Error codes

This topic describes the tape library error codes.

Table 1 lists the severity, the SNMP trap ID, and the URC for each error code.

Table 1. Library events
Error code Description Severity SNMP trap ID URC

0001

Cartridge {VOLSER} could not be read.

Warning

201

C001

0002

Cartridge {VOLSER} could not be written to.

Warning

202

C002

0003

Cartridge {VOLSER} had a read, write, or positioning error.

Warning

203

NA

0004

Cartridge {VOLSER} had a read, write, or positioning error because of faulty media.

Warning

204

NA

0005

Cartridge {VOLSER} could not be read from because of faulty media or a faulty drive.

Warning

205

0xC005

0006

Cartridge {VOLSER} could not be written to or there was a positioning error because of faulty media or a faulty drive.

Warning

206

NA

0007

Cartridge {VOLSER} reached its end of life.

Warning

207

NA

0008

Cartridge {VOLSER} is not suitable for long term data storage.

Warning

208

NA

0009

A write command failed because cartridge {VOLSER} is write-protected.

Informational

209

NA

000A

A drive unload was attempted while media removal was prevented.

Informational

210

NA

000B

A cleaning tape was loaded into a drive.

Informational

211

NA

000C

Cartridge {VOLSER} is not supported by the drive.

Informational

212

NA

000D

Cartridge {VOLSER} had a mechanical failure. The cartridge was unloaded.

Warning

213

NA

000E

Cartridge {VOLSER} had a mechanical failure. The cartridge was not unloaded.

Error

214

0xC00E

000F

A drive detected the cartridge memory in cartridge {VOLSER} failed.

Warning

215

NA

0010

Cartridge {VOLSER} was manually removed from a drive with a read or write in process.

Informational

216

NA

0011

A drive rejected a write attempt to a read-only cartridge {VOLSER}.

Informational

217

NA

0012

At load time, a drive detected a corrupted directory for cartridge {VOLSER}.

Warning

218

NA

0013

Cartridge {VOLSER} was nearing its end of life

If you encounter this error, perform the following steps from the host:
  1. Copy the data from the expiring cartridge to a different cartridge.
  2. Eject the expiring cartridge and remove it from the library.

Warning

219

N/A

0014

A drive requested a cleaning.

Informational

220

NA

0015

A drive requested a routine cleaning.

Informational

221

NA

0016

A drive detected an expired cleaning cartridge {VOLSER}.

Informational

222

NA

0017

A drive detected an invalid cleaning cartridge {VOLSER}.

Warning

223

NA

0018

A drive reported TapeAlert flag 24.

Informational

224

NA

0019

Drive Fibre channel interface failed.

Error

225

0xC020

001A

Drive cooling fan failed.

Error

226

0xC01A

001B

Drive power supply failed.

Error

227

0xC01B

001C

A drive reported TapeAlert flag 28.

Informational

228

NA

001D

A drive reported a condition that requires drive diagnostics.

Warning

229

N/A

001E

A drive failed. A drive reset is required.

Error

230

0xC01E

001F

Drive power-on self-tests failed. A drive hard reset is required.

Error

231

0xC01F

0020

Drive Fibre channel interface failed.

Error

232

0xC020

0021

A failure occurred that requires cartridge {VOLSER} to be demounted from the drive and retried.

Warning

233

NA

0022

A drive firmware update process failed..

Informational

234

NA

0023

A drive detected that the humidity is outside the specified operational limits.

Warning

235

NA

0024

A drive detected that the temperature is outside the specified operational limits.

Warning

236

NA

0025

Drive power-supply voltages are outside the specified operational limits.

Error

237

0xC025

0026

A drive reported a condition that requires drive diagnostics.

Warning

238

0xC026

0027

A drive reported a condition that requires drive diagnostics.

Error

239

0xC027

0028

A drive reported TapeAlert flag 40.

Informational

240

NA

0029

A drive reported TapeAlert flag 41.

Informational

241

NA

002A

A drive reported TapeAlert flag 42.

Informational

242

NA

002B

A drive reported TapeAlert flag 43.

Informational

243

NA

002C

A drive reported TapeAlert flag 44.

Informational

244

NA

002D

A drive reported TapeAlert flag 45.

Informational

245

NA

002E

A drive reported TapeAlert flag 46.

