Parameters
The parameters are explained as follows:
- name
- An optional symbol, starting in column 1, that is the name on
the IWMMNTFY macro invocation. The name must conform to the rules
for an ordinary assembler language symbol.
- ,COMPLETION=YES
- ,COMPLETION=NO
- A required parameter, which indicates whether the (or possibly
one of several) major execution phase(s) is(are) now complete.
- ,COMPLETION=YES
- indicates that execution for an entire phase of processing has
now completed. Typically IWMMNTFY Completion(Yes) would be issued
as a result of the completion of the transaction program for the work
request. When a work request is comprised of several (typically cascaded)
transaction programs, each would correspond to an invocation of IWMMNTFY
Completion(Yes).
The execution time, as given by the difference
between the IWMMNTFY ENDTIME value and the Execution start time (established
via IWM4MINI), will be added to the running total execution time for
the service class. There may still be "output" processing left to
perform for the work request, which time would be accounted for via
IWMRPT. There may also be operations corresponding to hardening of
the database data outside the scope of NOTIFY.
- ,COMPLETION=NO
- indicates that this invocation of Notify does not correspond
to the completion of an entire execution segment. Instead this invocation
of Notify corresponds to the portion of the work request represented
by the monitoring environment. For example, use Completion(No) when
this portion of processing behaves like a subroutine in the execution
phase, which is therefore a subset of the execution time passed in
another NOTIFY.
The execution time, as given by the difference
between the IWMMNTFY ENDTIME value and the Execution start time (established
via IWM4MINI), will be treated separately from that passed for Completion(Yes),
since otherwise there would be double-counting.
- ,CONNTKN=conntkn
- ,CONNTKN=NO_CONNTKN
- An optional input parameter, which is returned by IWM4CON.
The default is NO_CONNTKN, which indicates that no connect token is
passed.
To code: Specify the RS-type address,
or address in register (2)-(12), of a 32 bit field.
- ,DISASSOCIATE=YES
- ,DISASSOCIATE=NO
- A required parameter, which indicates whether the work request
should be disassociated from the monitoring environment or not.
- ,DISASSOCIATE=YES
- indicates that the work request should be disassociated from
the monitoring environment.
- ,DISASSOCIATE=NO
- indicates that the work request should not be disassociated
from the monitoring environment.
- ,ENDTIME=endtime
- ,ENDTIME=CURRENT
- An optional input parameter, which specifies the ending execution
time for the transaction in STCK format. The default is CURRENT, which
indicates that the current time should be used.
To
code: Specify the RS-type address, or address in register (2)-(12),
of a 64 bit field.
- ,MF=S
- ,MF=(L,list addr)
- ,MF=(L,list
addr,attr)
- ,MF=(L,list addr,0D)
- ,MF=(E,list addr)
- ,MF=(E,list addr,COMPLETE)
- An optional input parameter that specifies the macro form.
Use
MF=S to specify the standard form of the macro, which builds an inline
parameter list and generates the macro invocation to transfer control
to the service. MF=S is the default.
Use MF=L to specify the
list form of the macro. Use the list form together with the execute
form of the macro for applications that require reentrant code. The
list form defines an area of storage that the execute form uses to
store the parameters. Only the PLISTVER parameter may be coded with
the list form of the macro.
Use MF=E to specify the execute
form of the macro. Use the execute form together with the list form
of the macro for applications that require reentrant code. The execute
form of the macro stores the parameters into the storage area defined
by the list form, and generates the macro invocation to transfer control
to the service.
- ,list addr
- The name of a storage area to contain the parameters. For MF=S
and MF=E, this can be an RS-type address or an address in register
(1)-(12).
- ,attr
- An optional 1- to 60-character input string that you use to
force boundary alignment of the parameter list. Use a value of 0F
to force the parameter list to a word boundary, or 0D to force the
parameter list to a doubleword boundary. If you do not code attr, the system provides a value of 0D.
- ,COMPLETE
- Specifies that the system is to check for required parameters
and supply defaults for omitted optional parameters.
