Restrictions for console names

z/OS MVS Planning: Operations
SA23-1390-00

Console names must be from 2 to 8 characters and cannot start with a digit. Characters are alphanumeric and can also include the characters #, $, and @. When naming MCS consoles, do not use the following names:
  • HC
  • INSTREAM
  • INTERNAL
  • LOGON
  • LOGOFF
  • OPERLOG
  • SYSIOSRS
  • SYSLOG
  • UNKNOWN

Note about SYSIOSRS

Console name SYSIOSRS is reserved for system use.

The IOSAS address space must have an associated “trusted” userid defined in the RACF® started procedures table (ICHRIN03). This will permit the IOSAS address space to issue commands to the SYSIOSRS extended console. For more information, see z/OS Security Server RACF Security Administrator's Guide

Also, do not use console names that might be confused with device numbers. For example, the following name is not a good choice:
NAME(BAD)

For information on the system console and naming restrictions, see Naming the system console.