POWER7 information

SYSBKP2

The failing component is the system backplane.

After you have replaced the part, set the enclosure serial number before powering up, otherwise the machine will not perform an IPL. See the system unit service information for more information regarding setting the enclosure serial number.

Use the following table to determine the part number for the field replaceable unit (FRU).

CCIN or FFC Type and model Part number Description Location code
  8233-E8B, 8236-E8C See System parts. System backplane Un-P1
  8248-L4T, 8408-E8D, 8412-EAD, 9109-RMD, 9117-MMB, 9117-MMC, 9117-MMD, 9179-MHB, 9179-MHC, 9179-MHD See System parts. System backplane Un-P2

If you need additional information for failing part numbers, location codes, or removal and replacement procedures, see Part locations and location codes. Select your machine type and model number to find additional location codes, part numbers, or replacement procedures for your system.

This ends the procedure.



Send feedback Rate this page