TIME macro - is type 3, gets no lock.
Calls module IEAVRT01, entry point IGC0001A.
Bits | Register 0 Contents | |
---|---|---|
.... | 0000 | 32-bit unsigned binary number representing the number of elapsed timer units. (A timer unit is approximately 26.04 microseconds.) |
.... | 0001 | Elapsed time in hundredths of a second. |
.... | 0010 | Packed decimal digits representing elapsed time in hours, minutes, seconds, tenths of a second, and hundredths of a second (HHMMSShh). |
.... | 0011 | Elapsed time where bit 51 of doubleword is equivalent to one microsecond. |
.... | 0100 | The current TOD clock value is to be returned. |
.1.. | .... | The routine specified by the ERRET operand gets control on an environmental error. |
1... | .... | GMT values are to be returned. |