Loading coprocessor code
IBM® 4767 crypto adapters are supported.
- Change segment 1:
- If the segment 1 image name indicates ... Factory ..., set the
application to Factory Mode (File > Factory Mode).
The Factory Mode CLU window opens.Figure 1. CLU File menu

Reload segment 1 with the CCA segment 1 file by selecting Load Factory Segment 1 and clicking Run.
- If the segment 1 image name does not indicate ... Factory ...,
and the segment 1 revision level is less than 50000,
reload segment 1 with the CCA segment 1.Note: This choice is only available when the application is not in Factory Mode (File > Factory Mode).
- If the segment 1 image name indicates ... Factory ..., set the
application to Factory Mode (File > Factory Mode).
The Factory Mode CLU window opens.
- Change segments 2 and 3:
- If segment 2 ROM status indicates Unowned… Set the application to Factory Mode (File > Factory Mode). Select Load Factory Segments 2 and 3 (establish_ownership_then_emergency_reload_seg2_seg3_TKE_5.0.xx.clu) and click Run.
- If segment 2 and 3 ROM status both indicate owner 02… Select Load Owned Segments 2 and 3 (reload_seg2_seg3_TKE_5.0.xx.clu)
and click Run. Note: This choice is only available when the application is not in Factory Mode (File > Factory Mode).
- When you have successfully completed this process, a check of
the coprocessor status or validate of the coprocessor code indicates
that the segments contain:
Segment 1 Image: 5.0.xx Pxx
Segment 2 Image: 5.0.xx 1xx
Segment 3 Image: 5.0.xx CCA TKE
where the xx values are dependent on the maintenance level of the TKE.View the results in the Output Log or Command History.