Informational

246

NA

002F

A drive reported TapeAlert flag 47.

Informational

247

NA

0030

A drive reported TapeAlert flag 48.

Informational

248

NA

0031

Cartridge {VOLSER} was initialized as partitioned or capacity-scaled.

Informational

249

NA

0032

Cartridge {VOLSER} usage statistics were lost. No action required.

Informational

250

N/A

0033

At unload time, a drive detected a corrupted directory for cartridge {VOLSER}.

Warning

251

0xC033

0034

Cartridge {VOLSER} system area could not be written to.

Warning

252

0xC034

0035

Cartridge {VOLSER} system area could not be read.

Warning

253

0xC035

0036

Cartridge {VOLSER} does not have a valid start of data.

Warning

254

0xC036

0037

Cartridge {VOLSER} could not be loaded and threaded.

Warning

255

0xC037

0038

Cartridge {VOLSER} could not be unloaded.

Error

256

0xC038

0039

A drive library interface failed. A drive reset is recommended.

Warning

257

NA

003A

A drive performed a self-reset.

Informational

258

N/A

003B

WORM cartridge {VOLSER} has suspect data.

Warning

259

0xC03B

003C

An overwrite command failed for WORM cartridge {VOLSER}.

Informational

260

NA

003D

A drive is configured to require encryption, but encryption is not enabled.

Warning

261

N/A

003E

A drive reported TapeAlert flag 62.

Informational

262

NA

003F

A drive reported TapeAlert flag 63.

Informational

263

NA

0040

A drive reported TapeAlert flag 64.

Informational

264

NA

0200

I/O station full.

Informational

401

NA

0201

The I/O station has been open for five or more minutes.

Warning

405

NA

0202

An I/O station was opened.

Informational

483

NA

0203

An I/O station was closed.

Informational

484

NA

0210

The library ran out of LTO cleaning cartridges.

Warning

403

NA

0211

The library ran out of 3592 cleaning cartridges.

Warning

409

NA

0212

LTO cleaning cartridge {VOLSER} expired

Warning

406

NA

0213

3592 cleaning cartridge {VOLSER} expired

Warning

410

NA

0214

The library was almost out of licensed LTO storage slots

Warning

424

NA

0215

The library was almost out of licensed 3592 storage slots

Warning

425

NA

0216

The library ran out of licensed 3592 storage slots.

Warning

426

NA

0217

The library ran out of licensed LTO storage slots

Warning

427

NA

0218

The logical library {LOG_LIB} was almost full

Warning

416

NA

0219

The logical library {LOG_LIB} was full.

Warning

402

NA

021A

A shuffle operation failed because there were no open slots in the library

Warning

407

NA

021C

The library detected a new unassigned cartridge {VOLSER}.

Warning

421

NA

021E

Cartridge {VOLSER} could not be assigned to logical library {LOG_LIB} because VIO was full.

Warning

478

NA

0220

A library front door was opened.

Warning

16

NA

0221

All library doors were closed

Informational

422

NA

0230

A frame inventory was started.

Informational

429

NA

0240

Call home started

Informational

431

NA

0241

Call home failed

Warning

415

NA

0242

Test call home started

Informational

432

NA

0243

Required LTO diagnostic cartridge was not found at the required location.

Informational

433

NA

0244

Required 3592 diagnostic cartridge was not found at the required location.

Informational

434

NA

0245

Call home finished

Informational

432

NA

0247

Service logs exported to IBM

Informational

482

N/A

0248

Library snapshot created.

Informational

0

NA

0249

System console not responding

Warning

495

N/A

0250

A cartridge that cannot be encrypted was loaded into a drive that is set to encrypt all cartridges

Warning

420

NA

0261

During a test, the encryption key manager address failed.

Warning

419

NA

0262

During a test, the encryption key manager path failed

Warning

419

NA

0263

During a test, the encryption key manager full path check failed

Warning

419

NA

0264

The security settings HTTPS certificate will expire in 30 days.

Warning

462

NA

0265

The security settings HTTPS certificate has expired.

Error

463

0xA763

0280

Accessor {ACCESSOR} could not read a barcode.

Warning

32

0xA4C5

0290

There is no Media Verification drive for cartridge {VOLSER} generation.

