Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
IPLing a system that shares DASD z/OS MVS Planning: Operations SA23-1390-00 |
|
Shared DASD can also affect how an operator IPLs a system that
requires devices in use by other systems. An operator might have
to re-IPL a system that is sharing DASD. If a device is being used
by another system, the initializing system waits and then issues the
following message to the operator:
The operators should reply with “WAIT”. “WAIT” causes the system to wait until the reserved device is released. If the system waits more than one minute, the operator should re-IPL. If the device is still reserved, the system reissues message IOS120A. The operator should then reply with “CONT” and the path to the device is marked offline to the system. Thus, the device is also unavailable to jobs running on the system. |
Copyright IBM Corporation 1990, 2014
|