z/OS MVS Programming: Sysplex Services Reference
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Parameter Descriptions

z/OS MVS Programming: Sysplex Services Reference
SA38-0658-00

The parameter descriptions for REQUEST=CASTOUT_DATALIST are listed in alphabetical order. Default values are underlined:
REQUEST=CASTOUT_DATALIST
Use this input parameter to:
  • Specify that a cast-out lock be obtained for the set of data items identified by CASTOUTLIST, and that the named data items be read into the storage areas specified BUFFER or BUFLIST, DEIBAREA, and/or ADJAREA.
  • Update the directory entry change bit for each data item to indicate that each entry contains unchanged subsystem data.
,ADJAREA=NO_ADJAREA
,ADJAREA=adjarea
Use this output parameter to specify a storage area to contain the adjunct data that was read from the first processed entry.

If the structure supports adjunct data and ADJAREA is not specified, or if ADJAREA=NO_ADJAREA is specified, then no adjunct data is returned for the first entry processed.

If the structure does not support adjunct data and ADJAREA is specified, then entry data is returned, but no adjunct data is returned for every entry processed. CAAADJAREAVALID, which is returned in ANSAREA, will indicate that adjunct data did not exist.

(Adjunct areas for a structure are established through the IXLCONN macro.)

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 64-byte virtual storage area that the adjunct data will be read into.

,ANSAREA=NO_ANSAREA
,ANSAREA=ansarea
Use this output parameter to specify an answer area to contain information returned from the request. The format of the answer area is described by the IXLYCAA mapping macro.

To Code: Specify the RS-type name or address (using a register from 2 - 12) of an area (with a length of ANSLEN) where the information returned from the request will go.

,ANSLEN=anslen
Use this input parameter to specify the size of the storage area specified by ANSAREA.

Use either CAALEVEL0LEN or CAALEVEL1LEN of the IXLYCAA mapping macro to determine the minimum size of the answer area. The answer area length must be at least large enough to accomodate the level of the IXLYCAA mapping appropriate to the requested function. When the value of PLISTVER is 0 — 3, the minimum answer area length is CAALEVEL0LEN; when the value of PLISTVER is 4 — 6, the minimum answer area length is CAALEVEL1LEN.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 2-byte field that contains the length of the answer area (ANSAREA).

,BUFADDRSIZE=31
,BUFADDRSIZE=64
Use this input parameter to specify whether a 31-bit or a 64-bit address is specified by a BUFLIST entry.
31
The entry in BUFLIST is 31 bits in size.
64
The entry in BUFLIST is 64 bits in size.
,BUFADDRTYPE=VIRTUAL
,BUFADDRTYPE=REAL
Use this input parameter to specify whether the buffer addresses specified in the BUFLIST list are virtual storage or real storage addresses.
VIRTUAL
The buffer addresses are virtual storage addresses. The virtual storage can be pageable or nonpageable. See the PAGEABLE parameter for information about managing storage binds when specifying virtual storage addresses.
REAL
The buffer addresses are real storage addresses.

It is the caller's responsibility to manage the binds between the data buffer virtual storage and the real storage addresses provided. The caller must ensure that the data buffer virtual storage remains bound to the real storage addresses provided until the request completes.

,BUFALET=NO_BUFALET
,BUFALET=bufalet
Use this input parameter to specify an access list entry token (ALET) to be used in referencing all of the buffers specified by BUFLIST.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 4-byte field that contains the ALET.

,BUFFER=buffer
Use this output parameter to specify a buffer area to hold the data area from the first processed name in the CASTOUTLIST followed by the DEIB, adjunct data if it exists, and the data area from the second processed name in the CASTOUTLIST. This will continue until the end of the CASTOUTLIST pointed to by ENDINDEX is reached or until the request completes prematurely for some other reason.

Only 31-bit addressable virtual storage areas (below 2GB) are supported by the BUFFER specification. High virtual storage areas (above 2GB) can only be specified via the BUFLIST specification.

