IEC161I (return code 128) rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat
Explanation
For general information about message IEC161I, see the explanation for return code 001.
Specific information for this return code: CLOSE processing for WRTBFR detected an error.
SFI Hex Value | Description |
---|---|
X'000C0004' | Indicates the whole RPL feedback word that can be use to locate the error point of VSAM Record Management failure. |
System action
CLOSE processing ends for the data set. CLOSE (TYPE=T operand) processing continues. The error flag (ACBERFLG) in the ACB (access method block) for the data set is set to 184 (X'B8').
Programmer response
If the error occurred during CLOSE or CLOSE (TYPE=T) processing, correct the error and rerun the job.
Module
IDA0200B, IDA0231B
Routing code
11
Descriptor code
6