives the procedure for installing drives in the front drive bay assembly. If you want to remove a drive from the front drive bay assembly, reverse the order of the following steps.

Note
1. With the front of the drive bay assembly facing you, remove the metal shield for the drive bay you want to use by pulling out the tabs on the sides of the shield until it flexes. Lift off one side, then the other.

removing the metal shield

2. Touch the static-protective package containing the new drive to any unpainted metal surface; then, remove the drive from it.

3. Insert the drive into the desired unoccupied drive bay. Insert and tighten the screws that hold it in place. The following illustration shows a hard disk drive being installed in bay 2.
hard disk drive being installed

4. Replace the top-handle cover.
replacing the cover

5. Attach the cables to the drive, as shown in the following illustration.

attaching cables

6. If you have installed a drive with removable media, you must remove the bay panel (bezel). If you have installed a drive with non-removable media, you must install a bay panel (if it was not already installed).
  • To remove a bay panel (bezel), go to step 7.
  • To install a bay panel, go to step 8.
7. To remove a bay panel (bezel):  
  • a. Locate the appropriate bay panel in the front of the server.
  • b. Use the tip of a screwdriver, if necessary, to release the plastic tabs that hold the bay panel at the front of the server.
  • c. Remove the bay panel.

removing the bay panel

  • d. Continue with step 9.

8. To install a bay panel (bezel):

  • a. Align the right-hand edge of the bay panel with the matching opening in the front of the server.
  • b. Gently press the left edge closed until it snaps.

installing a bezel

9. If you want to install or remove any other options, do so now. Otherwise, go to Completing the installation.

 