You must ensure that the storage area specified by BUFFER:
  • Is a multiple of 4096 bytes.
  • Is less than or equal to 65536 bytes.
  • Starts on a 4096-byte boundary.

See the BUFSIZE parameter description for defining the size of the buffer.

See z/OS MVS Programming: Sysplex Services Guide for more information on buffers.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of an area (with a length of BUFSIZE) to receive the entries requested.

BUFLIST=buflist
Use this output parameter to specify a list of buffers to hold the data area from the first processed name in the CASTOUTLIST followed by the DEIB, adjunct data if it exists, and the data area from the second processed name in the CASTOUTLIST. This will continue until the end of the CASTOUTLIST pointed to by ENDINDEX is reached or until the request completes prematurely for some other reason. BUFLIST specifies a 128-byte storage area that consists of a list of 0 to 16 buffer addresses.

Either 31-bit addressable (below 2GB) or 64-bit addressable (above 2GB) real or virtual storage areas are supported for the BUFLIST specification, depending on the specification for the BUFADDRTYPE and BUFFADDRSIZE keywords. However, pageable high shared virtual storage areas (above 2GB) may not be used.

The format of the list is a set of 8-byte elements. The BUFADDRSIZE keyword denotes whether four or eight bytes of the element are used.
  • If BUFADDRSIZE=31 is specified, then the first four bytes of each element are reserved space and the last four bytes contain the address of the buffer.
  • If BUFADDRSIZE=64 is specified, then the full eight bytes specify the address of the buffer.
The BUFLIST buffers must:
  • Reside in the same address space or data space.
  • Be 4096 bytes.
  • Start on a 4096-byte boundary.
Note: The buffers do not have to be contiguous in storage. Cache services treat BUFLIST buffers as a single buffer even if the buffers are not contiguous.

See the BUFNUM parameter to specify the number of buffers in the buffer list.

See z/OS MVS Programming: Sysplex Services Guide for more information on buffers.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 128-byte field that contains a list of buffer addresses.

,BUFNUM=bufnum
Use this input parameter to specify the number of buffers in the BUFLIST list. Valid BUFNUM values are from 0 to 16. A value of zero indicates that no data is to be read into the buffers.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 1-byte field that contains the number of buffers (0 to 16) in the list (BUFLIST).

,BUFSIZE=bufsize
Use this input parameter to specify the size of the BUFFER area. See the BUFFER parameter description for valid buffer sizes.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a fullword field that contains the size of the buffer (BUFFER) in bytes.

,BUFSTGKEY=CALLERS_KEY
,BUFSTGKEY=bufstgkey
Use this input parameter to specify a storage key that you define and use when referencing the buffers specified by BUFLIST or the buffer specified by BUFFER.

If you do not specify BUFSTGKEY, or if you specify BUFSTGKEY=CALLERS_KEY, all references to the buffer(s) are performed using the caller's PSW key.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of an 8-bit field that contains the storage key in the format B'kkkkxxxx', where kkkk is the key and xxxx is ignored.

,CASTOUTLIST=castoutlist
Use this input parameter to specify a 128-byte area that contains a list of up to 8 16-byte entry names to be locked for castout processing.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 128-byte field containing a list of entry names.

,CONTOKEN=contoken
Use this input parameter to specify the connect token that was returned by the IXLCONN service in the IXLCONN answer area, mapped by IXLYCONA. The connect token uniquely identifies your connection to the cache structure, and must be specified on each IXLCACHE invocation.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 16-byte field that contains the connect token.

,DEIBAREA=deibarea
Use this output parameter to specify an output area to contain the DEIB from the first entry processed in CASTOUTLIST, as specified by STARTINDEX. The DEIBs for the rest of the entries will be returned in the data buffer specified by BUFFER or BUFLIST.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 128-byte field to contain the DEIB from the first entry processed.

,ENDINDEX=endindex
Use this input parameter to specify the ending index for the last entry in CASTOUTLIST to be processed. The index value must be greater than or equal to the value specified for STARTINDEX, but less than or equal to 8.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a halfword field containing the ending index value.

