IBM Support

Power supply controls/indicators and replacing hot-swap power supplies - Netfinity EXP15 (Type 3520)

Product Documentation


Abstract

Source Hardware Maintenance Manual Power supply controls and indicators Power supply LED indications

Content

Source
Hardware Maintenance Manual

Power supply controls and indicators

controls and indicators


Power supply LED indications

LED Description
Power (green) LEDs are on when power switches are turned on.
Fault (amber) If only the amber LED is on, then power supply is off.
Power (green) and Fault (amber) Both the green and amber LEDs on indicates a power supply failure.




Replacing power supplies (Hot-swap)
replacing power supplies

To remove a power supply

  1. Turn the switch on the power supply to the off position.
  2. Unplug the supply power cord from the electrical outlet.
  3. Disconnect the power cord from the power supply.
  4. Grasp each pull-ring and squeeze the latches to release.
  5. Pull open lever and remove power supply.

 

NOTE:
When installing a new power supply, make sure that the latch is mounted to the side of the supply that is toward the middle of the machine. If not, remove the lever screw, flip the lever over and replace the screw. See the illustration above.

Document Location

Worldwide

Operating System

System x:All operating systems listed