The parameter descriptions for REQUEST=PROCESS_REFLIST are listed
in alphabetical order. Default values are underlined:
- REQUEST=PROCESS_REFLIST
- Use this input parameter to specify that the data items listed
by name in the storage areas specified by BUFLIST or BUFFER be processed
as having been recently referenced.
- ,ANSAREA=NO_ANSAREA
- ,ANSAREA=ansarea
- Use this output parameter to specify an answer area to contain
information returned from the request. The format of the answer area is described by
the IXLYCAA mapping macro.
To Code: Specify
the RS-type name or address (using a register from 2 to 12) of an
area (with a length of ANSLEN) where the information returned from
the request will be put.
- ,ANSLEN=anslen
- Use this input parameter to specify the size of the storage area
specified by ANSAREA.
Use either CAALEVEL0LEN or CAALEVEL1LEN of the IXLYCAA mapping
macro to determine
the minimum size of the answer area. The answer area length must
be at least large enough to accomodate the level of the IXLYCAA mapping
appropriate to the requested function. When the value of PLISTVER
is 0 — 3, the minimum answer area length is CAALEVEL0LEN; when
the value of PLISTVER is 4 — 6, the minimum answer area length
is CAALEVEL1LEN.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 2-byte field that contains the length of the answer
area (ANSAREA).
- ,BUFADDRSIZE=31
- ,BUFADDRSIZE=64
- Use this input parameter to specify whether a 31-bit or a 64-bit
address is specified by a BUFLIST entry.
- 31
- The entry in BUFLIST is 31 bits in size.
- 64
- The entry in BUFLIST is 64 bits in size.
- ,BUFADDRTYPE=VIRTUAL
- ,BUFADDRTYPE=REAL
- Use this input parameter to specify whether the buffer addresses
specified in the BUFLIST list are virtual storage or real storage
addresses.
- VIRTUAL
- The buffer addresses are virtual storage addresses. The virtual
storage can be pageable or nonpageable. See the PAGEABLE parameter
for information about managing storage binds when specifying virtual
storage addresses.
- REAL
- The buffer addresses are real storage addresses.
It is the caller's responsibility to manage the binds between the
data buffer virtual storage and the real storage addresses provided.
The caller must ensure that the data buffer virtual storage remains
bound to the real storage addresses provided until the request completes.
- ,BUFALET=NO_BUFALET
- ,BUFALET=bufalet
- Use this input parameter to specify an access list entry token
(ALET) to be used in referencing all of the buffers specified by BUFLIST.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that contains the ALET.
- ,BUFFER=buffer
- Use this input parameter to specify a buffer area to contain
a list of entry names to be processed.
You must ensure that the
storage area specified by BUFFER:
- Is a multiple of 4096 bytes.
- Is less than or equal to 65536 bytes.
- Starts on a 4096-byte boundary.
- Does not start below storage address 512.
The buffers must be formatted to contain 16-byte elements,
starting at offset zero. Each 16-byte element must contain a name
to be processed.
See the NUMNAMES description to specify the
number of data items to be processed, and the BUFSIZE description
to specify the size of the buffer.
To Code: Specify
the RS-type name or address (using a register from 2 to 12) of an
area (with a length of BUFSIZE) that contains the list of names to
be processed.
- ,BUFLIST=buflist
- Use this input parameter to specify a list of buffers to hold
a list of names to be processed. BUFLIST specifies a 128-byte storage
area that consists of a list of 0 to 16 buffer addresses.
The
format of the list is a set of 8-byte elements. The BUFADDRSIZE keyword
denotes whether four or eight bytes of the element are used.
- If BUFADDRSIZE=31 is specified, then the first four bytes of each
element are reserved space and the last four bytes contain the address
of the buffer.
- If BUFADDRSIZE=64 is specified, then the full eight bytes specify
the address of the buffer.
The BUFLIST buffers must:
- Reside in the same address space or same data space.
- Be 4096 bytes.
- Start on a 4096-byte boundary.
- Not start below storage address 512.
- Consist of 16-byte elements, starting at offset zero. Each 16-byte
element should contain a name to be processed. The named element must
reside in the storage class specified by STGCLASS.
Note: The buffers do not have to be contiguous
in storage. Cache services treat BUFLIST buffers as a single buffer,
even if the buffers are not contiguous.
See the
NUMNAMES description to specify the number of data items to be processed,
and the BUFNUM parameter to specify the number of buffers in the buffer
list.
To Code: Specify the RS-type name
or address (using a register from 2 to 12) of a 128-byte field that
contains a list of buffer addresses.
- ,BUFNUM=bufnum
- Use this input parameter to specify the number of buffers in
the BUFLIST list. Valid BUFNUM values are from 0 to 16. A value of
zero indicates that no entries will be processed.
