Feature codes for the TS4500
Order feature codes to install components in library frames or to enhance the capacity or capabilities of the library.
FC | Model | CSU | Description |
---|---|---|---|
1404 | L25, L55 | No | TS1140 and TS1150 tape drive support This triggers the shipment of a JK diagnostic cartridge. When model L25 is ordered or when FC 9080 (Mixed Media) is ordered for model L55, a minimum of one of FC 1404 or 1406 is required but any may be selected. |
1405 | L25, L55 | No | LTO5 and LTO6 tape drive support This triggers the shipment of an L5 diagnostic cartridge. When model L55 is ordered, a minimum of one of FC 1405 or 1407 is required but both can be selected. When FC 9080 (Mixed Media) is ordered for model L25, a minimum of one of FC 1405 or 1407 is required but both can be selected. |
1406 | L25, L55 | Both | TS1150, TS1155, or TS1160 tape drive support This feature provides a JL diagnostic cartridge. When model L25 is ordered or when FC 9080 (Mixed Media) is ordered for model L55, a minimum of one of FC 1404 or 1406 is required but any may be selected. |
1407 | L25, L55 | No | LTO6 and LTO7 tape drive support This triggers the shipment of an L6 CE cartridge. When model L55 is ordered, a minimum of one of FC 1405 or 1407 is required but both can be selected. When FC 9080 (Mixed Media) is ordered for model L25, a minimum of one of FC 1405 or 1407 is required but both can be selected. |
1408 | L25, L55 | No | LTO7 and LTO8 tape drive support This triggers the shipment of an L7 CE cartridge. When model L55 is ordered, a minimum of one of FC 1407 or 1408 is required but both can be selected. When FC 9080 (Mixed Media) is ordered for model L25, a minimum of one of FC 1407 or 1408 is required but both can be selected. |
1409 | L25, L55 | No | LTO8 and LTO9 tape drive support This triggers the shipment of an L8 CE cartridge. Only one L8 CE cartridge feature #1409 is required in a TS4500 Library. Prerequisite: One of either feature #1408 or #1409 is a prerequisite for the first TS1080 (3588 Model F8x) tape drive ordered. Feature #1409 is a prerequisite for the first TS1090 (3588 Model F9x or S9C) Tape drive ordered. |
1412 | L25, L55 | No | SAS tape drive support This feature provides a mini SAS HD wrap tool. Only one tool is required for the library. The wrap tool is used to isolate drive sled problems |
1442 | HA Kit w/Second Accessor | No | Dual Accessors This triggers the shipment of
|
1450 | D25, D55 | No | TS4500 frame control assembly
(FCA) Includes 1x LCC and 2x power supplies. |
1460 | L25, L55 | No | Redundant Accessor Power/Network This provides power and internal network redundancy for the L25/L55 frame. This is a prerequisite to FC 9002. |
1530 | D25, D55, L25, L55, S25, S55 | No | Web camera mounting hardware
Provides mounting hardware only. |
1531 | D25, D55, L25, L55 | No | First quad drive mounting kit
This feature provides signal and power cabling for a column of 4 adjacent drives. Fiber cables
can be ordered via one of the following:
Prerequisite:
|
1532 | D25, D55, L25, L55 | No | Second quad drive mounting kit This feature provides signal and power cabling for a column of 4 adjacent drives. Fiber cables can be ordered via one of the following:
This feature is not supported in the leftmost frame of a dual accessor library. Prerequisite:
|
1533 | D25, D55, L25, L55 | No | Third quad drive mounting kit This feature provides signal and power cabling for a column of 4 adjacent drives. Fiber cables can be ordered via one of the following:
This feature is not supported in the leftmost or rightmost frame of a dual accessor library. Prerequisite:
|
1534 | D25, D55, L25, L55 |
Both |
Fourth quad drive mounting kit This feature provides signal and power cabling for a column of 4 adjacent drives. Fiber cables can be ordered via one of the following:
This feature is not supported in the leftmost frame of a single accessor library. This feature is not supported in the leftmost or rightmost frame of a dual accessor library. Prerequisite:
|
1536 | D25, D55, L25, L55 | Both | MMF Quad Drive-to-Patch Panel Cables (all drive models) This feature includes all fiber cables required for a column of 4 drives, 8x LC-LC Multimode Fiber (MMF) Drive-to-Patch Panel cables. Prerequisite: One FC 1536 or 1537 or 9713 per each FC 1531, 1532, 1533, and 1534. |
