Parameters
The parameters are explained as follows:
- name
- An optional symbol, starting in column 1, that is the name on
the IWMRCOLL macro invocation. The name must conform to the rules
for an ordinary assembler language symbol.
- ,ANSAREA=ansarea
- A required output parameter that contains the address
of a storage area to hold the information returned by IWMRCOLL. The
area is mapped by the IWMWRCAA mapping macro.
To
code: Specify the RS-type address, or address in register (2)-(12)
of a character field.
- ,ANSLEN=anslen
- A required input parameter that contains the length
of the storage area (answer area) you are providing on ANSAREA.
To code: Specify the RS-type address, or address
in register (2)-(12) of a fullword field.
- ,ANSTOKN=anstoken,
- A required input/output parameter that contains a token value.
On your first call to IWMRCOLL, you specify ANSTOKEN as an output
parameter. IWMRCOLL provides a token value that is required for subsequent
calls to IWMRCOLL.
To code: Specify the RS-type
address, or address in register (2)-(12) of an 8-character field.
- ICS=NO
- ICS=YES
- An optional parameter that specifies whether IWMRCOLL should
return ICS information, or workload activity information. The default
is ICS=NO.
- ICS=NO
- Specifies that IWMRCOLL should return workload activity information.
- ICS=YES
- Specifies that IWMRCOLL should return ICS information. It is
valid for systems prior to z/OS® R3
only.
- ,ICSAREA=icsarea
- When ICS=YES is specified, a required output parameter that
is valid for systems prior to z/OS R3
only.
To code: Specify the RS-type address,
or address in register (2)-(12) of a character field.
- ,ICSLEN=icslen
- When ICS=YES is specified, a required input parameter that is
valid for systems prior to z/OS R3
only.
To code: Specify the RS-type address,
or address in register (2)-( 12) of a fullword field.
- ,ICSQLEN=icsqlen
- When ICS=YES is specified, a required output parameter that
is valid for systems prior to z/OS R3
only.
To code: Specify the RS-type address,
or address in register (2)-(12) of a fullword field.
- ,MAXLEN=maxlen
- A required output parameter that contains the maximum length
of the storage area required by IWMRCOLL to contain all the performance
data for transactions that might run while the ANSTOKN is valid.
To code: Specify the RS-type address, or address
in register (2)-(12) of a fullword field.
- ,MF=S
- ,MF=(L,list
addr)
- ,MF=(L,list addr, attr)
- ,MF=(L,list addr0D
- ,MF=(E,list addr)
- ,MF=(E,list addr,COMPLETE)
- An optional input parameter that specifies the macro form.
Use
MF=S to specify the standard form of the macro, which builds an inline
parameter list and generates the macro invocation to transfer control
to the service. MF=S is the default.
Use MF=L to specify the
list form of the macro. Use the list form together with the execute
form of the macro for applications that require reentrant code. The
list form defines an area of storage that the execute form uses to
store the parameters. Only the PLISTVER parameter may be coded with
the list form of the macro.
Use MF=E to specify the execute
form of the macro. Use the execute form together with the list form
of the macro for applications that require reentrant code. The execute
form of the macro stores the parameters into the storage area defined
by the list form, and generates the macro invocation to transfer control
to the service.
- ,list addr
- The name of a storage area to contain the parameters. For MF=S
and MF=E, this can be an RS-type address or an address in register
(1)-(12).
- ,attr
- An optional 1 to 60 character input string that you use to force
boundary alignment of the parameter list. Use a value of X'0F' to
force the parameter list to a word boundary, or X'0D' to
force the parameter list to a doubleword boundary. If you do not code ,attr, the system provides a value of X'0D'.
- ,COMPLETE
- Specifies that the system is to check for required
parameters and supply defaults for omitted optional parameters.
- ,MINLEN=minlen
- A required output parameter that contains the minimum
length of the storage area required by IWMRCOLL to contain all existing
performance data.
To code: Specify the RS-type
address, or address in register (2)-( 12) of a fullword field.
- ,PLISTVER=IMPLIED_VERSION
- ,PLISTVER=MAX
- ,PLISTVER=0
- An optional input parameter that specifies the version of the
macro. PLISTVER determines which parameter list the system generates.
PLISTVER is an optional input parameter on all forms of the macro,
including the list form. When using PLISTVER, specify it on all macro
forms used for a request and with the same value on all of the macro
forms. The values are:
- IMPLIED_VERSION
- Is the lowest version that allows all parameters specified on
the request to be processed. If you omit the PLISTVER parameter, IMPLIED_VERSION
is the default.
- MAX
- Specify PLISTVER=MAX if you want the parameter list to be the
largest size currently possible. This size might grow from release
to release and affect the amount of storage that your program needs.
If
you can tolerate the size change, IBM® recommends
that you always specify PLISTVER=MAX on the list form of the macro.
Specifying MAX ensures that the list-form parameter list is always
long enough to hold all the parameters you might specify on the execute
form, when both are assembled with the same level of the system. In
this way, MAX ensures that the parameter list does not overwrite nearby
storage.
- 0
- Specify PLISTVER=0 to use the currently available parameters.
To code: Specify one of the following:
- IMPLIED_VERSION
- MAX
- A decimal value of 0
- ,RETCODE=retcode
- An optional output parameter into which the return code is to
be copied from GPR 15. If you specify 15, GPR15, REG15,
or R15 (with or without parentheses), the value will be left in GPR
15.
To code: Specify the RS-type address
of a fullword field, or register (2)-(12), or (15),
(GPR15), (REG15), or (R15).
- ,RSNCODE=rsncode
- An optional output parameter into which the reason code is to
be copied from GPR 0. If you specify 0, 00, GPR0,
GPR00, REG0, REG00, or R0 (with or without parentheses), the value
will be left in GPR 0.
To code: Specify
the RS-type address of a fullword field, or register (0)
or (2)-(12), (00), (GPR0), (GPR00), REG0), (REG00), or (R0).
|