IEC705I TAPE ON dev,ser [IS] [,labtyp],den BPI [,jjj,sss] [,dsname] TAPE ON dev,ser [IS] [,labtyp],trtch [,jjj,sss] [,dsname] [,mediatype] [,LOGICAL WORM]
Explanation
The volume label of the tape volume whose serial number is ser, on device dev, has been rewritten to conform to the label type indicated by labtyp: either SL, AL, or NSL and to the density indicated by den. For NL, this message is only issued if the tape formerly contained labels which have now been written over. If the tape was originally NL and is now still NL, this message is not issued.
In the message
text:
- trtch
- Indicates the recording mode as COMP (compaction for hardware) or NOCOMP (non-compaction for hardware).
- jjj
- Indicates the job requesting the volume.
- sss
- Indicates the job step requesting the volume.
- dev
- The device number of the specified device.
- ser
- The volume serial number.
- labtyp
- The label type.
- den
- The density.
- dsname
- The data set name.
- mediatype
- The media type.
If a MONITOR DSNAME command is active, dsname may appear and indicates the data set requesting the volume.
This
message is issued only when the volume label of a tape is rewritten,
which means that it is issued only for the first data set written
onto an output tape volume. The following example describes when
message IEC705I is issued when creating a tape multi-data set, multi-volume
collection:
- Start of data set 1 on volume 1 - IEC705I is issued.
- Continuation of data set 1 onto volume 2 - IEC705I is issued.
- Start of data set 2 on volume 2 - IEC705I is not issued.
- Continuation of data set 2 onto volume 3 - IEC705I is issued.
System action
The job step continues processing.
Operator response
Record the indicated information for use of the volume in conjunction with subsequent requests.
System programmer response
None
Source
DFSMSdfp
Module
IFG0194F
Routing code
3,5
Descriptor code
4