1537 | D55, L55 | Both | SMF Quad Drive-to-Patch Panel Cables (LTO8) This feature includes all fiber cables required for a column of 4 drives, 8x LC-LC Single Mode Fiber (SMF) Drive-to-Patch Panel cables. Prerequisite: One FC 1536 or 1537 or 9713 per each FC 1531, 1532, 1533, and 1534. |
1604 | L25, L55 | Yes | Transparent LTO encryption
Provides license keys to enable transparent LTO encryption. |
1628 | L55 | Yes | Additional LTO Cartridge Magazines Provides magazine and cover for transport or storage of up to 18 cartridges. |
1629 | L25 | Yes | Additional 3592 Cartridge Magazine Provides magazine and cover for transport or storage of up to 16 cartridges. |
1643 | L25, L55 | Yes | Intermediate capacity on demand Provides license key to increase storage from entry capacity to intermediate capacity. |
1644 | L25, L55 | Yes | Base capacity on demand Provides license key to increase storage from intermediate capacity to base capacity. This feature code is a prerequisite for FC 9002 or Model Lx5 HD CoD FC 164x. Prerequisite: FC 1643 |
1645 | S25 | Yes | High density capacity on demand |
1646 | S55 | Yes | High density capacity on demand |
1647 | L25 | Yes | High density capacity on demand Prerequisite: FC 1644 |
1648 | L55 | Yes | High density capacity on demand Prerequisite: FC 1644 |
1649 | D25 | Yes | High density capacity on demand |
1650 | D55 | Yes | High density capacity on demand |
1652 | D25, D55 | No | Two additional I/O stations This feature code adds either 36 (LTO) or 32 (3592) I/O slots. |
1663 | D25, D55, L25, L55 | No | Drive removal |
1682 | L25, L55 | Yes | Path failover |
1742 | Sx4 | No | TS4500 Control - Upgrade This includes 1x top panel and 2x Ethernet cables, card cages, ASCs, BPCs, and LFIs. |
1750 | TR1, TR2 | No | Side covers This feature provides left-and right-side end covers. This feature is required only for the first top rack ordered (if multiple top racks are installed on adjacent frames). |
1751 | TR1 | No | Power distribution unit Provides one PDU to be mounted in the top rack. The first
PDU in a top rack does not consume any of the 10U of rack space. The second PDU in a top rack
consumes 1U of rack space.
Note:
Each PDU has 10 C13 outlets divided into 2 groups of 5 outlets. Each group is protected by a 15 amp circuit breaker. In addition, there is a master 25 amp circuit breaker for the entire PDU. All of the circuit breakers are rated at 5 kAIC. Each PDU has a control input that can be used to turn all of the outlets on or off by an external switch or relay contact (not provided). The control input is defaulted to ON by a jumper plug included with the PDU. Prerequisite: For each FC 1751 ordered, one power cord (FC 9954 through 9959 or 9966) must also be ordered. Limitation: Mutually exclusive with 1752 |
1752 | TR1, TR2 | Yes | Enhanced PDU Provides one PDU with 3-phase (wye) or single phase input power, to be mounted in top rack (max of two may be ordered). Each PDU ordered in a top rack consumes 1U of rack space. Each PDU has 9 outlets divided into three groups. Within each group there are two C-13 outlets and one C-19 outlet. Each group is protected by 20amp circuit breakers rated at 10 kAIC. Note that, if required, loads installed in the TR1 with C14 inlets can be connected to the PDU C19 outlets by use of C20 to C13 power cord FC 9949. Prerequisite:
Limitation: Mutually exclusive with FC 1751 |
1753 | TR2 | No | Olympus Rack Configuration This feature code specifies the configuration of the TR2 rack to be in conformance with the Open Compute Project Olympus Rack Specification. This provides 5U of 19 inch rack space with 3 sets of EIA rails with a spacing from the front face of the front EIA rail to the rear face of the middle EIA rail being 745 mm and the spacing from the front face of the front EIA rail to the rear face of the rear EIA rail to be 1020 mm. It includes a top cover that allows top access cables to be routed into the TR2. This also includes side air blocks that prevent airflow between the EIA rails and the side covers per the Open Compute Olympus Rack Specification |
