The parameter descriptions for REQUEST=SET_RECLVCTR are listed
in alphabetical order. Default values are underlined: - REQUEST=SET_RECLVCTR
- Use this input parameter to specify that the reclaiming vector
(RECLVCTR) for the specified storage class (STGCLASS) be activated
or deactivated.
- ,ANSAREA=NO_ANSAREA
- ,ANSAREA=ansarea
- Use this output parameter to specify an answer area to contain
information returned from the request. The format of the answer area is described
by the IXLYCAA mapping macro.
To Code: Specify the RS-type
name or address (using a register from 2 to 12) of an area (with a
length of ANSLEN) where the information returned by the request will
be put.
- ,ANSLEN=anslen
- Use this input parameter to specify the size of the storage area
specified by ANSAREA.
Use either CAALEVEL0LEN or CAALEVEL1LEN of the IXLYCAA mapping
macro to determine
the minimum size of the answer area. The answer area length must
be at least large enough to accomodate the level of the IXLYCAA mapping
appropriate to the requested function. When the value of PLISTVER
is 0 — 3, the minimum answer area length is CAALEVEL0LEN; when
the value of PLISTVER is 4 — 6, the minimum answer area length
is CAALEVEL1LEN.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 2-byte field that contains the length of the answer
area (ANSAREA).
- ,CONTOKEN=contoken
- Use this input parameter to specify the connect token that was
returned by the IXLCONN service in the IXLCONN answer area, mapped
by IXLYCONA. The connect token uniquely identifies your connection
to the cache structure, and must be specified on each IXLCACHE invocation.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 16-byte field that contains the connect token.
- ,MF=S
- ,MF=(L,mfctrl)
- ,MF=(L,mfctrl,mfattr)
- ,MF=(L,mfctrl,0D)
- ,MF=(E,mfctrl)
- ,MF=(E,mfctrl,COMPLETE)
- Use MF=S to specify the standard form of the macro, which builds
an inline parameter list and generates the macro invocation to transfer
control to the service.
Use MF=L to specify the list form of the macro. Use the list form
together with the execute form of the macro for applications that
require reentrant code. The list form defines an area of storage that
the execute form uses to store the parameters. Only the PLISTVER parameter
can be coded with the list form of the macro.
Use MF=E to specify the execute form of the macro. Use the execute
form together with the list form of the macro for applications that
require reentrant code. The execute form stores the parameters into
the storage area defined by the list form, and generates the macro
invocation to transfer control to the service.
- ,mfctrl
- Use this output parameter to specify a storage area to contain
the parameters.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of the parameter list.
- ,mfattr
- Use this input parameter to specify the name of a 1- to 60-character
string that can contain any value that is valid on an assembler DS
pseudo-op. You can use this parameter to force boundary alignment
of the parameter list. If you do not code mfattr, the system
provides a value of 0D, which forces the parameter list to a doubleword
boundary.
- ,COMPLETE
- Use this input parameter to require that the system check for
required parameters and supply defaults for omitted optional parameters.
Note: In the macro expansion you might see some defaults for optional
parameters that are not documented here. The ones that are not documented
do not have any effect on the macro. For example, if SMILE=var were
an optional parameter and the default is SMILE=NO_SMILE then it would
not be documented. However, if the default was SMILE=:-), then it
would be documented because a value would be the default.
- ,MODE=SYNCSUSPEND
- ,MODE=SYNCECB
- ,MODE=SYNCEXIT
- ,MODE=SYNCTOKEN
- ,MODE=ASYNCECB
- ,MODE=ASYNCEXIT
- ,MODE=ASYNCTOKEN
- ,MODE=ASYNCNORESPONSE
- Use this input parameter to specify:
- Whether the request is to be performed synchronously or asynchronously
- How you wish to be notified of request completion if the request
is processed asynchronously.
See z/OS MVS Programming: Sysplex Services Guide for
more information on understanding
synchronous and asynchronous cache operations.
- MODE=SYNCSUSPEND
- The request processes synchronously. If necessary, the request
is suspended until it can complete synchronously. To use this option,
your program must be enabled for I/O and external interrupts.
- MODE=SYNCECB
- The request processes synchronously if possible. If the request
processes asynchronously, the ECB specified by REQECB is posted when
the request completes.
- MODE=SYNCEXIT
- The request processes synchronously if possible. If the request
processes asynchronously, your complete exit is given control when
the request completes.
- MODE=SYNCTOKEN
- The request processes synchronously if possible. If the request
processes asynchronously, an asynchronous request token is returned
to the area specified by REQTOKEN. Use the returned request token
on the IXLFCOMP macro to determine whether your request has completed.
