switches

The expansion unit has three types of ID numbers:

Drive SCSI IDs Identifies each drive in the expansion unit.
Tray ID Identifies each expansion unit
SAF-TE chip SCSI ID System-management SCSI Accessed Fault Tolerant Enclosure processor


Switch settings are as follows:

Option switches

  • Switch 1 off (default)

Bus 1 and 2 as Single Bus 1, accessing all ten drives, (IDs 0-4 and 8-12).


  • Switch 1 on
Bus 1 and Bus 2 accessing 5 drives each.
Bus 1 accessing IDs 0-4
Bus 2 accessing IDs 0-4


NOTE:
Option switches 2-5 must be set to the Off (down) position. Errors might occur if these switches are set to the on position.

Tray number switch
  • Identifies each expansion unit 0-9.

SAF-TE chip SCSI ID
  • Internal SCSI ID numbers 14 and 15.