Using the web to remove a cleaning cartridge from the library
Complete this task to remove a cleaning cartridge from the library using the web.
About this task
To use the Tape Library Specialist web interface
to remove a cleaning cartridge from the TS3500 tape library, perform
the following steps:
- From the Work Items navigation pane, select . The Cleaning Cartridges screen displays.
- Select a cleaning cartridge. Then, from the Select Action drop-down list, select Remove. Click Go.
- Look at the Activity screen on the operator panel to determine whether the I/O station that you want to use is locked or unlocked. If the station is locked, use your application software to unlock it.
- Open the door of the I/O station and remove the cleaning cartridge.
- Close the door of the I/O station.