z/OS MVS Programming: Workload Management Services
Previous topic | Next topic | Contents | Index | Contact z/OS | Library | PDF


Parameters

z/OS MVS Programming: Workload Management Services
SC34-2663-00

Parameters

The parameters are explained as follows:

name
An optional symbol, starting in column 1, that is the name on the IWMMNTFY macro invocation. The name must conform to the rules for an ordinary assembler language symbol.
,COMPLETION=YES
,COMPLETION=NO
A required parameter, which indicates whether the (or possibly one of several) major execution phase(s) is(are) now complete.
,COMPLETION=YES
indicates that execution for an entire phase of processing has now completed. Typically IWMMNTFY Completion(Yes) would be issued as a result of the completion of the transaction program for the work request. When a work request is comprised of several (typically cascaded) transaction programs, each would correspond to an invocation of IWMMNTFY Completion(Yes).

The execution time, as given by the difference between the IWMMNTFY ENDTIME value and the Execution start time (established via IWM4MINI), will be added to the running total execution time for the service class. There may still be "output" processing left to perform for the work request, which time would be accounted for via IWMRPT. There may also be operations corresponding to hardening of the database data outside the scope of NOTIFY.

,COMPLETION=NO
indicates that this invocation of Notify does not correspond to the completion of an entire execution segment. Instead this invocation of Notify corresponds to the portion of the work request represented by the monitoring environment. For example, use Completion(No) when this portion of processing behaves like a subroutine in the execution phase, which is therefore a subset of the execution time passed in another NOTIFY.

The execution time, as given by the difference between the IWMMNTFY ENDTIME value and the Execution start time (established via IWM4MINI), will be treated separately from that passed for Completion(Yes), since otherwise there would be double-counting.

,CONNTKN=conntkn
,CONNTKN=NO_CONNTKN
An optional input parameter, which is returned by IWM4CON. The default is NO_CONNTKN, which indicates that no connect token is passed.

To code: Specify the RS-type address, or address in register (2)-(12), of a 32 bit field.

,DISASSOCIATE=YES
,DISASSOCIATE=NO
A required parameter, which indicates whether the work request should be disassociated from the monitoring environment or not.
,DISASSOCIATE=YES
indicates that the work request should be disassociated from the monitoring environment.
,DISASSOCIATE=NO
indicates that the work request should not be disassociated from the monitoring environment.
,ENDTIME=endtime
,ENDTIME=CURRENT
An optional input parameter, which specifies the ending execution time for the transaction in STCK format. The default is CURRENT, which indicates that the current time should be used.

To code: Specify the RS-type address, or address in register (2)-(12), of a 64 bit field.

,MF=S
,MF=(L,list addr)
,MF=(L,list addr,attr)
,MF=(L,list addr,0D)
,MF=(E,list addr)
,MF=(E,list addr,COMPLETE)
An optional input parameter that specifies the macro form.

Use MF=S to specify the standard form of the macro, which builds an inline parameter list and generates the macro invocation to transfer control to the service. MF=S is the default.

Use MF=L to specify the list form of the macro. Use the list form together with the execute form of the macro for applications that require reentrant code. The list form defines an area of storage that the execute form uses to store the parameters. Only the PLISTVER parameter may be coded with the list form of the macro.

Use MF=E to specify the execute form of the macro. Use the execute form together with the list form of the macro for applications that require reentrant code. The execute form of the macro stores the parameters into the storage area defined by the list form, and generates the macro invocation to transfer control to the service.

,list addr
The name of a storage area to contain the parameters. For MF=S and MF=E, this can be an RS-type address or an address in register (1)-(12).
,attr
An optional 1- to 60-character input string that you use to force boundary alignment of the parameter list. Use a value of 0F to force the parameter list to a word boundary, or 0D to force the parameter list to a doubleword boundary. If you do not code attr, the system provides a value of 0D.
,COMPLETE
Specifies that the system is to check for required parameters and supply defaults for omitted optional parameters.
,MONTKN=montkn
A required input parameter, which contains the delay monitoring token

To code: Specify the RS-type address, or address in register (2)-(12), of a 32 bit field.

