Parameters
The parameters are explained as follows:
- name
- An optional symbol, starting in column 1, that is the name on
the IWMMXDC macro invocation. The name must conform to the rules for
an ordinary assembler language symbol.
- ,MF=S
- ,MF=(L,list addr)
- ,MF=(L,list
addr,attr)
- ,MF=(L,list addr,0D)
- ,MF=(E,list addr)
- ,MF=(E,list addr,COMPLETE)
- An optional input parameter that specifies the macro form.
Use
MF=S to specify the standard form of the macro, which builds an inline
parameter list and generates the macro invocation to transfer control
to the service. MF=S is the default.
Use MF=L to specify the
list form of the macro. Use the list form together with the execute
form of the macro for applications that require reentrant code. The
list form defines an area of storage that the execute form uses to
store the parameters. Only the PLISTVER parameter may be coded with
the list form of the macro.
Use MF=E to specify the execute
form of the macro. Use the execute form together with the list form
of the macro for applications that require reentrant code. The execute
form of the macro stores the parameters into the storage area defined
by the list form, and generates the macro invocation to transfer control
to the service.
- ,list addr
- The name of a storage area to contain the parameters. For MF=S
and MF=E, this can be an RS-type address or an address in register
(1)-(12).
- ,attr
- An optional 1- to 60-character input string that you use to
force boundary alignment of the parameter list. Use a value of 0F
to force the parameter list to a word boundary, or 0D to force the
parameter list to a doubleword boundary. If you do not code attr, the system provides a value of 0D.
- ,COMPLETE
- Specifies that the system is to check for required parameters
and supply defaults for omitted optional parameters.
- ,OWNER_TKN=owner_tkn
- When RESOURCE_TYPE=BUFFER_POOL is specified, a required input
parameter, which contains data associated with the resource that was
passed to registration (IWM4MREG).
To code: Specify
the RS-type address, or address in register (2)-(12), of an 8-character
field.
- ,PLISTVER=IMPLIED_VERSION
- ,PLISTVER=MAX
- ,PLISTVER=0
- An optional input parameter that specifies the version of the
macro. PLISTVER determines which parameter list the system generates.
PLISTVER is an optional input parameter on all forms of the macro,
including the list form. When using PLISTVER, specify it on all macro
forms used for a request and with the same value on all of the macro
forms. The values are:
- IMPLIED_VERSION, which is the lowest
version that allows all parameters specified on the request to be
processed. If you omit the PLISTVER parameter, IMPLIED_VERSION
is the default.
- MAX, if you want the parameter list to be
the largest size currently possible. This size might grow from release
to release and affect the amount of storage that your program needs.
If
you can tolerate the size change, IBM® recommends
that you always specify PLISTVER=MAX on the list form of the macro.
Specifying MAX ensures that the list-form parameter list is always
long enough to hold all the parameters you might specify on the execute
form, when both are assembled with the same level of the system. In
this way, MAX ensures that the parameter list does not overwrite nearby
storage.
- 0, if you use the currently available
parameters.
To code: Specify one of the following:
- IMPLIED_VERSION
- MAX
- A decimal value of 0
- ,RES_#HITS=res_#hits
- When RESOURCE_TYPE=BUFFER_POOL is specified, an optional output
parameter, which contains the number of hits among the references
to the bufferpool since the last invocation of the data collection
exit. The corresponding field in the parameter list (IWMMXDC MF=(L))
must be set by the exit.
To code: Specify
the RS-type address, or address in register (2)-(12), of a fullword
field.
- ,RES_#REFERENCES=res_#references
- When RESOURCE_TYPE=BUFFER_POOL is specified, an optional output
parameter, which contains the number of references to the bufferpool
since the last invocation of the data collection exit. The corresponding
field in the parameter list (IWMMXDC MF=(L)) must be set by the exit.
To code: Specify the RS-type address, or address
in register (2)-(12), of a fullword field.
- ,RES_CUR_SIZE=res_cur_size
- When RESOURCE_TYPE=BUFFER_POOL is specified, an optional output
parameter, which contains the current size (in 4K pages) associated
with the specified resource. The corresponding field in the parameter
list (IWMMXDC MF=(L)) must be set by the exit.
To
code: Specify the RS-type address, or address in register
(2)-(12), of a fullword field.
- ,RES_DATA_EXIT@=res_data_exit@
- A required input parameter that contains the address of the
resource data collection exit to be invoked.
To
code: Specify the RS-type address, or address in register
(2)-(12), of a pointer field.
- ,RES_INUSE_SIZE=res_inuse_size
- When RESOURCE_TYPE=BUFFER_POOL is specified, an optional output
parameter, which contains the current in use size (in 4K pages) associated
with the specified resource. The corresponding field in the parameter
list (IWMMXDC MF=(L)) must be set by the exit.
To
code: Specify the RS-type address, or address in register
(2)-(12), of a fullword field.
- RESOURCE_TKN=resource_tkn
- A required input parameter, which contains the associated WLM
resource token which is returned by the registration (IWM4MREG).
To code: Specify the RS-type address, or address
in register (2)-(12), of an 8-character field.
- ,RESOURCE_TYPE=BUFFER_POOL
- ,RESOURCE_TYPE=NULL
- A required parameter, which indicates the type of resource being
registered.
- ,RESOURCE_TYPE=BUFFER_POOL
- indicates that a bufferpool is being collected.
- ,RESOURCE_TYPE=NULL
- indicates that no exit is to be called.
- ,RETCODE=retcode
- An optional output parameter into which the return code is to
be copied from GPR 15.
To code: Specify
the RS-type address of a fullword field, or register (2)-(12).
- ,RSNCODE=rsncode
- An optional output parameter into which the reason code is to
be copied from GPR 0.
To code: Specify
the RS-type address of a fullword field, or register (2)-(12).
|