The General Parameters panels let you specify print parameters
of the TSO/E ALLOCATE command and the JCL OUTPUT and DD statements.
The following panel is the first of four panels.
Figure 1. Printer – General
ParametersICQAPE50 General Parameters Page 1 of 4
Command ===>
Printer Location ..... NY/701/R09
Print Format.......... LETTER
Printer Type.......... 3380
Description........... 3380 printer, letter with logo
Enter or change the following information as required.
To continue press ENTER. To exit without saving, press END.
SYSOUT Class ===> A A-Z, 0-9, or *
SYSOUT Writer ===> ________ SYSOUT writer (if other than JES)
SYSOUT Forms ===> W_______ Forms name for OUTPUT JCL card
OUTDES ===> ________ Output descriptor
Data Control ===> _ ANSI (A) or MACHINE (M)
UCS ===> ____ Character set name to print with
FORMS ===> STD3 SYSOUT forms name if special paper required
FCB ===> STD3 Forms control image or module name
Line Count ===> ___ JES2 maximum number of lines per page
HOLD ===> _ (Y/N)
- SYSOUT CLASS
- Specify the SYSOUT class associated with this printer. Choose
from among the output classes that have been established at your location.
Valid entries are a single character: A-Z, 0-9, or *. Type * (for
JCL OUTPUT and DD statements only) to use the class listed in the
MSGCLASS parameter on the job statement.
- SYSOUT WRITER
- Specify the name of a writer program that modifies system defaults
for printing data sets. Valid names have up to eight characters,
A-Z, 0-9, $, #, or @. The first character cannot be 0-9.
- SYSOUT FORMS
- Specify the name of the forms on which the output data set is
to be printed or punched. Valid names have up to eight characters,
A-Z, 0-9.
- OUTDES
- Use this field to specify the name of an OUTPUT statement that
you want used with the print definition. The name must be specified
in the user's LOGON procedure. Names may have up to 8 characters,
A-Z, 0-9, $, #, or @. The first character cannot be 0-9.
- DATA CONTROL
- Specify the format of a data control character that appears as
the first character of each line of the output data:
- A
- – ANSI format
- M
- – Machine format.
If no data control character is used, leave this
field blank.
- UCS
- Specify the universal character-set (UCS) name for a special character
set to be used on a 3211, 3203 Model 5, or 1403 printer. Valid names
can have up to four characters: A-Z or 0-9. For a list of the UCS
names, see z/OS MVS JCL Reference.
- FORMS
- Type the name of the form on which the output data set is to be
printed or punched. Valid form names have up to four characters,
A-Z, 0-9, $, #, @.
- FCB
- Specify a forms control buffer (FCB) specification that stores
vertical formatting information for printing. The FCB is the four-character
ID of the particular FCB image in SYS1.IMAGELIB. That buffer specifies
the lines per inch and page length to be used. IBM® provides standard FCB images for specific
printers. Valid names can have up to four characters, A-Z, 0-9, $,
#, or @.
- LINE COUNT
- Type the maximum number of lines JES2 is to print on each page.
This number can be from 0 to 255. If you do not specify a number,
JES2 will use the default specified at initialization. You can type
0 to keep JES2 from starting a new page when the number of lines exceeds
the installation default.
- HOLD
- If you want the data set to be placed on a HOLD queue before printing,
type Y. If you do not want the data set to be placed
on a HOLD queue, type N or leave a blank.
Note: If
the pre-defined SYSOUT class has a HOLD/NOHOLD condition associated
with it, that condition overrides what you type here.
The
second panel of the General Parameters is as follows:
Figure 2. Printer – General
ParametersICQAPE51 General Parameters Page 2 of 4
Command ===>
Printer Location ..... NY/701/R09
Print Format ......... LETTER
Printer Type ......... 3380
Description .......... 3380 printer, letter with logo
Enter or change the following information as required.
To continue press ENTER. To exit without saving, press END.
Module Name ===> HDS1 Copy-modification module name
Translate Code ===> _ Table reference character for above
TRC ===> _ (Y/N) Y indicates OPTCD J
Flash Name ===> RPT1 Forms Overlay Name
Flash Count ===> 5_ Number of copies to be flashed
Burst ===> Y (Y/N) Y to burst output
- MODULE NAME
- Specify the name of a module that will be used to modify and print
copies of data sets on the 3800 printer. (Other printers ignore this
parameter.) The name can have up to four characters, A-Z, 0-9, @,
#, or $. The module must be predefined with modification information
and stored in the SYS1.IMAGELIB data set.
- TRANSLATE CODE
- Specify a font to be used with the Modify module. The entries
are related to the font order numbers used on the Printer – Add or
Modify a Font panel. Type 0 for font number 1, 1 for
font number 2, 2 for font number 3, and so on.