Warning

464

NA

0291

Media Verification failed for cartridge {VOLSER}

Error

465

0xA790

0292

There is only one Media Verification drive assigned to the logical library {LOG_LIB} and it failed

Error

466

0xA791

0293

Media Verification passed for cartridge {VOLSER}

Informational

0

NA

0295

Media Verification drive failed after multiple put errors.

Error

467

0xA792

02B1

A move failed because there was not a demount destination available.

Warning

407

N/A

02B2

A move failed because there was not a Tier0 destage destination available

Warning

407

N/A

02B3

A move failed because there was not an elastic destage destination available.

Warning

407

N/A

02B4

A move failed because there was not an import destination available.

Warning

407

N/A

02B5

A move failed because there was not an ERP destination available.

Warning

407

N/A

02C0

Cartridge {VOLSER} with an L7 density was unloaded.

Informational

0

NA

02C1

Cartridge {VOLSER} with an M8 density was unloaded.

Informational

0

NA

02D0

Accessor {ACCESSOR} could not read cartridge barcode label

Informational

491

NA

02D1

Cartridge CM Volser changed from {VOLSER} to {VOLSER}

Informational

492

NA

0300

An LCC was unable to communicate with an air conditioning unit.

Error

472

N/A

0302

An LCC was unable to communicate with a temperature and humidity sensor

Error

474

N/A

0303

An air conditioning compressor was off unexpectedly

Error

475

N/A

0304

An environmental LED state was changed to Red - Do Not Open Door

Informational

0

N/A

0305

An environmental LED state was changed to Yellow - Use Caution when Opening Door

Informational

0

N/A

0306

An environmental LED state was changed to Green - OK to Open Door

Informational

0

N/A

0307

Drives were set to environmental protection mode

Warning

476

N/A

0308

Ambient environment was out of specification at {TEMPERATURE}°C and {HUMIDITY}% RH.

Warning

477

N/A

0310

A request to open a door was made

Informational

0

N/A

0311

Library service was completed

Informational

0

N/A

0312

Library service exceeded 30 minutes

Error

479

N/A

0313

Library air conditioning normal operation was resumed

Informational

0

N/A

0320

Ship preparation started

Informational

0

N/A

0321

Ship preparation finished successfully

Informational

0

N/A

0322

Ship preparation failed

Error

0

N/A

0700

The state of the library changed from {OLD_STATE} to {NEW_STATE}.

Informational

0

N/A

0701

The state of drive {DRIVE} changed from {OLD_STATE} to {NEW_STATE}.

Informational

0

N/A

0702

The state of accessor {ACCESSOR} changed from {OLD_STATE} to {NEW_STATE}.

Informational

0

N/A

0703

The state of LCC node card {FRAME} changed from {OLD_STATE} to {NEW_STATE}.

Informational

0

N/A

0704

The state of ACC node card {ACCESSOR} changed from {OLD_STATE} to {NEW_STATE}.

Informational

0

N/A

0705

The state of MDA node card {ACCESSOR} changed from {OLD_STATE} to {NEW_STATE}.

Informational

0

N/A

0706

The state of Frame {FRAME} changed from {OLD_STATE} to {NEW_STATE}.

Informational

0

N/A

0707

The state of power supply {SIDE} in frame {FRAME} changed from {OLD_STATE} to {NEW_STATE}.

Informational

   

0800

A user logged in to the GUI from {IPADDRESS}

Informational

440

NA

0801

A user failed to login from {IPADDRESS}

Informational

441

NA

0802

A library setting was changed

Informational

443

NA

0803

A logical library {LOG_LIB} setting was changed

Informational

444

NA

0804

A tape drive setting was changed

Informational

445

NA

0805

A cartridge setting was changed

Informational

446

NA

0806

Library firmware update started.

Informational

447

NA

0807

Library firmware update failed

Informational

455

NA

0808

A corrupted library firmware image was downloaded.

Informational

456

NA

0809

Drive firmware update failed.

Informational

457

NA

080A

ACC/MDA firmware update finished.

Informational

458

NA

080B

LCC firmware update finished.

Informational

458

NA

080C

Accessor {ACCESSOR} FRU replacement finished.

