z/OS MVS Using the Subsystem Interface
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


Input Parameters

z/OS MVS Using the Subsystem Interface
SA38-0679-00

Input parameters for the function routine are:
  • SSOB
  • SSIB
  • SSVS
SSOB Contents: The caller sets the following fields in the SSOB control block on input:
Field Name
Description
SSOBID
Identifier 'SSOB'
SSOBLEN
Length of the SSOB (SSOBHSIZ) control block
SSOBFUNC
SSI function code 15 (SSOBVERS)
SSOBSSIB
Address of an SSIB control block or zero (if this field is zero, the life-of-job SSIB is used). See Subsystem Identification Block (SSIB) for more information on the life-of-job SSIB.
SSOBINDV
Address of the function dependent area (SSVS control block)

Set all other fields in the SSOB control block to binary zeros before issuing the IEFSSREQ macro.

SSIB Contents: If you don't use the life-of-job SSIB, the caller must provide an SSIB and set the following fields in the SSIB control block on input:
Field Name
Description
SSIBID
Identifier 'SSIB'
SSIBLEN
Length of the SSIB (SSIBSIZE) control block
SSIBSSNM
Subsystem name — name of the subsystem that this verify subsystem function call is directed to (MSTR).
SSIBJBID
Name of the subsystem to be verified
Note: This is an 8-character field. Because subsystem names can only be 1-4 characters, the subsystem name specified should be left-justified and padded to the right with blank (X'40') characters.

Set all other fields in the SSIB control block to binary zeros before issuing the IEFSSREQ macro.

SSVS Contents: The caller sets the following fields in the SSVS control block on input:
Field Name
Description
SSVSLEN
Length of the SSVS (SSVSSIZE) control block

Set all other fields in the SSVS control block to binary zeros before issuing the IEFSSREQ macro.

Go to the previous page Go to the next page