You cannot issue the IXLCONN macro from the master address space.
The maximum number of connections to a structure in the coupling
facility depends on:
The number of CONNECT records in the active CFRM policy.
The
default number of CONNECT records you can specify is 32; the maximum
allowed is 255.
The limit imposed by the coupling facility control code.
This limit is model-dependent. CFLEVEL=0 or 1 for a coupling
facility allows up to 32 connections for all structure types. For
CFLEVEL values that are in the range CFLEVEL=2 to CFLEVEL=16 including
a CFLEVEL=16 coupling facility allows up to 255 connections for a
cache structure and 32 connections for a list or lock structure.
A CFLEVEL=17 or higher coupling facility allows up to 255 connections
for all structure types.
The address space limit of 128 PASN–AL entries
for serialized structures per address space. (The lock structure and
the serialized list structure are “serialized structures.")
The application-specified value of the NUMUSERS or
MAXCONN keyword on a request to connect to a list structure.
The application-specified value of the NUMUSERS or
MAXCONN keywords on a request to connect to a lock structure.
The lock table entry size for serialized list and
lock structures. The architected z/OS® limit
on the lock table entry size for serialized list structures limits
the number of connectors that can be represented by the lock table
entry to 127. The architected z/OS limit
on the lock table entry size for lock structures limits the number
of connectors that can be represented by the lock table entry to 247.