z/OS MVS Programming: Sysplex Services Reference
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Return and Reason Codes

z/OS MVS Programming: Sysplex Services Reference
SA38-0658-00

When the system returns control to your program:
  • GPR 15 (and RETCODE, if specified) contains a return code.
  • If the return code is not zero, GPR 0 (and RSNCODE, if specified) contains a reason code.
Note: The return and reason codes will also be put into the answer area (mapped by IXLYLAA), if there is one, when the request completes.
The IXLYCON macro provides equate symbols for the return and reason codes. The equate symbols associated with each hexadecimal return code are as follows:
0
IXLRETCODEOK
4
IXLRETCODEWARNING
8
IXLRETCODEPARMERROR
C
IXLRETCODEENVERROR
10
IXLRETCODECOMPERROR

The following table contains hexadecimal return and reason codes, the equate symbols associated with each reason code, and the meaning and suggested action for each return and reason code.

Table 1. Return and Reason Codes for IXLLIST REQUEST=DEQ_EVENTQ Macro
Hexadecimal Return Code Hexadecimal Reason Code

Equate Symbol
Meaning and Action

0 None. Meaning: If you specified a MODE value of ASYNCECB, ASYNCEXIT, ASYNCTOKEN, or ASYNCNORESPONSE, the request has been successfully initiated. The answer area (ANSAREA) fields will not contain valid information until the asynchronous processing has completed. For any other MODE value, the request has successfully completed.
Action:
  • If you specified MODE=ASYNCECB, wait on the ECB you specified in REQECB.
  • If you specified MODE=ASYNCEXIT, the connection's complete exit will be given control when the request has completed.
  • If you specified MODE=ASYNCTOKEN, use REQTOKEN when calling IXLFCOMP to determine when the request has completed.
4 xxxx0402 Equate Symbol: IXLRSNCODEASYNCH
Meaning: The request could not be processed synchronously. It will be processed asynchronously. The answer area (ANSAREA) fields will not contain valid information until the asynchronous processing has completed.
  • If MODE=SYNCECB was specified, the ECB specified for REQECB will be posted when the request has finished.
  • If MODE=SYNCEXIT was specified, the connection's complete exit will be given control when the request has finished.
  • If MODE=SYNCTOKEN was specified, an asynchronous request token was returned in the area specified by REQTOKEN. This request token may be specified on the IXLFCOMP macro to determine when the request has finished.
Action:
  • If you specified MODE=SYNCECB, wait on the ECB you specified in REQECB.
  • If you specified MODE=SYNCEXIT, the connection's complete exit will be given control when the request has completed.
  • If you specified MODE=SYNCTOKEN, use REQTOKEN when calling IXLFCOMP to determine when the request has completed.
4 xxxx0409 Equate Symbol: IXLRSNCODETIMEOUT
Meaning: The request completed prematurely because it exceeded the coupling facility model-dependent time-out criteria. The following information has been returned in the answer area:
  • The number of event monitor controls that were read and dequeued from the event queue (field LAADEQ_NUMEMCREAD).
  • The number of event monitor controls that remain on the event queue (field LAADEQ_EMCQUEUEDCNT).

Action:Rreissue the request to continue.

Be sure to process the information returned from this request before reissuing the request. The data returned from this request will be overwritten if you specify the same buffer address. Continue to reissue the request until the return code indicates that all processing has completed.

For more information about premature completion of a DEQ_EVENTQ request, see z/OS MVS Programming: Sysplex Services Guide.

8 xxxx0801 Equate Symbol: IXLRSNCODEBADPARMLIST

Meaning: Program error. The parameter list for this request is not addressable. The answer area (ANSAREA) fields are not valid.