1754 | TR2 | No | Standard 19 inch Rack Configuration This feature code specifies the configuration of the TR2 rack to be in conformance with industry standard 19 inch racks. This provides 5U of 19 inch rack space with 2 sets of EIA rails with a spacing from the front face of the front EIA rail to the rear face of the rear EIA rail being 719 mm. It includes a top cover that allows top access cables to be routed into the TR2. |
1755 | TR2 | Yes | Front Door This feature provides the front door for the TR2 |
1756 | TR2 | Yes | Rear Door This feature provides the rear door for the TR2 |
1802 | L25, L55 | No | 1- to 2-frame X-track cable Non-HA 1 to 2 Frame Track Cable |
1806 | L25, L55 | No | 3- to 6-frame X-track cable Non-HA 3 to 6 Frame Track Cable |
1814 | L25, L55 | No | 7- to 14-frame X- track cable Non-HA 7 to 14 Frame Track Cable. See 3584 X Track Cable Features/Specify codes for more details. Limitation: Not supported with FC 2071 or FC 9071. |
1818 | L25, L55 | No | 9- to 18-frame X- track cable Non-HA 9 to 18 Frame Track Cable. See 3584 X Track Cable Features/Specify codes for more details. Limitation: Not supported with FC 2071 or FC 9071. |
1909 | L25, L55, D25, D55 | No | Single power source bifurcated cable
Allows attachment of a powered frame to a single outlet while also maintaining drive redundant power. |
1951 | D25, D55, L25, L55, S25, S55 | No | Power distribution units
Provides two PCAs, mounting hardware including rack brackets, and internal power cables. Supports any combination of up to 3 pairs of power cords for FC 4875 on the same frame and FC 9989 on adjacent frames. Each PDU has 10 C13 outlets divided into 2 groups of 5 outlets. Each group is protected by a 15 amp circuit breaker. In addition, there is a master 25 amp circuit breaker for the entire PDU. All of the circuit breakers are rated at 5 kAIC. Each PDU has a control input that can be used to turn all of the outlets on or off by an external switch or relay contact (not provided). The control input is defaulted to ON by a jumper plug included with the PDU. Corequisite: One power cord feature (FC 9954 through 9959 or 9966) Limitation: FC 1951 cannot be installed in the same rack as an FC 1952 PDU. |
1952 | D25, D55, L25, L55, S25, S55 | No | Enhanced PDUs Provides two PDUs with 3-phase (wye) or single phase input power, mounting hardware including rack brackets, and internal power cables to provide power to the local frame control assembly. These line cord features may require different customer facility outlets than frames without FC 1952. Can be used for adjacent frame AC power cord aggregation, or for unique facility AC socket requirements. Supports any combination of up to 3 pairs of power cords for FC 9989 on adjacent frames. Each PDU has 9 outlets divided into three groups. Within each group there are two C-13 outlets and one C-19 outlet. Each group is protected by 20amp circuit breakers rated at 10 kAIC. Note that, if required, loads installed in the TR1 with C14 inlets can be connected to the PDU C19 outlets by use of C20 to C13 power cord FC 9949. Prerequisite:
Limitation:
|
2002 | L25, L55 | No | 1-2 Frame Flex Track A Cable |
2006 | L25, L55 | No | 3-6 Frame Flex Track A Cable |
2014 | L25, L55 | No | 7-14 Frame Flex Track A Cable |
2018 | L25, L55 | No | 9-18 Frame Flex Track A Cable |
2071 | L25, L55 | No | Flex Track Guide This includes AXY, AXY plate, ASC to Flex track cable, and new end stops. |
2072 | D25, D55, S25, S55, Sx4 | No | Flex Track Guide for Expansion Frame |
2309 | xx5 | No | TS4500 Accessor Refresh Provides a complete accessor assembly with HD grippers to Lxx models or models with FC 1442. Prerequisite: FC 2071, 2072, or 9071, 9072. |
2402 | L25, L55 | No | 1-2 Frame Flex Track B Cable |
2406 | L25, L55 | No | 3-6 Frame Flex Track B Cable |
2414 | L25, L55 | No | 7-14 Frame Flex Track B Cable |
2418 | L25, L55 | No | 9-18 Frame Flex Track B Cable |
2704 | L25, L55 | No | Console expansion 26-port Ethernet switch/rack mount Provides a 26-port Ethernet switch and attachment cable for connection to an IMC as a centralized system console. Up to 24 extra connections of FC 2715 are provided by this feature. This feature is supported on Lx5 models to allow other products to share the IMC. |
2715 | L25, L55 | No | TSSC attachment cable FC 2715 is a cable to attach a unit to the Ethernet switch provided by the TSSC. Note: A maximum of 43 of
FC 2715 can be included in a single TSSC
facility.
