IEC908I 112,rc,jjj,sss,ddname
Explanation
Incorrect input was passed to SVC 18 by the BLDL or FIND macro instruction.
In the message text:
- rc
- Associates this message with system completion code 112 and with the return code.
- jjj
- Job name.
- sss
- Step name.
- ddname
- DDname, if a valid DCB in the user's region was passed to SVC 18; or SYSDCB, if a DCB address of 0, an incorrect DCB, or the address of the system LINKLIB or SVCLIB DCB was passed to SVC 18.
The explanation for the hex return code is as
follows:
- Return Code
- Explanation
- 01
- Parameter list not in caller's storage.
- 02
- DCB not in caller's storage.
- 03,13
- DCB does not point to a valid DEB. If rc is 13, the DCB is dumped to the GTF data set.
- 04,14
- A program check occurred in the POINT routine. If rc is 14, the DCB is dumped to the GTF data set.
System action
An attempt is made to trace the DCB to the GTF trace data set. The task is ended.
Operator response
Start a generalized trace facility (GTF) trace,
and re-create the problem. Reply to message AHL100A with:
TRACE=SYS,USR,SLIP
On
the DD statement for the data set in error, specify:
DCB=DIAGNS=TRACE
System programmer response
If the error recurs and the program is not in error, look at the messages in the job log for more information. Search problem reporting data bases for a fix for the problem. If no fix exists, contact the IBM® Support Center. Provide the program listing for the job.
Programmer response
Probable user error. Correct the BLDL or FIND macro instruction. For return codes 03, 13, 04, and 14, make sure that the DCB is not being overlaid, in particular the fields DCBDEBAD and DCBPOINT. Recompile the program and rerun the job.
Source
DFSMSdfp
Module
IGCT0018
Routing code
11
Descriptor code
6