Action: Verify that:
  • The parameter list address is uncorrupted.
  • The parameter list is addressable in the caller's primary address space.
  • If you are issuing this macro while disabled, the parameter list resides in either page-fixed or DREF storage.
  • If you are issuing this macro in AR-mode and you specified the parameter list address using explicit register notation, the corresponding access register was updated appropriately.
  • If you are issuing this macro in AR-mode, SYSSTATE ASCENV=AR must be issued before issuing this macro.
8 xxxx0804 Equate Symbol: IXLRSNCODEBADVERSIONNUM (or IXLRSNCODEBADVERSION#)

Meaning: The version number in the macro parameter list is not compatible with the level of XES currently being used. The answer area (ANSAREA) fields are not valid.

Action:
  • Verify that your program did not overlay the parameter list storage.
  • Verify that your program was assembled with the correct macro library for the release of MVS™ on which your program is running.
8 xxxx080A Equate Symbol: IXLRSNCODEBADCONTOKEN

Meaning: Program error. The specified connect token (CONTOKEN) was not valid for one of the following reasons:

  1. The user with the connection identifier represented by the token has disconnected from the structure.
  2. The connector's task (the task that issued IXLCONN) ended.
  3. The specified token is not the token that was returned from IXLCONN.
  4. The request was issued from an address space other than the address space in which IXLCONN was issued.
  5. The connect token was invalidated during rebuild.
  6. The connect token was invalidated by XES.
Note: The answer area (ANSAREA) fields are not valid.

Action: Take the action with the corresponding meaning.

  1. Discontinue use of the structure. Perform recovery and cleanup for the structure and check the protocol for the use of the structure to determine why you did not know of the disconnection.
  2. Discontinue use of the structure. Perform recovery and cleanup for the structure and check the protocol for the use of the structure to determine why you did not know that the task ended.
  3. The contoken is returned in the CONACONTOKEN field of the answer area specified on the IXLCONN request.
  4. Issue your request from the same address space the IXLCONN was issued in.
  5. Wait for the rebuild to complete, and try again.
  6. Discontinue use of the structure. Perform recovery and cleanup for the structure.
8 xxxx0824 Equate Symbol: IXLRSNCODEWRONGSTRTYPE

Meaning: Program error. The connection specified by CONTOKEN is not to a list structure.

Action: Specify the appropriate CONTOKEN value, and rerun your program. The CONTOKEN is returned in the answer area provided on the IXLCONN invocation. The type of structure built is passed on the TYPE parameter of the IXLCONN macro.

8 xxxx0833 Equate Symbol: IXLRSNCODEBADPGBLATTR

Meaning: Program error. The storage area specified by BUFFER, or one of the buffers in the BUFLIST list is specified as being pageable (PAGEABLE=YES), but is not.

Action: Change the buffer area(s) to pageable storage, or specify PAGEABLE=NO. See the PAGEABLE parameter description for specification instructions.

8 xxxx0834 Equate Symbol: IXLRSNCODEBADNONPGBLATTR

Meaning: Program error. The storage area specified by BUFFER, or one of the buffers in the BUFLIST list, is specified as being nonpageable (PAGEABLE=NO), but is either pageable or not addressable.

Action: Ensure that:
  • The type of storage in the buffer area corresponds to the value you specified on the PAGEABLE parameter. See the PAGEABLE parameter description for specification instructions.
  • The correct buffer address was used.
  • The buffer area was not previously freed.
  • If you are calling IXLLIST while disabled, the buffers must reside in either page-fixed or DREF storage.
  • The buffer areas were allocated in a storage key that matches the key specified by the BUFSTGKEY parameter, or, if BUFSTGKEY is omitted, the caller's PSW key.
  • If BUFLIST was specified and your program is running in AR-mode:
    • If the BUFFER or BUFLIST parameter was specified using explicit register notation, the corresponding access register was updated appropriately.
    • The BUFALET specification is correct.
    • You specified SYSSTATE ASCENV=AR before issuing the IXLLIST macro.
8 xxxx0835 Equate Symbol: IXLRSNCODEBADDATAADDR

Meaning: Program error. The storage area specified by BUFFER, or one of the buffers in the BUFLIST list, is not addressable.

