Parameter Description for D OPTsdef

CKPTOPT
Displays which checkpoint data set JES2 read as the source for building the JES2 work queues during the last restart.
Start of changeCOLD_START_MODEEnd of change
Start of changeSpecifies the checkpoint mode ($ACTIVATE LEVEL) for JES2 to use for COLD starts (Z11, Z22, NULL).End of change
CONSOLE
Displays the value of the CONSOLE option.
HASPPARM
Displays the name of the data definition (DD) statement that defines the data set containing the initialization statements that JES2 is to use for initialization.
LIST
Displays whether or not JES2 lists the current and subsequent initialization statements on the printer defined by the HASPLIST DD statement.
LISTOPT
Displays the value of the LISTOPT start option.
LOG
Displays whether or not JES2 copies subsequent initialization statements to the printer specified by the HASDCPY console.
LOGOPT
Displays the value of the LOGOPT start option which specifies whether or not JES2 logs the initialization statements to a device (if specified).
RECONFIG
Displays the value of the RECONFIG start option which specifies whether the operator can specify RECONFIG to override any/all previous checkpoint forwarding.
REQMSG
Displays the value of the REQ|NOREQ start option which specifies whether JES2 issues the $HASP400 ENTER REQUESTS message.
SPOOL
Displays whether this member performed a spool validation on its last restart, and whether validation was forced.
STARTOPT
Displays the type of start that was specified in the initialization options (FORMAT, COLD, WARM).
STARTYPE
Displays the type of start that was actually performed (FORMAT, COLD, ALL-MEMBER WARM, SINGLE-MEMBER WARM, QUICK, HOT).