z/OS MVS Planning: Operations
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


MPF and MVS operations planning

z/OS MVS Planning: Operations
SA23-1390-00

The message processing facility (MPF) controls message processing for an MVS™ system. It controls the following:
  • Message presentation (the color, intensity and highlighting, of messages) for an MCS, HMCS or SMCS console
  • The suppression of messages
  • The retention of messages for the action message retention facility
  • Which subsystems, if any, are to receive foreign messages.
  • The selection of messages for automation programs like NetView®
  • Message processing exits other than IEAVMXIT that gain control when certain messages are issued
  • Command installation exits that gain control when commands are issued

You can specify presentation options, message retention, message suppression, selection of messages by an automation program, and user exit information in the MPFLSTxx Parmlib member.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014