Informational

448

NA

080D

Drive FRU replacement finished

Informational

449

NA

080E

A drive serial number changed

Informational

450

NA

080F

A drive was reset

Informational

451

NA

0810

An administrator password was changed

Informational

453

NA

0811

An SNMP test trap was sent from the GUI

Informational

408

NA

0812

A user logged out of the GUI from {IPADDRESS}

Informational

442

NA

0813

Library security settings changed.

Informational

20

NA

0814

The library was set offline

Informational

21

NA

0815

A drive was offline

Informational

22

NA

0816

Accessor {ACCESSOR} MDA card was reset by a user.

Informational

452

NA

0817

Accessor {ACCESSOR} ACC card was reset by a user.

Informational

452

NA

0818

An LCC card was reset by user.

Informational

452

NA

0819

The library was reset by user.

Informational

452

NA

081A

The access recovery button was pressed.

Informational

460

NA

081B

User account locked

Informational

461

NA

081C

A service user logged in to the GUI from {IPADDRESS}

Informational

471

NA

081D

Accessor {ACCESSOR} MDA card was reset.

Informational

485

NA

081E

Accessor {ACCESSOR} ACC card was reset.

Informational

485

NA

0820

A drive beacon was turned on

Informational

487

NA

0821

A drive beacon was turned off

Informational

488

NA

0822

A drive was hard reset

Informational

489

NA

0900

Calibrate frame with accessor {ACCESSOR} started.

Informational

0

NA

0901

Calibrate frame with accessor {ACCESSOR} finished.

Informational

0

NA

0902

Accessor {ACCESSOR} calibrate started.

Informational

0

NA

0903

Accessor {ACCESSOR} calibrate finished.

Informational

0

NA

0904

Calibrate I/O with accessor {ACCESSOR} started.

Informational

0

NA

0905

Calibrate I/O with accessor {ACCESSOR} finished.

Informational

0

NA

0906

Calibrate drive with accessor {ACCESSOR} started.

Informational

0

NA

0907

Calibrate drive with accessor {ACCESSOR} finished.

Informational

0

NA

090C

Drive firmware update started.

Informational

447

NA

090D

Drive firmware update finished.

Informational

459

NA

090E

Library firmware update started.

Informational

447

NA

090F

Library firmware update finished.

Informational

458

NA

0911

Inventory finished.

Informational

430

NA

0912

Inventory with audit started.

Informational

429

NA

0913

Inventory with audit finished.

Informational

430

NA

0914

Library verify started.

Informational

0

NA

0915

Library verify finished.

Informational

0

NA

0916

Library diagnostics started.

Informational

0

NA

0917

Library diagnostics finished.

Informational

0

NA

091A

Drive FRU replacement started.

Informational

0

NA

091C

Drive log download started.

Informational

0

NA

091D

Drive log download finished.

Informational

0

NA

091E

Discover hardware started.

Informational

0

NA

091F

Discover hardware finished.

Informational

0

NA

0920

VOLSER range update started.

Informational

0

NA

0921

VOLSER range update finished.

Informational

444

NA

0922

Accessor {ACCESSOR} FRU replacement started.

Informational

448

NA

0924

Calibrate library with accessor {ACCESSOR} started.

Informational

0

NA

0925

Calibrate library with accessor {ACCESSOR} finished.

Informational

0

NA

0926

Drive FRU replacement started

Informational

449

NA

0927

Drive FRU replacement finished

Informational

449

NA

0928

Drive test started.

Informational

0

NA

0929

Drive test finished.

Informational

0

NA

092A

The library was reset.

Informational

0

NA

2000

The pause button failed.

Error

2

NA

2001

The access recovery button failed.

Error

2

NA

2002

Library pause button was pressed

Informational

480

NA

2124

More than 8 LCC detected on library string

Warning

468

NA

2125

LCC card failed over

Warning

469

NA

2127

An LCC communication with Accessor {ACCESSOR} MDA card timed out.

Warning

499

N/A

2128

An LCC communication with Accessor {ACCESSOR} ACC card timed out.

Warning

500

N/A

2380

Accessor {ACCESSOR} ACC card failed.

Error

2

0xA413

2381

Accessor {ACCESSOR} ACC card CAN bus 1 failed.

Error

2

0xA413

2382

Accessor {ACCESSOR} ACC card CAN bus 2 failed.

