To remove a Drive from bay 1, 2 or 3:

Remove the Left-side Cover:

  1. Unlock the side cover and press the cover-release latch down while rotating the top edge of the cover away from the server; then, lift the cover off the server and set it aside.

Remove the Bezel :

  1. Release the three tabs on the left edge of the bezel and rotate the bezel away from the server; then, pull the bezel away from the server.

    Here's a closer look at a latching tab.

Remove a Drive from Bay 1, 2 or 3:

  1. Disconnect the drive power cable, … and signal cable.
  2. Squeeze the blue tabs on each side of the drive, while pulling the drive out of the bay.
  3. Using a flat-bladed screwdriver, release the spring retainer and lift the rails from the drive.