,MF=S
,MF=(L,mfctrl)
,MF=(L,mfctrl,mfattr)
,MF=(L,mfctrl,0D)
,MF=(E,mfctrl)
,MF=(E,mfctrl,COMPLETE)
Use MF=S to specify the standard form of the macro, which builds an inline parameter list and generates the macro invocation to transfer control to the service.

Use MF=L to specify the list form of the macro. Use the list form together with the execute form of the macro for applications that require reentrant code. The list form defines an area of storage that the execute form uses to store the parameters. Only the PLISTVER parameter can be coded with the list form of the macro.

Use MF=E to specify the execute form of the macro. Use the execute form together with the list form of the macro for applications that require reentrant code. The execute form stores the parameters into the storage area defined by the list form, and generates the macro invocation to transfer control to the service.
,mfctrl
Use this output parameter to specify a storage area to contain the parameters.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of the parameter list.

,mfattr
Use this input parameter to specify the name of a 1- to 60-character string that can contain any value that is valid on an assembler DS pseudo-op. You can use this parameter to force boundary alignment of the parameter list. If you do not code mfattr, the system provides a value of 0D, which forces the parameter list to a doubleword boundary.
,COMPLETE
Use this input parameter to require that the system check for required parameters and supply defaults for omitted optional parameters.
Note: In the macro expansion you might see some defaults for optional parameters that are not documented here. The ones that are not documented do not have any effect on the macro. For example, if SMILE=var were an optional parameter and the default is SMILE=NO_SMILE then it would not be documented. However, if the default was SMILE=:-), then it would be documented because a value would be the default.
,MODE=SYNCSUSPEND
,MODE=SYNCECB
,MODE=SYNCEXIT
,MODE=SYNCTOKEN
,MODE=ASYNCECB
,MODE=ASYNCEXIT
,MODE=ASYNCTOKEN
Use this input parameter to specify:
  • Whether the request is to be performed synchronously or asynchronously
  • How you wish to be notified of request completion if the request is processed asynchronously.
See z/OS MVS Programming: Sysplex Services Guide for more information on understanding synchronous and asynchronous cache operations.
SYNCSUSPEND
The request processes synchronously. If necessary, the request is suspended until it can complete synchronously. To use this option, your program must be enabled for I/O and external interrupts.
SYNCECB
The request processes synchronously if possible. If the request processes asynchronously, the ECB specified by REQECB is posted when the request completes.
SYNCEXIT
The request processes synchronously if possible. If the request processes asynchronously, your complete exit is given control when the request completes.
SYNCTOKEN
The request processes synchronously if possible. If the request processes asynchronously, an asynchronous request token is returned to the area specified by REQTOKEN. Use the returned request token on the IXLFCOMP macro to determine whether your request has completed.
Note: ANSAREA is a required parameter when MODE=SYNCTOKEN is specified.
ASYNCECB
The request processes asynchronously. The ECB specified by REQECB is posted when the request completes.
ASYNCEXIT
The request processes asynchronously. Your complete exit is given control when the request completes.
ASYNCTOKEN
The request processes asynchronously. An asynchronous request token is returned to the area specified by REQTOKEN. Use the returned request token on the IXLFCOMP macro to determine whether your request has completed.
Note: ANSAREA is a required parameter when MODE=ASYNCTOKEN is specified.
,PAGEABLE=YES
,PAGEABLE=NO
Use this input parameter to identify whether the storage areas specified by BUFFER or BUFLIST are in pageable or potentially pageable storage.
YES
Specify this option to indicate that the BUFFER or BUFLIST buffers reside in pageable virtual storage. XES performs the required page fixing to fix the buffers in real storage while the cache or list request transfers data to or from the coupling facility.

This includes storage obtained from pageable subpools, disabled reference (DREF) storage, and may include storage that has the potential to become pageable during the processing of a request. (An example is address space storage owned by any swappable address space, for which a PGSER FIX has been successfully processed, but for which the owning address space gets swapped during processing of a cache or list request.) This does not include implicitly non-pageable storage (for example, storage obtained from non-pageable subpools).

