IEC205I ddname,jobname,stepname,FILESEQ = nnn, COMPLETE VOLUME LIST | EXTEND VOLUME LIST, [DSN=dsn,] VOLS=volser, [number ADDITIONAL VOLS,] [LISTED VOL(S) HAVE BEEN DATA ENCRYPTED.KL1CD:L|H KL2CD:L|H, KL1=keylable1,KL2=keylabel2 TOTALBLOCKS=mmm,] [3490 EMULATION VOLUMES EXTENDED CAPACITY MODE|3490 EMULATION VOLUMES EXTENDED CAPACITY USED,] [PERFORMANCE SEGMENTED | PERFORMANCE SCALED]
Explanation
The program has successfully written to the volume or volumes whose serial numbers are listed after VOLS=. This volume list is either the complete volume list for the data set dsn after DSN= or the list of volumes to which the data set has been extended. This volume list might be a subset of the volume serial numbers specified in the DD statement and in message IEF285I. If applicable, this message indicates either that you requested extended capacity mode for emulation of the IBM® 3490 or that data blocks were written in the extended capacity area of one or more of the listed volumes.
In the message text:
- ddname
- The data definition name.
- jobname
- The job name.
- stepname
- The step name.
- nnn
- The decimal file sequence number of the tape data set that was created or extended.
- dsn
- The data set name.
- volser
- A list of volume serial numbers. The message lists up to eight
volume serial numbers per line. If there are more than eight volume
serial numbers in the message, there will be additional lines in the
message until all the volume serial numbers have been listed. Each
new line of volume serial numbers begins with VOLS=.The volume serial list might be followed by the text, number ADDITIONAL
VOLS.
- number
- A value between 1 and 245 (inclusive) that identifies the number of any additional volumes.
- mmm
- The decimal multivolume total of data blocks for a data set. TOTALBLOCKS is omitted when a multivolume data set is extended starting on a volume other than the data set's first volume. It will also be omitted if the access method being used by the application isn't maintaining the block count in the DCB such as may be the case for the EXCP access method.
System action
Processing continues.
Operator response
None
System programmer response
None
Programmer response
When the extended capacity area of the volume or volumes is used, subsequent access of the data set on a 3590 device in 3490-E emulation might require the application to request extended capacity mode through the CAPACITYMODE=XCAP parameter of the DCBE macro.
Source
DFSMSdfp
Module
IFG0194J