Figure 1 lists the messages issued by ENQ
Monitor. They are self-explanatory.
For a complete list of all ISG messages, see z/OS MVS System Messages, Vol 9 (IGF-IWM).
AUDIT Messages
- ISGAU001 - INVALID REQUEST
modify command with wrong parameter
- ISGAU002 - FILTER TABLE NOT FOUND
program continues with the old filter table
- ISGAU002 - FILTER TABLE UNCHANGED
program continues with the old filter table
- ISGAU002 - SPECIFIED TABLE IS THE SAME AS THE
CURRENT TABLE
program continues with the old filter table
- ISGAU003 - MODIFY REQUEST DONE
- ISGAU004 - PARM FIELD NOT VALID
program ends during initialization
- ISGAU005 - AUDIT ALREADY ACTIVE
job submitted/started twice
- ISGAU007 - DDNAME FULL, PLEASE SAVE
dynamic switch to the other output data set
- ISGAU008 - FILTERxx ACTIVE - response to MODIFY,L
- ddname ACTIVE
- I=xxxxxx L=yyyyyyyy ENQ-DELAY=zzzzzzzz
- I=xxxxxx L=yyyyyyyy ENQ-DELAY=zzzzzzzz RESMIL=wwww
- ISGAU009 - DATA SET SWITCHED - response to MODIFY,S
- ISGAU009 - DATA SET NOT SWITCHED -
DATA SET MAY BE FULL
Output dataset will not switch
- ISGAU010 - FILTER RE-INITIALIZED - response to MODIFY,I=xx
- ISGAU012 - BOTH OUTPUT DATA SETS ARE FULL
- ISGAU013 - ISGAMCST NOT AVAILABLE
Figure 1. AUDIT Messages - ISGAU014 - CANNOT START MONITOR -
SYSTEM LX NOT AVAILABLE
ENQ Monitor cannot be started
- ISGAU014 - CANNOT START MONITOR -
NO COMMON STORAGE
ENQ Monitor cannot be started
- ISGAU014 - CANNOT START MONITOR -
NO PRIVATE STORAGE
ENQ Monitor cannot be started
- ISGAU014 - CANNOT START MONITOR - IWMEJOIN RSN = xxxxrcrs:
ENQ Monitor cannot be started because it can
not join the GRS Dependent WLM Enclave. Not
doing so can cause system problems so the
monitor is not allowed to be started. As this
is an internal error, search problem reporting
databases for a fix for the problem. If no fix
exists, contact the IBM Support Center and
provide the WLM IWMEJOIN service reason code.
The reason code code contains both the return
code (RC) and the reason code (RS). A dump of
the GRS address space may also be required.
- ISGAU014 - TRANSWAP RC = xx
The monitor could not be started because
the SYSEVENT TRANSWAP serviced returned an
unexpected return code of xx.
- ISGAU015 - DATA SPACE FULL
- ISGAU016 - MONITOR STOPPED - QUEUE THRESHOLD EXCEEDED
- ISGAU017 - MONITOR STOPPED - DATASET(S) NO LONGER ACCESSIBLE
Figure 2 shows
the abend the monitor issues.
Figure 2. AUDIT Abends - ABEND 1FF
RC=8 STOP/MODIFY PROBLEMS
The monitor terminates if both output data sets are full or an
unexpected error occurs. For any abend condition, the monitor will
writes a logrec record for diagnostic information.