Action: Ensure that:
  • The correct buffer address was used.
  • The buffer area was not previously freed.
  • The buffer area was allocated in a storage key that matches the key specified using the BUFSTGKEY parameter, or, if BUFSTGKEY is omitted, the caller's PSW key.
  • If BUFLIST was specified and your program is running in AR mode:
    • The BUFALET specification is correct.
    • You specified SYSSTATE ASCENV=AR before issuing the macro.
8 xxxx0836 Equate Symbol: IXLRSNCODEBADREALADDR

Meaning: Program error. Real storage addresses were provided in the BUFLIST list, but one of the buffers is not addressable in central storage.

Action:
  • Verify that BUFADDRTYPE was specified as you intended.
  • Ensure that the buffer addresses specified by BUFLIST are valid.
8 xxxx0838 Equate Symbol: IXLRSNCODEBADANSAREA

Meaning: Program error. The storage area specified by ANSAREA is not addressable.

Action: Ensure that:
  • The answer area address specified by ANSAREA is valid.
  • If the caller is running in AR-mode and the ANSAREA parameter was specified using explicit register notation, the corresponding access register was updated appropriately.
  • The address specified for ANSAREA is addressable in the caller's primary address space or from the caller's PASN access list.
  • If you are calling IXLLIST while disabled, ANSAREA must reside in either page-fixed or DREF storage.
  • If you are calling IXLLIST in AR-mode, SYSSTATE ASCENV=AR must be issued before the IXLLIST macro.
8 xxxx0839 Equate Symbol: IXLRSNCODEBADREQTOKENAREA

Meaning: Program error. The storage area specified by REQTOKEN is not addressable.

Action: Ensure that:
  • The request token area specified by REQTOKEN is valid.
  • If the caller is running in AR-mode and the REQTOKEN parameter was specified using explicit register notation, the corresponding access register was updated appropriately.
  • If you are calling IXLLIST while disabled, REQTOKEN must reside in either page-fixed or DREF storage.
  • If you are calling IXLLIST in AR-mode, SYSSTATE ASCENV=AR must be issued before the IXLLIST macro.
8 xxxx083D Equate Symbol: IXLRSNCODEBADANSLEN

Meaning: Program error. The length of the answer area, as specified by ANSLEN, is not sufficient to contain answer area information. The answer area (ANSAREA) fields do not contain valid information.

Action: Increase the size of the answer area, and rerun your program. The minimum size of the ANSAREA is in the LAA_LEN field of the IXLYLAA mapping macro.

8 xxxx084A Equate Symbol: IXLRSNCODENOKEYS

Meaning: Program error. The structure does not support the use of entry keys. The IXLLIST request type either required the structure to support entry keys or designated a list entry or list position by list number and entry key.

Action: Ensure that you are connected to the intended structure. The use of keys for a structure is determined by the REFOPTION keyword on the IXLCONN macro.

8 xxxx0851 Equate Symbol: IXLRSNCODENOSUSPENDISABLE

Meaning: Program error. The request failed because MODE=SYNCSUSPEND was specified, but the caller is disabled and cannot be suspended.

Action: Either specify another MODE value, or become enabled (release the CPU lock), then reissue the request.

8 xxxx0864 Equate Symbol: IXLRSNCODEBADBUFSIZE

Meaning: Program error. The size of the BUFFER area or the buffer areas specified by BUFLIST is not large enough to contain the data being read. No data is returned.

Action: If more space is available, specify a larger buffer size, and reissue the request.

8 xxxx0865 Equate Symbol: IXLRSNCODEBADBUFSPEC

Meaning: Program error. There is an error in the buffer specification.