Note: FC 2704 is supported on Lx5 models if you are connecting the frame to an
existing TSSC.
|
2735 | L25, L55 | No | USB Optical Drive Required for all new plant orders. Provides a USB optical drive for use with the Integrated Management Console (IMC). The optical drive is required for IMC code. |
2737 | S25, S55 | No | IMC Separate Power Source This feature allows longer distances between the IMC end panel and an FCA by supplying 2 Ethernet cables that are longer than normal. For both plant and field, instructions are also provided for moving the IMC PDU from another frame into this frame. Prerequisite: One of the FC 9970-9985, 9989 power cords. |
4879 | L25, D25, TR1, TR2 | No | TS7700 BE Switch Mounting Hardware Provides 2x Fibre channel switch mounting hardware, including rack brackets and power cords. Prerequisite: FC 4880 |
4880 | L25, D25, TR1, TR2 | No | TS7700 BE 16 Gb Switch Provides 1x Fibre channel switch (16 Gb). Limitation: There is a maximum of 2x FC 4880 per model x25. |
4890 | L25 | Preloaded Media Enablement Kit This feature provides the brackets and accessories for a system integrator to pre-load media. Prerequisite: FC 9074 |
|
4892 | D25, D55, L25, L55, S25, S55 | No | Rear Door Sensor This feature provides rear door sensor components for notifying of rear door open/close events. Prerequisite: FC 9074 |
6013 | D25, D55, L25, L55 | Yes | LC to LC Fibre Channel cable - 13m (43 ft) |
6025 | D25, D55, L25, L55 | Yes | LC to LC Fibre Channel Cable - 25m (82 ft) |
6061 | D25, D55, L25, L55 | Yes | LC to LC Fibre Channel Cable - 61m (200 ft) |
8750 | D55, L55 | No | LTO cleaning cartridge Universal cleaning cartridge. |
8802 | D25, L25 | No | 3592 cleaning cartridge |
9001 | D25, D55, L25, L55 | No | Driveless frame |
9002 | L25, L55 | No | First expansion frame attachment Used as a part of the process to add any Dxx or Sxx frame. Prerequisites:
|
9003 | L25, L55 | No | Additional expansion frame attachment Used as a part of the process to add any Dxx or Sxx frame. |
9040 | High Availability Library | Lx5 |
Prerequisites: One Flex-track A and B cable of the same length. Flex-Track A cable: FC 2002, 2006, 2014, or 2018. Flex-Track B Cable: FC 2402, 2406, 2414, or 2418. |
9071 | L25, L55 | No | Flex Track Guide Base Includes AXY, AXY plate, ASC to Flex track cable, and new end stops. |
9072 | D25, D55, S25, S55, Sx4 | No | Flex Track Guide for Expansion Frame |
9073 | D25, D55, L25, L55, S25, S55 | No | Gen-2 Frame This feature indicates that the frame is capable of supporting Enhanced PDUs and their associated power cords. FC 9073 is a prerequisite for ordering FC 1952. |
9074 | D25, D55, L25, L55, S25, S55 | No | Gen-3 Frame This feature indicates the frame includes third generation modifications to support future enhancements. |
9080 | L25, L55 | No | Mixed Media Library Prerequisite: Library must contain a mix of LTO and 3592 frames.