Error

2

0xA413

2481

Accessor {ACCESSOR} MDA card CAN bus 1 failed.

Error

2

0xA414

2482

Accessor {ACCESSOR} MDA card CAN bus 2 failed.

Error

2

0xA414

2484

An LCC card was not responding over Ethernet

Warning

2

0xA427

2500

FPGA L Frame location was incorrect

Warning

481

N/A

3021

A library side door was opened.

Warning

16

NA

3024

A library side door was not detected

Error

2

0xA43B

3025

The service bay barrier was down when a side door was opened

Error

2

0xA43C

3026

The service bay barrier was up when a side door was closed

Error

2

0xA43C

3081

A frame was not found

Error

2

0xA431

3430

A 12V DC power supply would not turn on

Error

28

0xA514

34A1

A 12V DC power supply was not detected

Error

28

0xA457

3746

A drive was miscabled

Error

2

0xA624

3749

A BPC-G231-to-BPC cable was not connected correctly.

Error

2

0xA627

3750

An ASC to flex track cable was not plugged correctly

Error

2

0xA628

3752

An LCC to DSC communication failed

Warning

486

NA

3753

Library frame count in FPGA does not match configuration

Error

505

NA

3822

An LCC to drive communication failed

Warning

1

0xB80A

3833

An LCC card could not get a response from a drive

Error

1

0xB701

3834

Communication between an LCC card and a drive failed on Ethernet

Error

1

0xB702

3835

An LCC card could not communicate with a drive

Error

1

0xB703

3839

A drive or canister type did not match the configuration

Error

1

0xB707

383B

A drive diagnostic test returned an invalid status

Error

1

0xB709

383C

More than 128 Drives detected on library string

Warning

470

NA

4081

Gripper {GRIPPER} did not move.

Error

2

0xB401

4082

Gripper {GRIPPER} encountered an unexpected hard stop while extending.

Error

2

0xB402

4083

Gripper {GRIPPER} encountered an unexpected hard stop while retracting.

Error

2

0xB403

4084

Gripper {GRIPPER} encountered a high current condition while extending.

Error

2

0xB404

4085

Gripper {GRIPPER} encountered a high current condition while retracting.

Error

2

0xB405

4086

Gripper {GRIPPER} was unable to find a hard stop while extending

Error

2

0xB406

4087

Gripper {GRIPPER} was unable to find a hard stop while retracting

Error

2

0xB407

4088

Gripper {GRIPPER} was unable to get cartridge {VOLSER}

Error

2

0xB408

4089

Gripper {GRIPPER} was unable to put cartridge {VOLSER}

Error

2

0xB409

408A

Gripper {GRIPPER} lost power.

Error

2

0xB40A

408B

Gripper {GRIPPER} encountered a low current condition while retracting.

Error

2

0xB40B

408C

Gripper {GRIPPER} lost a cartridge.

Error

2

0xB40C

408D

Gripper {GRIPPER} is not aligned properly in the gripper cage.

Error

2

0xB40D

4181

Gripper {GRIPPER} sensor was blocked when it should not have been.

Error

2

0xB40E

4182

Gripper {GRIPPER} sensor was not blocked when it should have been.

Error

2

0xB40F

4183

Gripper {GRIPPER} sensor was in a degraded state.

Error

7

0xB40E

4184

Gripper {GRIPPER} sensor failed.

Error

2

0xB40E

4221

Accessor {ACCESSOR} X home sensor was blocked when it should not have been.

Error

2

0xA47A

4380

Accessor {ACCESSOR} X home sensor was not found during a re-zero.

Error

2

0xA471

4480

Accessor {ACCESSOR} Y home sensor was blocked when it should not have been.

Error

2

0xA480

4481

Accessor {ACCESSOR} Y home sensor was not found during rezero.

Error

2

0xA481

4580

Accessor {ACCESSOR} X motor did not move.

Error

2

0xA490

4581

Accessor {ACCESSOR} X motion could not find a hard stop while moving left.

Error

2

0xA491

4582

Accessor {ACCESSOR} X motion could not find a hard stop while moving right.

Error

2

0xA492

4583

Accessor {ACCESSOR} X motion encountered an unexpected hard stop while moving left.

