IEC161I (return code 033) rc[(sfi)]-ccc,jjj, sss,ddname,dev,ser,xxx, dsname,cat
Explanation
For general information about message IEC161I, see the explanation for return code 001.
Specific information
for this return code: Cannot extend the catalog. The catalog has reached
the maximum number of extends. Either additional space is unavailable
or a system error occurred. The (sfi) field in the message is of
the form (rc, crs, cmi) where
- rc - catalog return code
- crs - catalog reason code
- cmi - catalog module name that detected the error
See message IDC3009I for a list of these catalog return and reason codes.
System action
EOV processing ends for the data set.
Programmer response
The access method services DELETE command can be used to delete entries from the catalog. If no entries can be deleted, the access method services EXPORT command can be used to move some of the data sets defined in the full catalog to a portable volume. The IMPORT command can be used to define the exported data sets in a user catalog that has space available.
Module
IDA0557A, IDA0557B, IDAV557A
Routing code
11
Descriptor code