Limitation: Mixed media not supported for Lx2/Lx3. |
9210 | L25, L55 | No | Attached to HP-UX system |
9211 | L25, L55 | No | Attached to Solaris system |
9212 | L25, L55 | No | Attached to Windows system |
9213 | L25, L55 | No | Attached to other non-IBM system |
9215 | L25, L55 | No | Attached to Linux® system |
9217 | L25, L55 | No | Attached to LM/TS7700 |
9218 | L25, L55 | No | Attached to HPSS |
9400 | L25, L55 | No | Attached to i5/OS or OS/400 system |
9600 | L25, L55 | No | Attached to AIX system |
9607 | D55, L55 | No | 3588 F7A/F7C tape drive - plant install This feature informs the plant to install one LTO 7 Tape Drive Model F7A/ F7C (3588 Model F7A or F7C) into a Tape Library Model D55, or L55 coming from the plant. Prerequisites:
|
9609 | D55, L55 | No | 3588 F8A/F8C tape drive - plant install This feature informs the plant to install one LTO 8 Tape Drive Model F8A/F8C (3588 Model F8A or F8C) into a Tape Library Model D55, or L55 coming from the plant. Installation of a 3588 Tape Drive canister requires that a Quad Drive Mounting Kit feature (FC 1521, 1522, 1523, 1524 or 1531, 1532, 1533, 1534) be installed in the TS4500 frame to contain the canister. Prerequisite:
Note: One FC 1408 is required per Tape Library if this is the first LTO 8 (3588 Model F8A,
F8C, or F8S) tape drive ordered.
|
9611 | D55, L55 | No | 3588 F8S tape drive - plant install This feature informs the plant to install one LTO 8 Tape Drive Model F8S (3588 Model F8S) into a Tape Library Model D55 or L55 coming from the plant. Prerequisite:
Note: One FC 1408 is required per Tape Library if this is the first LTO 8 (3588 Model F8A,
F8C, or F8S) tape drive ordered.
|
9613 | D55, L55 | No | 3588 F9C Drive Plant Install This feature informs the plant to install one TS1090 Tape Drive Model F9C (3588 Model F9C) into a new TS4500 Tape Library Model D55 or L55 coming from the plant. Prerequisite:
Note: One feature #1409 is required per Tape Library if this is the first TS1090 (3588
Model F9S, F9C or S9C) tape drive ordered.
|
9615 | D55, L55 | No | 3588 F9S Drive Plant Install This feature informs the plant to install one TS1090 Tape Drive Model F9S (3588 Model F9S) into a new TS4500 Tape Library Model D55 or L55 coming from the plant. Prerequisite:
Note: One feature #1409 is required per Tape Library if this is the first TS1090 (3588
Model F9S, F9C or S9C) tape drive ordered.
|
9617 | D55, L55 | No | 3588 S9C Drive Plant Install This feature informs the plant to install one TS1090 Tape Drive Model S9C (3588 Model S9C) into a new TS4500 Tape Library Model D55 or L55 coming from the plant. Prerequisite:
Note: One feature #1409 is required per Tape Library if this is the first TS1090 (3588
Model F9S, F9C or S9C) tape drive ordered.
