Loading coprocessor code

IBM® 4767 crypto adapters are supported.

  1. Change segment 1:
    1. If the segment 1 image name indicates ... Factory ..., set the application to Factory Mode (File > Factory Mode). The Factory Mode CLU window opens.
      Figure 1. CLU File menu
      CLU File menu

      Reload segment 1 with the CCA segment 1 file by selecting Load Factory Segment 1 and clicking Run.

    2. If the segment 1 image name does not indicate ... Factory ..., and the segment 1 revision level is less than 50000, reload segment 1 with the CCA segment 1.
      Note: This choice is only available when the application is not in Factory Mode (File > Factory Mode).
  2. Change segments 2 and 3:
    1. If segment 2 ROM status indicates Unowned… Set the application to Factory Mode (File > Factory Mode). Select Load Factory Segments 2 and 3 (establish_ownership_then_emergency_reload_seg2_seg3_TKE_5.0.xx.clu) and click Run.
    2. If segment 2 and 3 ROM status both indicate owner 02… Select Load Owned Segments 2 and 3 (reload_seg2_seg3_TKE_5.0.xx.clu) and click Run.
      Note: This choice is only available when the application is not in Factory Mode (File > Factory Mode).
  3. When you have successfully completed this process, a check of the coprocessor status or validate of the coprocessor code indicates that the segments contain:

    Segment 1 Image: 5.0.xx Pxx
    Segment 2 Image: 5.0.xx 1xx
    Segment 3 Image: 5.0.xx CCA TKE

    where the xx values are dependent on the maintenance level of the TKE.

    View the results in the Output Log or Command History.