Troubleshooting
Problem
The initialization of IBM Sterling Connect:Direct for z/OS 5.2 fails with 081E - Message cannot be found directly after the Netmap is opened.
Symptom
HH.MM.SS STC09999 SITA001I IBM Sterling Connect:Direct for z/OS
initialization has begun.
HH.MM.SS STC09999 SITA002I Connect:Direct parameter file allocated
and open.
HH.MM.SS STC09999 SITA022I Loading Connect:Direct modules.
HH.MM.SS STC09999 SITA601I The TCP server modules are loaded.
HH.MM.SS STC09999 SITA067I MESSAGE file is open.
HH.MM.SS STC09999 SITA023I Initializing Connect:Direct storage.
HH.MM.SS STC09999 SITA024I Building the TCA chain.
HH.MM.SS STC09999 SITA026I Creating the system tasks (master and
timer).
HH.MM.SS STC09999 SITA025I Building the ECB address list.
HH.MM.SS STC09999 SITA027I Building the DDN table.
HH.MM.SS STC09999 SITA069I NETWORK MAP file is open.
HH.MM.SS STC09999 081E - Message cannot be found.
HH.MM.SS STC09999 GSDMV20I -JOBNAME STEPNAME PROCSTEP CCODE ELAPSED-
TIME CPU-TIME STEPNO
HH.MM.SS STC09999 GSDMV21I -CDNAME STARTING CDITASK 16 00:
00:SS 0.10S 1
HH.MM.SS STC09999 IEF404I CDNAME - ENDED - TIME=HH.MM.SS
Cause
In order to still support the encryption of the NETMAP, AUTH, TCQ/TCX, and Secure Plus PARMFILE, the product was altered to use the Integrated Cryptographic Service Facility (ICSF) of the IBM SystemSSL Toolkit.
Resolving The Problem
Secure+ for Sterling Connect:Direct 5.2 and above requires ICSF. Cryptographic coprocessors are also required unless FMID HCR77A0 or higher is installed.