Error

2

0xA493

4584

Accessor {ACCESSOR} X motion encountered an unexpected hard stop while moving right.

Error

2

0xA494

4585

Accessor {ACCESSOR} X motion required excessive force to move left.

Error

2

0xA495

4586

Accessor {ACCESSOR} X motion required excessive force to move right.

Error

2

0xA496

4587

Accessor {ACCESSOR} X motion failed due to loss of 40 V dc.

Error

2

0xA40A

4588

Accessor {ACCESSOR} X motion motor driver failed.

Error

2

0xA498

4589

Accessor {ACCESSOR} X motion position drift occurred.

Error

2

0xA499

4590

Accessor {ACCESSOR} X motion accessor rezero completed.

Informational

2

0xA475

4591

Accessor {ACCESSOR} rezero completed.

Informational

2

0xA476

4680

Accessor {ACCESSOR} Y motor did not move.

Error

2

0xA4A0

4681

Accessor {ACCESSOR} Y motion could not find a hard stop while moving up.

Error

2

0xA4A1

4682

Accessor {ACCESSOR} Y motion could not find a hard stop while moving down.

Error

2

0xA4A2

4683

Accessor {ACCESSOR} Y motion encountered an unexpected hard stop while moving up.

Error

2

0xA4A3

4684

Accessor {ACCESSOR} Y motion encountered an unexpected hard stop while moving down.

Error

2

0xA4A4

4685

Accessor {ACCESSOR} Y motion required excessive force to move up.

Error

2

0xA4A5

4686

Accessor {ACCESSOR} Y motion required excessive force required to move down.

Error

2

0xA4A6

4687

Accessor {ACCESSOR} Y motion failed because of a loss of 40V DC power.

Error

2

0xA40B

4688

Accessor {ACCESSOR} Y motion failed.

Error

2

0xA4A8

4689

Accessor {ACCESSOR} Y motion failed because of drift.

Error

2

0xA4A9

4690

Accessor {ACCESSOR} Y motion accessor rezero completed.

Informational

2

0xA485

4691

Accessor {ACCESSOR} Y motion drift was suspected.

Informational

2

0xA486

4780

Accessor {ACCESSOR} pivot motor could not move.

Error

2

0xA5B0

4781

Accessor {ACCESSOR} pivot motion could not find a hard stop.

Error

2

0xA5B1

4782

Accessor {ACCESSOR} pivot motion could not find a hard stop.

Error

2

0xA5B2

4783

Accessor {ACCESSOR} pivot motion encountered an unexpected hard stop.

Error

2

0xA5B3

4784

Accessor {ACCESSOR} pivot motion encountered an unexpected hard stop.

Error

2

0xA5B4

4785

Accessor {ACCESSOR} pivot motion required excessive force to pivot.

Error

2

0xA5B5

4786

Accessor {ACCESSOR} pivot motion required excessive force to pivot.

Error

2

0xA5B6

4787

Accessor {ACCESSOR} pivot motion failed because of a power loss.

Error

2

0xA4B8

4840

Accessor {ACCESSOR} XY positioning could not be determined.

Error

2

0xA4B9

4880

Accessor {ACCESSOR} failover occurred.

Error

2

0xA4BA

4890

Accessor {ACCESSOR} XY impact was detected

Error

2

0xA4BB

4891

Accessor {ACCESSOR} detected a cartridge in the accessor or gripper's path.

Error

2

0xA4BB

48A0

Accessor {ACCESSOR} detected an obstacle in the accessor or gripper's path

Error

2

0xA4BB

48B0

Accessor {ACCESSOR} re-zero failed.

Error

2

0xA4BC

4900

The number of cartridges in the library needs to be 4 times the number of frames for multi-frame verification testing

Error

0

N/A

4901

Multi-frame verification test failed

Error

0

N/A

4902

Multi-frame verification test completed successfully

Informational

0

N/A

4903

Multi-frame verification test has started

Informational

0

N/A

5B22

Accessor {ACCESSOR} barcode scanner cannot be triggered.

Error

2

0xA4C3

5B23

Accessor {ACCESSOR} barcode scanner cannot be triggered.

Error

2

0xA4C4

5B24

Accessor {ACCESSOR} barcode scanner with invalid VPD was detected.

