Problem

421 Timeout (900 seconds): closing control connection. (SCI71137)

Symptom

421 Timeout (900 seconds): closing control connection.
Replies 150 and 226 arrive in the same TCP buffer.

Cause

Replies 150/226 in one TCP buffer causes FTP client session failure.

Resolving The Problem

Apply Post CUM1205 P122704 which includes fix 34050.



FIX 34050 SR 1338368



Replies 150/226 in one TCP buffer causes FTP client session failure.



When a LIST command is issued by the C:E FTP client, and the reply



contains both the 150 and 226 msgs in one TCP buffer, the session hangs



for FTP_DEFAULT_DISCINTV plus 5 seconds after which the FTP session is



lost, reply code 605 is generated by the client, the HCRC variable is



set to 16, and the summary log record has fail code 146. This occurs



whether or not there is any data sent back on the DP. If data is sent



on the data port, the resulting batch containing the directory listing



is marked incomplete. This fix addresses these problems as summarized



in the following table. As part of this fix, the MAXRC variable is



checked and possibly updated for each REPLY.n variable set. This may



require script changes if the final value of this variable changes.



F34050 Data Incomplete Hang MAXRC HCRC Summary



Applied Sent Batch Time FailCode



------- ---- ----------- ---- ----- ---- --------



N N D+5 605 16 146



N Y Y D+5 605 16 146



Y N 0 600 0



Y Y N 0 226 0



ACTION: As part of this fix, the MAXRC variable is checked and possibly



updated for each REPLY.n variable set. This may require script changes



if the final value changes.



MODULES UPDATED: STFTPC45,STREXX08



LOAD MODULES AFFECTED: STFTPC45,STREXX08

[{"Product":{"code":"SSG266","label":"IBM Sterling Connect:Enterprise for z\/OS"},"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Component":"Not Applicable","Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"All","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]