Action: Check the following:
  • The requirements for BUFLIST or BUFFER.
  • Buffer pointer(s) in the BUFLIST.
  • Buffer boundaries.
8 xxxx0866 Equate Symbol: IXLRSNCODEBADBUFKEY

Meaning: Program error. The buffer storage key specified by BUFSTGKEY is incorrect or BUFSTGKEY was not specified and the PSW key does not match the key of the buffers.

The data cannot be stored in the specified buffer area.

Action: Check the following:
  • Determine if the key of the storage being used for the buffers is different from the PSW key.
  • If BUFSTGKEY was specified, verify that the key was put in the correct bits (see the explanation of this parameter for more information).
  • If you are calling IXLLIST in AR-mode, SYSSTATE ASCENV=AR must be issued before the IXLLIST macro.
8 xxxx0867 Equate Symbol: IXLRSNCODEBADBUFLIST

Meaning: Program error. The 128-byte storage area specified by BUFLIST is not addressable.

Action: Ensure that the address specified by BUFLIST is valid.

8 xxxx08AD Equate Symbol: IXLRSNCODEBADHIGHSHAREDVIRT

Meaning: Program error. The request specified a high shared virtual storage area (above 2GB).

Action: None required.

C xxxx0C06 Equate Symbol: IXLRSNCODENOCONN
Meaning: Environmental error. This system does not have connectivity to the coupling facility that contains the list structure. Possible reasons for this are:
  • The operator issued VARY PATH,OFFLINE.
  • The operator issued CONFIG CHP,OFFLINE.
  • Hardware errors to the coupling facility.
  • Facility or path failure to the coupling facility.

Action: Begin rebuilding the structure on a different coupling facility, or disconnect from the structure.

C xxxx0C13 Equate Symbol: IXLRSNCODEREQPURGED
Meaning: Environmental error. The request was purged prior to completion of the request. Possible reasons include:
  • The connector failed.
  • The connector disconnected.
  • The requestor failed.
  • The request was purged by IXLPURGE.
  • Requests were purged when the connector provided an IXLEERSP response for the Rebuild Stop or Rebuild Cleanup event.
  • The secondary address space was no longer valid.

Action: None if this is expected. Otherwise, determine why the connector failed.

C xxxx0C14 Equate Symbol: IXLRSNCODESTATUSUNKNOWN

Meaning: Environmental error. The request has completed, but the final disposition of the request cannot be determined. The answer area (ANSAREA) fields do not contain valid information.

Action:
  • Verify the validity of your data by comparing the expected results with what is in the coupling facility.
  • Consider running rebuild processing to move the structure to attempt to protect it from further errors of this kind.
C xxxx0C25 Equate Symbol: IXLRSNCODESTRFAILURE

Meaning: Environmental error. The list structure failed prior to completion of the request.

Action: Either rebuild or disconnect from the structure.

C xxxx0C68 Equate Symbol: IXLRSNCODEBADREQCFLEVEL

Meaning: Environmental error. The request type is not permitted for the level of coupling facility in which the target structure is allocated.

Action: Either disconnect from the structure (using IXLDISC) or initiate a rebuild of the structure, if allowed (using IXLREBLD) in a coupling facility of the correct CFLEVEL.

C xxxx0CA0 Equate Symbol: IXLRSNCODEQUIESCEDSUSPENDFAIL

Meaning: Environmental error. The request is failed because the structure is quiesced for a system-managed process and SUSPEND=FAIL is specified on the IXLCONN.

Action: None, if this is expected.

C xxxxFFFF Equate Symbol: IXLRSNCODENOTAVAILABLE

Meaning: Environmental error. XES functions are not available. This could occur because the coupling facility hardware necessary to provide XES functions is not present.

Action: Re-IPL the system, or follow your particular failure management protocol.

10 xxxx10xx Meaning: System error. XES processing failure. The state of the involved structure and the disposition of the request are unpredictable. The answer area (ANSAREA) fields do not contain valid information.

Action: Contact the IBM® support center.