Host storage sensor
The host storage sensor discovers the storage that is attached to a host computer system, including storage area network (SAN) storage. This sensor extends the storage discovery that is provided by the storage sensor.
The host storage and storage sensors discover the same storage resources, for example, disks, partitions, logical volumes, physical volumes, and file systems. The host storage sensor also discovers the following storage resources:
- Fibre Channel (FC) volumes
- FC ports
- Host bus adapters
Sensor name that is used in the GUI and logs
HostStorageSensor
Prerequisites
- For 64-bit Linux targets
-
The
32-bit glibc
library is required, only when 32-bit version ofcollectionEngine
binary is used by the sensor (Default).If
collectionEngineBuild_64_Bit
option is set to true, then32-bit glibc
is not required but 64-bit glibc is required.
Limitations
When you discover storage attached to a target computer using the storage sensor, do not carry out a discovery on the same system using this sensor.
You must install Vendor's host bus adapter (HBA) API library files (32-bits). Instead of 32 bit, vendor's 64-bit HBA API library files are required when sensor uses 64-bit collection engine binary.
The sensor does not discover the ZFS file systems on the Solaris target systems.
Do not run the sensor on AIX LPARs, where the LPAR's configuration is attached to the BR8470 FCoE switch that runs FOS v6.4.3_dcb in Access Gateway mode. It leads to an unexpected behavior of systems that are connected to that FC Switch. Use FOS7.0.2e, or later.
Security issues
By default, root user privileges
are required to discover SAN resources in UNIX environments. Typically, this escalation
is done by setting the file access permissions using the setuid
(set-user-ID