Parameters
The parameters are explained as follows:
- name
- An optional symbol, starting in column 1, that is the name on
the IWMSCXIT macro invocation. The name must conform to the rules
for an ordinary assembler language symbol.
- ,ACTION=QUIESCE
- ,ACTION=RESUME
- ,ACTION=NULL
- A required parameter, which indicates the type of action requested.
The exit should make an explicit check for the action indicated to
anticipate the introduction of new values in later releases.
- ,ACTION=QUIESCE
- indicates that exit is to cause the server space to perform
an orderly shutdown and terminate. Disconnect should be invoked during
the shutdown phase.
- ,ACTION=RESUME
- indicates that the exit may ignore a previous request to perform
an orderly shutdown and terminate. The server space is now eligible
to be chosen via invocation of IWMSRFSV and may resume normal operation.
- ,ACTION=NULL
- indicates that no exit is to be called. The exit need not check
for this action.
- CONNTKN=conntkn
- A required input parameter, which contains the WLM Connect token
which was returned for the server by Connect (IWMCONN).
To code: Specify the RS-type address, or address
in register (2)-(12), of a 32 bit field.
- ,MF=S
- ,MF=(L,list addr)
- ,MF=(L,list addr,attr)
- ,MF=(L,list addr,0D)
- ,MF=(E,list addr)
- ,MF=(E,list addr,COMPLETE)
- An optional input parameter that specifies the macro form.
Use
MF=S to specify the standard form of the macro, which builds an inline
parameter list and generates the macro invocation to transfer control
to the service. MF=S is the default.
Use MF=L to specify the
list form of the macro. Use the list form together with the execute
form of the macro for applications that require reentrant code. The
list form defines an area of storage that the execute form uses to
store the parameters. Only the PLISTVER parameter may be coded with
the list form of the macro.
Use MF=E to specify the execute
form of the macro. Use the execute form together with the list form
of the macro for applications that require reentrant code. The execute
form of the macro stores the parameters into the storage area defined
by the list form, and generates the macro invocation to transfer control
to the service.
- ,list addr
- The name of a storage area to contain the parameters. For MF=S
and MF=E, this can be an RS-type address or an address in register
(1)-(12).
- ,attr
- An optional 1- to 60-character input string that you use to
force boundary alignment of the parameter list. Use a value of 0F
to force the parameter list to a word boundary, or 0D to force the
parameter list to a doubleword boundary. If you do not code attr,
the system provides a value of 0D.
- ,COMPLETE
- Specifies that the system is to check for required parameters
and supply defaults for omitted optional parameters.
- ,PLISTVER=IMPLIED_VERSION
- ,PLISTVER=MAX
- ,PLISTVER=0
- An optional input parameter that specifies the version of the
macro. PLISTVER determines which parameter list the system generates.
PLISTVER is an optional input parameter on all forms of the macro,
including the list form. When using PLISTVER, specify it on all macro
forms used for a request and with the same value on all of the macro
forms. The values are:
- IMPLIED_VERSION, which is the lowest
version that allows all parameters specified on the request to be
processed. If you omit the PLISTVER parameter, IMPLIED_VERSION
is the default.
- MAX, if you want the parameter list to be
the largest size currently possible. This size might grow from release
to release and affect the amount of storage that your program needs.
If
you can tolerate the size change, IBM recommends that you always specify
PLISTVER=MAX on the list form of the macro. Specifying MAX ensures
that the list-form parameter list is always long enough to hold all
the parameters you might specify on the execute form, when both are
assembled with the same level of the system. In this way, MAX ensures
that the parameter list does not overwrite nearby storage.
- 0, if you use the currently available parameters.
To code: Specify one of the following:
- IMPLIED_VERSION
- MAX
- A decimal value of 0
- ,RETCODE=retcode
- An optional output parameter into which the return code is to
be copied from GPR 15. If you specify 15, GPR15, REG15, or R15 (within
or without parentheses), the value will be left in GPR 15.
To code: Specify the RS-type address of a
fullword field, or register (2)-(12) or (15), (GPR15), (REG15), or
(R15).
- ,RSNCODE=rsncode
- An optional output parameter into which the reason code is to
be copied from GPR 0. If you specify 0, 00, GPR0, GPR00, REG0, REG00,
or R0 (within or without parentheses), the value will be left in GPR
0.
To code: Specify the RS-type address
of a fullword field, or register (0) or (2)-(12), (00), (GPR0), (GPR00),
REG0), (REG00), or (R0).
- ,SRV_MGR_EXIT@=srv_mgr_exit@
- A required input parameter that contains the address of the
Server Manager Connect Exit to be invoked.
To
code: Specify the RS-type address, or address in register
(2)-(12), of a pointer field.
|