|
9677 | D25, L25 | No | Plant Install 3592 in a 3584 Frame This specify code notifies the plant to factory install a new 3592 Tape Drive into a new 3584 Tape Library Frame coming from the plant. This code must appear on the tape drive order and also the Plant Install 3592 E05 in a 3584 feature (FC 9680) or Plant Install 3592 E06 in a 3584 feature (FC 9683) or Plant Install 3592 E07/EH7 in a 3584 feature (FC 9692) or Plant Install 3592 E08/EH8 in a 3584 feature (FC 9699) or Plant Install 3592 55E in a 3584 feature (FC 9704) or Plant Install 3592 55F/55G in a 3584 feature (FC 9705) or Plant Install 3592 60F in a 3584 feature (FC 9706) or Plant Install 3592 60E in a 3584 feature (FC 9707) or Plant Install 3592 60S in a 3584 feature (FC9708) must appear on the 3584 Frame order. |
9689 | D25, L25 | Yes | Field Install 3592 in a 3584 Frame This feature notifies the plant to ship one 3592 Tape Drive, which will be field installed in a 3584 Tape Library Frame. This code must appear on the tape drive order and also the Field Merge 3592 Tape Drive (FC 1674) or (FC 1675) or (FC 1676) for a 3592 E07/E08/55G/60G, (FC 9690) for a 3592 EH7/EH8/55E/55F or (FC 9726) for a 3592 60E/60F/60S must appear on the 3584 Tape Library Frame order. |
9690 | D25, D55, L25, L55 | Both | LTO, TS1140, TS115x - field install drive in 3584 This feature field installs one 3592 Model EH7, EH8, 55E or 55F. Or one 3588 Model F5C, F6C, F7C, F8C, F8S Tape Drive into an installed 3584 Model D25 or L25, or D55 or L55. This feature is also required to field merge a 3592 Model EH7, EH8, 55E, 55F, or 3588 Model F5C, F6C, F7C, F8C, F8S Tape Drive into a 3584 frame coming from the plant. The Tape Drive requires a Quad Drive mounting kit to contain the drive. Prerequisite:
|
9692 | L25, L55 | No | 3592 E07/EH7 tape drive - plant install in 3584 FC 9692 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit). Each FC 152x supports up to 4 of FC 969x. |
9695 | L25, L55 | No | 3588 F5A/F5C tape drive - plant install in 3584
FC 9695 is a manufacturing routing code. Prerequisite: FC 152x/153x (drive mounting kit). Each FC 152x/153x supports up to 4 of FC 969x. |
9697 | D55, L55 | No | 3588 F6A/F6C tape drive - plant install FC 9697 is a manufacturing routing code. Prerequisite: FC 152x/153x (drive mounting kit). Each FC 152x/153x supports up to 4 of FC 969x. |
9699 | D25, L25 | No | 3592 E08/EH8 tape drive - plant install in 3584 FC 9699 is a manufacturing routing code. Prerequisite: FC 152x (drive mounting kit). Each FC 152x supports up to 4 of FC 969x. |
9700 | D25, D55, L25, L55 | No | No host attach cables - from plant |
9704 | D25, L25 | No | 3592 55E tape drive - Plant Install in 3584 |
9705 | D25, L25 | No | 3592 55F tape drive - Plant Install in 3584 |
9706 | D25, L25 | No | 3592 60F tape drive - Plant Install in 3584
This feature tells the plant to install one 3592 Tape Drive Model 60F into a 3584 Model D25 or Model L25 coming from the plant. Prerequisite: Installation of the 3592 Model 60F Tape Drive requires a Quad Drive mounting kit to contain the drive. Mounting Kit feature (FC 1515) or (FC 1535). |
9707 | D25, L25 | No | 3592 60E tape drive - Plant Install in 3584
This feature tells the plant to install one 3592 Tape Drive Model 60E into a 3584 Model D25 or Model L25 coming from the plant. Prerequisite:
|
9708 | D25, L25 | No | 3592 60S tape drive - Plant Install in 3584 This feature tells the plant to install
one 3592 Tape Drive Model 60S into a 3584 Model D25 or Model L25 coming from the plant.