The system takes responsibility for managing binds to central storage for the duration of the cache or list request, regardless of what address space owns the storage or whether the storage-owning address space is swappable or nonswappable. The storage can be owned by any address space.

High shared virtual storage areas (above 2GB) may not be used.

NO
Specify this option to indicate that the BUFFER or BUFLIST buffers reside in non-pageable virtual storage. XES does not page fix the buffers in real storage.

This includes implicitly non-pageable storage areas (for example, storage obtained from non-pageable subpools), and may include storage that has the potential to become pageable during the processing of a request (An example is address space storage owned by any swappable address space, for which a PGSER FIX has been successfully processed, but for which the owning address space gets swapped-out during processing of a cache or list request.)

The system takes responsibility for managing binds to central storage for the duration of the cache or list request, if and only if the non-pageable storage is owned by either the requestor's address space or the connector's address space. If the storage is owned by any other address space, then the invoker is responsible for ensuring that the virtual storage remains non-pageable for the duration of the request (including the case in which the storage is owned by a swappable address space that is swapped during processing of an IXLCACHE or IXLLIST request). Subject to this consideration, the storage can be owned by any address space. See z/OS MVS Programming: Sysplex Services Guide.

,PLISTVER=IMPLIED_VERSION
,PLISTVER=MAX
,PLISTVER=plistver
Use this input parameter to specify the version of the macro. See Understanding IXLCACHE Version Support for a description of the options available with PLISTVER.
,PROCESSID=NO_PROCESSID
,PROCESSID=processid
Use this input parameter to specify a user-defined process identifier to be compared with the cast-out lock along with the connection identifier.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 1-byte field that contains the user-defined process identifier.

,REQDATA=NO_REQDATA
,REQDATA=reqdata
Use this input parameter with MODE=SYNCEXIT or MODE=ASYNCEXIT to pass any data you choose to the complete exit. The exit will get control only if the request is processed asynchronously.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of an 8-byte field that contains the data to be passed to the complete exit.

,REQECB=reqecb
Use this output parameter with either MODE=SYNCECB or MODE=ASYNCECB to specify the address of an ECB, which is to be posted when the request completes if the request was processed asynchronously.
Before coding REQECB, you must ensure that:
  • You initialize the ECB before you issue the request.
  • The ECB resides in either common storage or the home address space where IXLCONN was issued.
  • Any tasks that wait for the ECB to be posted reside in the home address space where IXLCONN was issued.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 4-byte field that contains the address of the ECB to be posted when the request completes. The ECB must be aligned on a fullword boundary.

,REQID=NO_REQID
,REQID=reqid
Use this input parameter to specify a user-defined request identifier to be associated with the request. You can specify this request identifier on the IXLPURGE macro to cancel a request that has not yet been processed.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of an 8-byte field that contains the user-defined request identifier.

,REQTOKEN=reqtoken
Use this output parameter with either MODE=SYNCTOKEN or MODE=ASYNCTOKEN to specify the address of a storage area to receive the request token that is returned when the request will be processed asynchronously. This token, which uniquely identifies the request, must be used as input to the IXLFCOMP macro, which you use to determine if the request has completed.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 16-byte field where the system will put the request token.

,RETCODE=retcode
Use this output parameter to specify a field to contain the return code. (The return code is also returned in register 15.)

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 4-byte field that will contain the return code when the request has completed.

,RSNCODE=rsncode
Use this output parameter to specify a field to contain the reason code returned, if applicable. (The reason code is also returned in register 0.)

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a 4-byte field that will contain the reason code (if any) when the request has completed.

,STARTINDEX=startindex
Use this input parameter to specify the index into CASTOUTLIST for the first entry to be processed. Valid STARTINDEX values are from 1 to the value of ENDINDEX. The first name in CASTOUTLIST block has index number 1.

To Code: Specify the RS-type name or address (using a register from 2 to 12) of a halfword field containing the starting index value.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014