To
Code: Specify the RS-type name or address (using a register from
2 to 12) of a 1-byte field that contains the number of buffers in
the buffer list.
- ,BUFSIZE=bufsize
- Use this input parameter to specify the size of the BUFFER area.
See the BUFFER parameter description for valid buffer sizes.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a fullword field that contains the size of the buffer
(BUFFER) in bytes.
- ,BUFSTGKEY=CALLERS_KEY
- ,BUFSTGKEY=bufstgkey
- Use this input parameter to specify a storage key that you define
and use when referencing the buffers specified by BUFLIST or the buffer
specified by BUFFER.
If you do not specify BUFSTGKEY, or if you specify BUFSTGKEY=CALLERS_KEY,
all references to the buffer(s) are performed using the caller's PSW
key.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of an 8-bit field that contains the storage key in the
format B'kkkkxxxx', where kkkk is the key and xxxx is ignored.
- ,CONTOKEN=contoken
- Use this input parameter to specify the connect token that was
returned by the IXLCONN service in the IXLCONN answer area, mapped
by IXLYCONA. The connect token uniquely identifies your connection
to the cache structure, and must be specified on each IXLCACHE invocation.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 16-byte field that contains the connect token.
- ,MF=S
- ,MF=(L,mfctrl)
- ,MF=(L,mfctrl,mfattr)
- ,MF=(L,mfctrl,0D)
- ,MF=(E,mfctrl)
- ,MF=(E,mfctrl,COMPLETE)
- Use MF=S to specify the standard form of the macro, which builds
an inline parameter list and generates the macro invocation to transfer
control to the service.
Use MF=L to specify the list form of the macro. Use the list form
together with the execute form of the macro for applications that
require reentrant code. The list form defines an area of storage that
the execute form uses to store the parameters. Only the PLISTVER parameter
can be coded with the list form of the macro.
Use MF=E to specify the execute form of the macro. Use the execute
form together with the list form of the macro for applications that
require reentrant code. The execute form stores the parameters into
the storage area defined by the list form, and generates the macro
invocation to transfer control to the service.
- ,mfctrl
- Use this output parameter to specify a storage area to contain
the parameters.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of the parameter list.
- ,mfattr
- Use this input parameter to specify the name of a 1- to 60-character
string that can contain any value that is valid on an assembler DS
pseudo-op. You can use this parameter to force boundary alignment
of the parameter list. If you do not code mfattr, the system
provides a value of 0D, which forces the parameter list to a doubleword
boundary.
- ,COMPLETE
- Use this input parameter to require that the system check for
required parameters and supply defaults for omitted optional parameters.
Note: In the macro expansion you might see some defaults for optional
parameters that are not documented here. The ones that are not documented
do not have any effect on the macro. For example, if SMILE=var were
an optional parameter and the default is SMILE=NO_SMILE then it would
not be documented. However, if the default was SMILE=:-), then it
would be documented because a value would be the default.
- ,MODE=SYNCSUSPEND
- ,MODE=SYNCECB
- ,MODE=SYNCEXIT
- ,MODE=SYNCTOKEN
- ,MODE=ASYNCECB
- ,MODE=ASYNCEXIT
- ,MODE=ASYNCTOKEN
- Use this input parameter to specify:
- Whether the request is to be performed synchronously or asynchronously
- How you wish to be notified of request completion if the request
is processed asynchronously.
See z/OS MVS Programming: Sysplex Services Guide for
more information on understanding
synchronous and asynchronous cache operations.
- SYNCSUSPEND
- The request processes synchronously. If necessary, the request
is suspended until it can complete synchronously. To use this option,
your program must be enabled for I/O and external interrupts.
- SYNCECB
- The request processes synchronously if possible. If the request
processes asynchronously, the ECB specified by REQECB is posted when
the request completes.
- SYNCEXIT
- The request processes synchronously if possible. If the request
processes asynchronously, your complete exit is given control when
the request completes.
- SYNCTOKEN
- The request processes synchronously if possible. If the request
processes asynchronously, an asynchronous request token is returned
to the area specified by REQTOKEN. Use the returned request token
on the IXLFCOMP macro to determine whether your request has completed.
Note: ANSAREA is a required parameter when MODE=SYNCTOKEN is specified.
- ASYNCECB
- The request processes asynchronously. The ECB specified by REQECB
is posted when the request completes.
- ASYNCEXIT
- The request processes asynchronously. Your complete exit is given
control when the request completes.
- ASYNCTOKEN
- The request processes asynchronously. An asynchronous request
token is returned to the area specified by REQTOKEN. Use the returned
request token on the IXLFCOMP macro to determine whether your request
has completed.
Note: ANSAREA is a required parameter when MODE=ASYNCTOKEN is specified.