- ,MONTKN=montkn
- A required input parameter, which contains the delay monitoring
token
To code: Specify the RS-type address,
or address in register (2)-(12), of a 32 bit field.
- ,PLISTVER=IMPLIED_VERSION
- ,PLISTVER=MAX
- ,PLISTVER=0
- ,PLISTVER=1
- An optional input parameter that specifies the version of the
macro. PLISTVER determines which parameter list the system generates.
PLISTVER is an optional input parameter on all forms of the macro,
including the list form. When using PLISTVER, specify it on all macro
forms used for a request and with the same value on all of the macro
forms. The values are:
- IMPLIED_VERSION, which is the lowest
version that allows all parameters specified on the request to be
processed. If you omit the PLISTVER parameter, IMPLIED_VERSION
is the default.
- MAX, if you want the parameter list to be
the largest size currently possible. This size might grow from release
to release and affect the amount of storage that your program needs.
If
you can tolerate the size change, IBM® recommends
that you always specify PLISTVER=MAX on the list form of the macro.
Specifying MAX ensures that the list-form parameter list is always
long enough to hold all the parameters you might specify on the execute
form; in this way, MAX ensures that the parameter list does not overwrite
nearby storage.
- 0, which supports all parameters
except those specifically referenced in higher versions.
- 1, which supports the following
parameter and those from version 0:
WORKREQ_STA
To code: Specify one of the following:
- IMPLIED_VERSION
- MAX
- A decimal value of 0, or 1
- ,RETCODE=retcode
- An optional output parameter into which the return code is to
be copied from GPR 15.
To code: Specify the
RS-type address of a fullword field, or register (2)-(12).
- ,RSNCODE=rsncode
- An optional output parameter into which the reason code is to
be copied from GPR 0.
To code: Specify the
RS-type address of a fullword field, or register (2)-(12).
- ,SYSEVPL=sysevpl
- When TRAXFRPT=YES is specified, a required input parameter,
which is the fully initialized SYSEVENT parameter list, as mapped
by IHATRBPL.
To code: Specify the RS-type
address, or address in register (2)-(12), of a 40-character field.
- TRAXFRPT=NO
- TRAXFRPT=YES
- An optional parameter, which indicated prior to z/OS® R3 whether a SYSEVENT TRAXFRPT
should be issued when the system was in compatibility mode. This
has become irrevelant. However, for compatibility reasons TRAXFRPT
can still be set but has no effect. The default is TRAXFRPT=NO.
- TRAXFRPT=NO
- indicates that no SYSEVENT TRAXFRPT should be issued.
- TRAXFRPT=YES
- indicated prior to z/OS R3
that a SYSEVENT TRAXFRPT should be issued when the system was in compatibility
mode. This has become irrevelant. However, for compatibility reasons
TRAXFRPT can still be set but has no effect.
- ,WORKREQ_STA=workreq_sta
- ,WORKREQ_STA=IWMEWLMARMSTATUSNONE
- When DISASSOCIATE=YES is specified, an optional input parameter,
which contains the completion status code of the work request. Available
completion status codes (defined in macro IWMYCON) are the following:
- IwmEwlmArmStatusGood(0)
- IwmEwlmArmStatusAborted(1)
- IwmEwlmArmStatusFailed(2)
- IwmEwlmArmStatusUnknown(3)
These codes correspond to status codes in the OpenGroup ARM 4.0
Standard. For further information about the meaning of the status
codes, refer to the ARM 4.0 Standard at http://www.opengroup.org/management/arm.
The default is IWMEWLMARMSTATUSNONE. This indicates that the COMPLETION
parameter value and internal information in the monitoring environment
are examined to determine the status of the work request. If COMPLETION=YES
is specified and no abnormal event was recorded for the monitoring
environment with the IWMMABNL service, the completion status IwmEwlmArmStatusGood
is reported to EWLM. If an abnormal event was reported via IWMMABNL
or COMPLETION=NO was specified, the completion status IwmEwlmArmStatusFailed
is reported to EWLM.
To code: Specify
the RS-type address, or address in register (2)-(12), of a fullword
field.
|