Error

2

0xA4C5

5B82

Accessor {ACCESSOR} barcode scanner loopback test failed.

Error

2

0xA4C2

5B86

Accessor {ACCESSOR} could not read a frame barcode label.

Error

2

0xA4CE

5B89

Accessor {ACCESSOR} could not read an I/O station barcode label.

Informational

2

0xA4C9

5B8A

Accessor {ACCESSOR} barcode scanner communication failed

Informational

490

NA

9080

Accessor {ACCESSOR} found an empty source element.

Error

24

0xA4D0

9180

Accessor {ACCESSOR} inventory with audit failed

Error

2

0xA4D5

9181

Accessor {ACCESSOR} inventory failed

Error

2

0xA4D5

9250

Accessor {ACCESSOR} had only one usable gripper for operation.

Error

2

0xA4D2

9251

Accessor {ACCESSOR} had no usable grippers for operation.

Error

2

0xA4D2

9480

Accessor {ACCESSOR} found a destination element unexpectedly full.

Error

24

0xA4D1

A010

Cartridge {VOLSER} was not detected from the previous inventory.

Error

24

0xA950

A012

An inventory self-correction started.

Informational

24

0xA952

A080

Accessor {ACCESSOR} had no grippers installed.

Error

2

0xB420

A08C

A drive type that was incompatible with the original drive type was detected.

Error

2

0xB32C

B061

Could not lock I/O station door

Error

17

0xB091

B062

Could not unlock I/O station door

Error

17

0xB092

B063

Could not open I/O station door

Error

17

0xB093

B064

Could not close I/O station door

Error

17

0xB094

B066

A magazine type incompatible with the library was detected in an I/O Station

Warning

17

N/A

B220

Gripper {GRIPPER} could not get cartridge {VOLSER} from I/O station.

Error

17

0xB320

B221

Gripper {GRIPPER} could not put cartridge {VOLSER} in I/O station.

Error

17

0xB321

B382

Gripper {GRIPPER} could not get cartridge {VOLSER} from slot.

Error

2

0xB150

B383

Gripper {GRIPPER} could not get cartridge {VOLSER} out of slot.

Error

2

0xB152

B384

Gripper {GRIPPER} found cartridge {VOLSER} stuck in the slot

Error

2

0xB153

B388

Gripper {GRIPPER} could not put cartridge {VOLSER} in slot.

Error

2

0xB151

B480

Accessor {ACCESSOR} X or Y motion command exceeded the limits of the library

Error

4

0xAACA

B481

Accessor {ACCESSOR} asymmetrical motor limits were detected

Error

4

0xAACB

B500

Accessor {ACCESSOR} calibration failed.

Error

2

0xB190

B580

Accessor {ACCESSOR} could not find a column fiducial.

Error

2

0xB361

B581

Accessor {ACCESSOR} encountered a column tilt outside the specified operational limits

Error

493

N/A

B582

Accessor {ACCESSOR} found a column fiducial calibration value is outside the operational limits against stored value

Warning

496

N/A

B583

Accessor {ACCESSOR} found a column calibration value out of range from adjacent column

Warning

498

N/A

B584

Accessor {ACCESSOR} encountered a column tilt close to the operational limits.

Warning

506

N/A

B681

Accessor {ACCESSOR} could not find a drive fiducial.

Error

2

0xC020

B682

Accessor {ACCESSOR} found a drive fiducial calibration value is outside the operational limits against stored value

Warning

497

N/A

B790

Accessor {ACCESSOR} could not find an I/O station fiducial.

Error

2

0xB370

B791

Accessor {ACCESSOR} could not find an I/O station fiducial.

Error

2

0xB170

B792

Accessor {ACCESSOR} detected an un-calibrated frame.

Error

2

0xB171

B793

Accessor {ACCESSOR} encountered an I/O station tilt outside the specified operational limits

Error

494

N/A

B891

A drive did not release the cartridge. This failure could be caused by a cartridge gate not opening due to a gate mechanical problem.

Error

2

0xC031

B893

A drive did not load the cartridge

Error

2

0xC033

CCCA

A memory allocation or stack error occurred.

Informational

4

0xACCC

CCCC

A library firmware error occurred.

Informational

4

0xACCC

CCCF

X authorization failed.

Error

4

0xACCF