,PLISTVER=IMPLIED_VERSION
,PLISTVER=MAX
,PLISTVER=0
,PLISTVER=1
An optional input parameter that specifies the version of the macro. PLISTVER determines which parameter list the system generates. PLISTVER is an optional input parameter on all forms of the macro, including the list form. When using PLISTVER, specify it on all macro forms used for a request and with the same value on all of the macro forms. The values are:
  • IMPLIED_VERSION, which is the lowest version that allows all parameters specified on the request to be processed. If you omit the PLISTVER parameter, IMPLIED_VERSION is the default.
  • MAX, if you want the parameter list to be the largest size currently possible. This size might grow from release to release and affect the amount of storage that your program needs.

    If you can tolerate the size change, IBM® recommends that you always specify PLISTVER=MAX on the list form of the macro. Specifying MAX ensures that the list-form parameter list is always long enough to hold all the parameters you might specify on the execute form; in this way, MAX ensures that the parameter list does not overwrite nearby storage.

  • 0, which supports all parameters except those specifically referenced in higher versions.
  • 1, which supports the following parameter and those from version 0:
    WORKREQ_STA

To code: Specify one of the following:

  • IMPLIED_VERSION
  • MAX
  • A decimal value of 0, or 1
,RETCODE=retcode
An optional output parameter into which the return code is to be copied from GPR 15.

To code: Specify the RS-type address of a fullword field, or register (2)-(12).

,RSNCODE=rsncode
An optional output parameter into which the reason code is to be copied from GPR 0.

To code: Specify the RS-type address of a fullword field, or register (2)-(12).

,SYSEVPL=sysevpl
When TRAXFRPT=YES is specified, a required input parameter, which is the fully initialized SYSEVENT parameter list, as mapped by IHATRBPL.

To code: Specify the RS-type address, or address in register (2)-(12), of a 40-character field.

TRAXFRPT=NO
TRAXFRPT=YES
An optional parameter, which indicated prior to z/OS® R3 whether a SYSEVENT TRAXFRPT should be issued when the system was in compatibility mode. This has become irrevelant. However, for compatibility reasons TRAXFRPT can still be set but has no effect. The default is TRAXFRPT=NO.
TRAXFRPT=NO
indicates that no SYSEVENT TRAXFRPT should be issued.
TRAXFRPT=YES
indicated prior to z/OS R3 that a SYSEVENT TRAXFRPT should be issued when the system was in compatibility mode. This has become irrevelant. However, for compatibility reasons TRAXFRPT can still be set but has no effect.
,WORKREQ_STA=workreq_sta
,WORKREQ_STA=IWMEWLMARMSTATUSNONE
When DISASSOCIATE=YES is specified, an optional input parameter, which contains the completion status code of the work request. Available completion status codes (defined in macro IWMYCON) are the following:
  • IwmEwlmArmStatusGood(0)
  • IwmEwlmArmStatusAborted(1)
  • IwmEwlmArmStatusFailed(2)
  • IwmEwlmArmStatusUnknown(3)
These codes correspond to status codes in the OpenGroup ARM 4.0 Standard. For further information about the meaning of the status codes, refer to the ARM 4.0 Standard at http://www.opengroup.org/management/arm. The default is IWMEWLMARMSTATUSNONE. This indicates that the COMPLETION parameter value and internal information in the monitoring environment are examined to determine the status of the work request. If COMPLETION=YES is specified and no abnormal event was recorded for the monitoring environment with the IWMMABNL service, the completion status IwmEwlmArmStatusGood is reported to EWLM. If an abnormal event was reported via IWMMABNL or COMPLETION=NO was specified, the completion status IwmEwlmArmStatusFailed is reported to EWLM.

To code: Specify the RS-type address, or address in register (2)-(12), of a fullword field.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014