Note: ANSAREA is a required parameter when MODE=SYNCTOKEN is specified.
- MODE=ASYNCECB
- The request processes asynchronously. The ECB specified by REQECB
is posted when the request completes.
- MODE=ASYNCEXIT
- The request processes asynchronously. Your complete exit is given
control when the request completes.
- MODE=ASYNCTOKEN
- The request processes asynchronously. An asynchronous request
token is returned to the area specified by REQTOKEN. Use the returned
request token on the IXLFCOMP macro to determine whether your request
has completed.
Note: ANSAREA is a required parameter when MODE=ASYNCTOKEN is specified.
- MODE=ASYNCNORESPONSE
- The request processes asynchronously. No notification of request
completion is provided.
- ,PLISTVER=IMPLIED_VERSION
- ,PLISTVER=MAX
- ,PLISTVER=plistver
- Use this input parameter to specify the version of the macro.
See Understanding IXLCACHE Version Support for a description of the
options available with PLISTVER.
- ,RECLVCTR=NO_RECLVCTR
- ,RECLVCTR=reclvctr
- Use this input parameter to define and activate a reclaiming vector.
The RECLVCTR area must be arranged as follows:
- The area must contain, starting at offset zero, a fully initialized
array of halfwords, each corresponding to a storage class. (There
must be one halfword for each storage class defined for the structure.)
The relative position of a halfword in the array determines which
storage class that halfword is associated with. For instance, the
first halfword in the array is associated with storage class one,
the second halfword is associated with storage class two, and so forth.
- Each halfword in the array must contain the reclaiming count for
its associated storage class. You can avoid reclaims from a storage
class by placing zero in the appropriate halfword.
If the specified reclaiming vector is not already active
and a REPEAT factor of zero is specified, the REPEAT factor is ignored.
If the reclaiming vector is already active, a zero REPEAT factor deactivates
the reclaiming vector.
To Code: Specify the RS-type
name or address (using a register from 2 to 12) of a storage area
(with a length of double the number of storage classes defined for
the structure on the IXLCONN macro, keyword NUMSTGCLASS) that contains
the reclaiming vectors.
- ,REPEAT=repeat
- Use this input parameter to specify the repeat factor for the
reclaiming vector being activated (or deactivated). The repeat factor
defines the number of passes through the reclaiming vector before
the vector deactivates. The specified value must fall within the range
0 to 65535, inclusive. Specifying a repeat factor of zero causes the
active reclaiming vector for the specified storage class to be deactivated.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 2-byte field that contains the repeat factor.
- ,REQDATA=NO_REQDATA
- ,REQDATA=reqdata
- Use this input parameter with MODE=SYNCEXIT or MODE=ASYNCEXIT
to pass any data you choose to the complete exit. The exit will get
control only if the request is processed asynchronously.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of an 8-byte field that contains the data to be passed
to the complete exit.
- ,REQECB=reqecb
- Use this output parameter with either MODE=SYNCECB or MODE=ASYNCECB
to specify the address of an ECB, which is to be posted when the request
completes if the request was processed asynchronously.
Before coding REQECB, you must ensure that:
- You initialize the ECB before you issue the request.
- The ECB resides in either common storage or the home address space
where IXLCONN was issued.
- Any tasks that wait for the ECB to be posted reside in the home
address space where IXLCONN was issued.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that contains the address of the ECB
to be posted when the request completes. The ECB must be aligned on
a fullword boundary.
- ,REQID=NO_REQID
- ,REQID=reqid
- Use this input parameter to specify a user-defined request identifier
to be associated with the request. You can specify this request identifier
on the IXLPURGE macro to cancel a request that has not yet been processed.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of an 8-byte field that contains the user-defined request
identifier.
- ,REQTOKEN=reqtoken
- Use this output parameter with either MODE=SYNCTOKEN or MODE=ASYNCTOKEN
to specify the address of a storage area to receive the request token
that is returned when the request will be processed asynchronously.
This token, which uniquely identifies the request, must be used as
input to the IXLFCOMP macro, which you use to determine if the request
has completed.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 16-byte field where the system will put the request
token.
- ,RETCODE=retcode
- Use this output parameter to specify a field to contain the return
code. (The return code is also returned in register 15.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the return code
when the request has completed.
- ,RSNCODE=rsncode
- Use this output parameter to specify a field to contain the reason
code returned, if applicable. (The reason code is also returned in
register 0.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the reason code
(if any) when the request has completed.
- ,STGCLASS=stgclass
- Use this input parameter to specify the storage class for which
a reclaim vector is to be activated or deactivated.
To Code: Specify
the RS-type name or address (using a register from 2 to 12) of a 1-byte
field that contains the storage class.
|