- ,NUMNAMES=numnames
- Use this input parameter to specify the number of names contained
in the BUFFER area or BUFLIST buffers.
To Code: Specify
the RS-type name or address (using a register from 2 to 12) of a 2-byte
field that contains the number of names.
- ,PAGEABLE=YES
- ,PAGEABLE=NO
- Use this input parameter to identify whether the storage areas
specified by BUFFER or BUFLIST are in pageable or potentially pageable
storage.
- YES
- Specify this option to indicate that the BUFFER or BUFLIST buffers
reside in pageable virtual storage. XES performs the required page
fixing to fix the buffers in real storage while the cache or list
request transfers data to or from the coupling facility.
This includes storage obtained from pageable subpools, disabled
reference (DREF) storage, and may include storage that has the potential
to become pageable during the processing of a request. (An example
is address space storage owned by any swappable address space, for
which a PGSER FIX has been successfully processed, but for which the
owning address space gets swapped during processing of a cache or
list request.) This does not include implicitly non-pageable storage
(for example, storage obtained from non-pageable subpools).
The system takes responsibility for managing binds to central storage
for the duration of the cache or list request, regardless of what
address space owns the storage or whether the storage-owning address
space is swappable or nonswappable. The storage can be owned by any
address space.
High shared virtual storage areas (above 2GB) may not
be used.
- NO
- Specify this option to indicate that the BUFFER or BUFLIST buffers
reside in non-pageable virtual storage. XES does not page fix the
buffers in real storage.
This includes implicitly non-pageable storage areas (for example,
storage obtained from non-pageable subpools), and may include storage
that has the potential to become pageable during the processing of
a request (An example is address space storage owned by any swappable
address space, for which a PGSER FIX has been successfully processed,
but for which the owning address space gets swapped-out during processing
of a cache or list request.)
The system takes responsibility for managing binds to central storage
for the duration of the cache or list request, if and only if the
non-pageable storage is owned by either the requestor's address space
or the connector's address space. If the storage is owned by any other
address space, then the invoker is responsible for ensuring that the
virtual storage remains non-pageable for the duration of the request
(including the case in which the storage is owned by a swappable address
space that is swapped during processing of an IXLCACHE or IXLLIST
request). Subject to this consideration, the storage can be owned
by any address space. See z/OS MVS Programming: Sysplex Services Guide.
- ,PLISTVER=IMPLIED_VERSION
- ,PLISTVER=MAX
- ,PLISTVER=plistver
- Use this input parameter to specify the version of the macro.
See Understanding IXLCACHE Version Support for a description of the options available
with PLISTVER.
- ,REQDATA=NO_REQDATA
- ,REQDATA=reqdata
- Use this input parameter with MODE=SYNCEXIT or MODE=ASYNCEXIT
to pass any data you choose to the complete exit. The exit will get
control only if the request is processed asynchronously.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of an 8-byte field that contains the data to be passed
to the complete exit.
- ,REQECB=reqecb
- Use this output parameter with either MODE=SYNCECB or MODE=ASYNCECB
to specify the address of an ECB, which is to be posted when the request
completes if the request was processed asynchronously.
Before coding REQECB, you must ensure that:
- You initialize the ECB before you issue the request.
- The ECB resides in either common storage or the home address space
where IXLCONN was issued.
- Any tasks that wait for the ECB to be posted reside in the home
address space where IXLCONN was issued.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that contains the address of the ECB
to be posted when the request completes. The ECB must be aligned on
a fullword boundary.
- ,REQID=NO_REQID
- ,REQID=reqid
- Use this input parameter to specify a user-defined request identifier
to be associated with the request. You can specify this request identifier
on the IXLPURGE macro to cancel a request that has not yet been processed.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of an 8-byte field that contains the user-defined request
identifier.
- ,REQTOKEN=reqtoken
- Use this output parameter with either MODE=SYNCTOKEN or MODE=ASYNCTOKEN
to specify the address of a storage area to receive the request token
that is returned when the request will be processed asynchronously.
This token, which uniquely identifies the request, must be used as
input to the IXLFCOMP macro, which you use to determine if the request
has completed.
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 16-byte field where the system will put the request
token.
- ,RETCODE=retcode
- Use this output parameter to specify a field to contain the return
code. (The return code is also returned in register 15.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the return code
when the request has completed.
- ,RSNCODE=rsncode
- Use this output parameter to specify a field to contain the reason
code returned, if applicable. (The reason code is also returned in
register 0.)
To Code: Specify the RS-type name or address (using a register
from 2 to 12) of a 4-byte field that will contain the reason code
(if any) when the request has completed.
- ,STGCLASS=stgclass
- Use this input parameter to specify the storage class to which
the data items to be processed must be assigned.
To
Code: Specify the RS-type name or address (using a register from
2 to 12) of a 1-byte field that contains the storage class.
|