Product Documentation
Abstract
The server comes with six hot-swap fans. You do not need to turn off the power to the server to replace a hot-swap fan assembly. WARNING: To help ensure proper cooling, replace a fan that has failed within 48 hours.
Content
The server comes with six hot-swap fans. You do not need to turn off the power to the server to replace a hot-swap fan assembly.
WARNING: To help ensure proper cooling, replace a fan that has failed within 48 hours.
Note: The speed of the fans will increase if:
- One fan fails.
- Ambient temperature gets too high.
The following illustration shows how to replace hot-swap fans.
Note: The illustrations in this document might differ slightly from the hardware.

Replacing a hot-swap fan assembly
- Remove the top cover.
Note: To ensure proper system cooling, do not remove the top cover for more than 30 minutes during this procedure.
- Lift the fan release handle and lift the fan out of the server.
- Slide the replacement fan into the server and press the handle down.
- Replace the top cover.
Document Location
Worldwide
Was this topic helpful?
Document Information
Modified date:
24 January 2019
UID
ibm1MIGR-45547