Note: TS1160
Tape Drive Model 60S must be separately ordered and FC 9677 must be specified on that
drive
Prerequisite:
|
9713 | D25, D55, L25, L55 | Both | No Patch Panel Cables This feature should be specified if you do not want the factory to ship any Fiber Channel cable FC 1536 “MMF Quad Drive-to-Patch Panel cables” or FC 1537 “SMF Quad Drive-to-Patch Panel cables”. |
9726 | L25, D25 | Both | TS1160 tape drive - Field Install Drive in 3584 This feature field installs one 3592 Model 60E or 60F or 60S Tape Drive into an installed 3584 Model D25 or L25. This feature is also required to field merge a 3592 Model 60E or 60F Tape Drive into a 3584 frame coming from the plant. Prerequisite:
|
9735 | L25, L55 | No | IMC broadband Call Home This feature originally indicated that the customer would allow broadband Call Home; however, the feature code is no longer utilized. |
9948 | D25, D55, L25, L55, S25, S55, TR1, TR2 | Both | 3 Phase Power Cord
This feature provides a 4.3 meter (14 foot) long power cord with an IEC 309 3P+N+G 32A plug, rated for 230 Vac, 24 Amps. This power cord supports 3 phase (wye) power. To be used with Enhanced PDU FC 1752 or 1952. |
9949 | D25, D55, L25, L55, S25, S55, TR1, TR2 | Both | C20-C13 Power Cord for spare outlets in the Enhanced PDU
This feature provides a 2.8 meter long C20-C13 Power Cord to be used between computer equipment and the Enhanced PDU FC 1752 or 1952 or customer-supplied PDU with C19 outlets. C13 connects to the male C14 inlet or power cord plug and the C20 mates with the C19 receptacle on the Enhanced PDU. This power cord is intended to be used on PDUs with C19 outlets. |
9954 | D25, D55, L25, L55, S25, S55, TR1, TR2 | No | NEMA L6-30 Power Cord FC 9954 is used with PDU FCs 1751 and 1752 (in model TR1) or 1951 and 1952 (in model xx5). FC 9954 provides 1x power cord when ordered on a model TR1 and 2x power cords when ordered on a model xx5. |
9955 | D25, D55, L25, L55, S25, S55, TR1, TR2 | No | RS 3750DP power cord FC 9955 is used with PDU FC 1751 and 1752 (in model TR1) or 1951 and 1952 (in model xx5). FC 9955 provides 1x power cord when ordered on a model TR1 and 2x power cords when ordered on a model xx5. |
9956 | D25, D55, L25, L55, S25, S55, TR1, TR2 | No | IEC 309 power cord FC 9956 is used with PDU FC 1751 and 1752 (in model TR1) or 1951 and 1952 (in model xx5). FC 9956 provides 1x power cord when ordered on a model TR1 and 2x power cords when ordered on a model xx5. |
9957 | D25, D55, L25, L55, S25, S55, TR1, TR2 | No | PDL 4.3m power cord (Australia/NZ)
FC 9957 is used with PDU FC 1751 and 1752 (in model TR1) or 1951 and 1952 (in model xx5). FC 9957 provides 1x power cord when ordered on a model TR1 and 2x power cords when ordered on a model xx5. |
9958 | D25, D55, L25, L55, S25, S55, TR1, TR2 | No | 4.3m power cord (Korea) FC 9958 is used with PDU FC 1751 and 1752 (in model TR1) or 1951 and 1952 (in model xx5). FC 9958 provides 1x power cord when ordered on a model TR1 and 2x power cords when ordered on a model xx5. |
9959 | D25, D55, L25, L55, S25, S55 | No | Unterminated power cord FC 9959 is used with PDU FC 1751 (in model TR1) or 1951 (in model xx5). FC 9959 provides 1x power cord when ordered on a model TR1 and 2x power cords when ordered on a model xx5. Limitation: Not supported with FC 1752 or 1952. |
9966 | D25, D55, L25, L55, S25, S55 | No | Unterminated power cords (China CCC cert) FC 9966 is used with PDU FC 1751 (in model TR1) or 1951 (in model xx5). FC 9966 provides 1x power cord when ordered on a model TR1 and 2x power cords when ordered on a model xx5. Limitation: Not supported with FC 1752 or FC 1952. |
9970 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cord (international, 250 VAC 16A single phase, watertight connector,
IEC-309) FC 9970 includes model-dependent contents. For countries other than the United States and Canada, the connector is rated at 16A (plug type Hubbell HBL316P6W or equivalent) for connection to Hubbell type HBL316R6W or equivalent receptacles. In the United States and Canada, the connector is rated at 20A (plug type Hubbell HBL320P6W) for connection to Hubbell type HBL320R6W or equivalent receptacles. This is the default power cord for all countries other than those specified for FC 9972 and FCs 9976 through 9983. This power cord can be used for all countries
except:
Note: Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC
2737.
