CFCN entry for coupling facility connection service (Part 1)

Entry:
CFCN
VIT option:
CFS
Event:
Invocation of the MVS™ macro IXLCONN
VIT processing module:
ISTRACCF
Control is returned to:
ISTFSGCN
This trace record is written when there is an attempted connection to the coupling facility structure with the IXLCONN macro.
REQTEXT
Byte (hex)
Contents
00–03
Record ID: C"CFCN"
04
ID is the primary address space ID (ASID). This field is 0 if the ASID is greater than X'FF'.
05
Event flags:
Bit
Meaning
1... ....
The rebuild process is in progress for the structure.
.1.. ....
The rebuild stop process is in progress for the structure.
..1. ....
This connection attempt caused the structure to be allocated.
...1 ....
A previously failed connection has been reestablished.
.... 1...
Full connectivity to the rebuild structure cannot be obtained. This bit is valid only if this connection attempt caused the structure to be allocated. This bit is set only if IXLCONN was invoked during rebuild processing.
... .1..
The structure involved is volatile.
... ..1.
VTAM® did not process this event.
... ...x
0
06
0
07
Connection identifier or 0. If IXLCONN was successful, this field contains the connection identifier assigned to this connection. Otherwise this field contains the value 0.
08–0B
Structure object (CFSSTR) address
0C–0F
0
10–13
The address of the invoker of IXLCONN
14–17
Return code for the MVS macro IXLCONN
18–1B
Reason code for the MVS macro IXLCONN
1C–1F
Request parameter header (RPH) address