- TRC
- This option is for the 3800 printer. Type Y to
indicate that each line of output data begins with a print control
character followed by a table reference character (0, 1, 2, 3, and
so on). The table reference character corresponds to a font to be
used to print that line.
- FLASH NAME
- Type the name of the 3800 forms overlay that this output requires
to be printed over each page of the output data set. The name can
have up to four characters, A-Z, 0-9, @, #, or $.
- FLASH COUNT
- Type the number (from 1 – 255) of copies to be printed with the
overlay, beginning with the first copy printed. This is only for
use with FLASH.
- BURST
-
- Type Y
- To request that 3800 output be burst (separated at the perforation),
trimmed, and stacked. If you do not want the BURST option, type N or
leave a blank. This option is ignored for other printers.
The third panel of the General Parameters is as follows:
Figure 3. Printer – General
ParametersICQAPE52 General Parameters Page 3 of 4
COMMAND ===>
Printer Location .... NY/701/R09
Print Format ......... LETTER
Printer Type ......... 3380
Description .......... 3380 printer, letter with logo
Enter or change the following information as required.
To continue press ENTER. To exit without saving, press END.
Total Copies ===> ___ Total number of copies
Per Group ===> ___ ___ ___ ___ ___ ___ ___
Copy group values (Sum not to exceed 255)
Groupid Name ===> _______ JES2 output group name
Formdef Name ===> ______ 3800-3 formatting member name
Pagedef Name ===> ______ 3800-3 page formatting member name
Index ===> __ 1 to 31 column offset to right
Left Index ===> __ 1 to 31 column offset to left
The fields for the Number of Copies parameter are: - TOTAL COPIES
- Type the number of copies of the data set to be printed. Use
a number from 1 to 255 in a JES2 system and from 1 to 254 in a JES3
system.
- PER GROUP
- Use this option with the 3800 when you want to print each page
a specified number of times before the next page is printed.
Type
the number of times you want each page printed in a complete copy
of the data set. You can enter up to eight group values.
Group
values can be from 1 to 255 with JES2 and from 1 to 254 with JES3.
For 3800 output, this option overrides any entry in the TOTAL COPIES
field.
- GROUPID NAME
- Type the name of an output group to which this output data set
belongs. The name can have up to eight characters, A-Z, or 0-9.
- FORMDEF NAME
- Type the name of a SYS1.IMAGELIB member that contains statements
specifying forms to be used in printing the output data set on a 3800-3
printer. The name can have up to six characters, A-Z, 0-9, @, #,
or $.
The member can specify the following: - Overlay forms to be used in printing
- Location on the page where overlays are to be placed
- Suppressions that can be activated for specified page formats
- PAGEDEF NAME
- Type the name of a SYS1.IMAGELIB member that contains statements
specifying page characteristics for printing the output data set on
a 3800-3 printer. The name can have up to six characters, A-Z, 0-9,
@, #, or $.
The page characteristics include logical page length
and width, line lengths and lines per page, fonts, page types, and
formats.
- INDEX
- The Index parameter sets the left margin for output on a 3211
printer with the Indexing feature. The width of the line is reduced
by the parameter value.
Type a number from 1 to 31. Type 1 to
indicate flush left; type numbers 2 through 31 to
indent the print line between 1 and 30 positions to the right. The
default is 1, flush left.
The INDEX entry is supported only
on JES2 and is only for printing on a 3211 with the Indexing feature.
- LEFT INDEX
- The Left Index parameter sets the right margin for output on a
3211 printer with the Indexing feature. The width of the line is
reduced by the parameter value.
Type a number from 1 to 31. Type 1 to
indicate flush right; type number 2 through 31 to
move the right margin over by 1 to 30 positions. The default is 1;
flush right.
The LEFT INDEX entry is supported only on JES2
and is only for printing on a 3211 with the Indexing feature.
The fourth panel of the General Parameters is as follows:
Figure 4. Printer – ParametersICQAPE60 Parameters Page 4 of 4
Command ===>
Printer Location ..... NY/701/R09
Print Format ......... LETTER
Printer Type ......... 6670
Description .......... 6670 printer, letter with logo
Type or change locally defined parameters, if any.
To exit without saving, press END.
Parameter 1 ===> _____________________________________
Parameter 2 ===> _____________________________________
Parameter 3 ===> _____________________________________
Parameter 4 ===> _____________________________________
Parameter 5 ===> _____________________________________
Parameter 6 ===> _____________________________________
This panel allows you to store information about the print definition
for use by the calling application or print function.
The information at the top of the panel identifies the print definition.
Below it are fields where you can type print parameters specific to
this print definition.
Be sure to type parameters and values in their required format.
|