|
9972 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords, 250 VAC 15, non-watertight twist lock connector, Nema L6-15P mates
with L6-15R FC 9972 includes model-dependent contents. It is the default power cord for US, Canada, Japan, Korea, Philippines, and Taiwan. Note: Only 1 power cord is shipped for an S25 and
S55 to be used in conjunction with FC 2737.
|
9976 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 10 Amp/250 Vac, non watertight IRAM 2073 plug
(Argentina) Note: Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with
FC 2737.
|
9977 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 15 Amp/250 Vac with earth pin InMetro NBR 14136 plug
(Brazil) Note: Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC
2737.
|
9978 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 10 Amp/250 Vac Aust/NZS 3112/2000 plug (Australia and New
Zealand) Note: Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC
2737.
|
9979 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 15 Amp/250 Vac JIS C8303, C8306 plug (Japan) Note: Only 1
power cord is shipped for an S25 and S55 to be used in conjunction with FC 2737.
|
9980 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 10 Amp/250 Vac, GB 2099.1, 1002 plug (China) Note: Only 1
power cord is shipped for an S25 and S55 to be used in conjunction with FC 2737.
|
9981 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 15 Amp/250 Vac with earth pin KS C8305, K60884-1 plug
(Korea) Note: Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with FC
2737.
|
9982 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 10 Amp/250 Vac CNS 10917-3 plug (Taiwan) Note: Only 1 power
cord is shipped for an S25 and S55 to be used in conjunction with FC 2737.
|
9983 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 10 Amp/250 Vac SANS 164-1 plug (South Africa) Note: Only 1
power cord is shipped for an S25 and S55 to be used in conjunction with FC 2737.
|
9984 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 15 Amp/250V single phase power cord assemblies, NEMA L6-20P
non-watertight twistlock 20A plug FC 9984 is 2x power cords which are UL / CSA certified for use in US and Canada. These power cords mate with customer-supplied NEMA L6-20R receptacles. Note: Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with
FC 2737.
|
9985 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 15 Amp/250V single phase power cord assemblies with watertight
15A Russellstoll plug FC 9985 is 2x power cords which are UL/CSA certified for use in US and Canada. These power cords mate with customer-supplied Russellstoll 3743U2 or 9R23U2W receptacles. Note: Only 1 power cord is shipped for an S25 and S55 to be used in conjunction with
FC 2737.
|
9989 | D25, D55, L25, L55, S25, S55 | No | Dual 4.3m power cords with 10Amp/250V with IEC 309 C14 plug FC 9989 is for use with adjacent frame PDUs (FC 1951) or external (customer-supplied) PDUs. Note: Only 1 power cord is
shipped for an S25 and S55 to be used in conjunction with FC 2737.
|
AGKA | D25, D55, L25, L55 | Yes | 3m Mini-SAS HD/Mini-SAS HD Cable 3meters Mini-SAS HD to Mini-SAS HD cable for attachment of up to four Tape Drives in the same column. Prerequisite:
|
AGK1 | D25, D55, L25, L55 | Yes | 10 Meter OM3 Fiber Cable (LC) Provides a 10m fiber cable to connect a drive to a switch that is external to the tape library. This cable can also be used to connect to a TS7700 back-end fiber switch that is 2 to 3 frames away.Order the number of this feature code for each drive to be connected. |
AGK2 | D25, D55, L25, L55 | Yes | 25 Meter OM3 Fiber Cable (LC) Provides a 25m fiber cable to connect drives to a fiber switch that is external to the tape library.Order the number of this feature code for each drive to be connected. |
AGK3 | D25, D55, L25, L55 | Yes | 80 Meter OM3 Fiber Cable (LC) Provides an 80m fiber cable to connect drives to a fiber switch that is external to the tape library.Order the number of this feature code for each drive to be connected. |
AGKQ | D25, D55, L25, L55 | Yes | 3 Meter OM3 Fiber Quad Cables (LC) Provides 2 space-efficient 3m bundles (of four cables each) to connect four drives to a fiber switch in the same or one frame away, or in a Top Rack.To attach tape drives in the same frame or 1 frame away from a model x25 frame containing TS7700 BE switches, order one of this feature code for each quad-drive mounting kit to be connected. For xx5 models, each FC AGKQ has a prerequisite of an associated FC 152x or 153x. |