HAngeul subcommand—Change the data transfer type to HANGEUL
Purpose
Use the HAngeul subcommand to change the data transfer type to Hangeul.
MVS™ FTP uses the same SBCS translate table for single-byte or double-byte data transfers. If you require an alternate SBCS table for a double-byte transfer, use the SIte/LOCSIte SBDataconn or SIte XLate subcommand to have the server (or client) change the SBCS translation for the data connection.
Format
Parameters
- Sosi
- Transferred data contains the shift-out and shift-in characters
specified by one of the following parameters – Ascii, Ebcdic
or Space. If no parameter is specified, ASCII is used as the default.
If Sosi is not specified at all, shift-out or shift-in characters are not used in the transferred data.
- Ascii
- When combined with the Sosi parameter, causes shift-out and shift-in characters X'1E' and X'1F' to be used to delimit DBCS strings in ASCII data.
- Ebcdic
- When combined with the Sosi parameter, causes shift-out and shift-in characters X'0E' and X'0F' to be used to delimit DBCS strings in ASCII data.
- Space
- When combined with the Sosi parameter, causes shift-out and shift-in characters X'20' and X'20' (ASCII spaces) to be used to delimit DBCS strings in ASCII data.
- NOSo
- Specifies that the data transferred is pure DBCS (data with no SBCS characters) and is to be transferred to or from EBCDIC DBCS data that contains no shift-out or shift-in delimiters.
- NOType
- Suppresses the sending of the corresponding TYpe command to the server. Use this parameter when translation is to be done by the FTP client only.
Usage
The HAngeul client subcommand is equivalent to the TYPE B 5 server command.
Context
See FTP with traditional DBCS support for more information.