Product Documentation
Abstract
1. Release latches 2. Fan housing Removing the four fan housing Power-off the server. Disconnect the server from the power supply. Remove the top cover and bezel. Remove the four fan assemblies.
Content

1. Release latches
2. Fan housing
| Removing the four fan housing |
|---|
- Power-off the server.
- Disconnect the server from the power supply.
- Remove the top cover and bezel.
- Remove the four fan assemblies.
- Remove all adapters from the Active PCI adapter slots.
- Remove the plastic dividers between the PCI adapter slots.
- Press the fan assembly release latches on both sides of the fan assembly; then, remove the fan assembly from the server.

1. Holding screws
2. Dual fan mount assembly
| Removing the dual fan mount assembly with cable |
|---|
- Power-off the server.
- Disconnect the server from the power supply.
- Remove the top cover and bezel.
- Disconnect the dual fan mount cable.
- Remove the two holding screws.
- Gently lift the fan mount assembly out of the server.
Document Location
Worldwide
[{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HW18V","label":"Older System x->xSeries 350"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}},{"Type":"HW","Business Unit":{"code":"BU016","label":"Multiple Vendor Support"},"Product":{"code":"HWN12","label":"Older System x->Netfinity 6000R"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Line of Business":{"code":"","label":""}}]