Each application that uses a coupling facility structure must provide the information necessary to define the structure in a CFRM policy. In z/OS®, information about the following structures for IBM® products can be found in the associated documentation.

Table 1. Coupling facility structures in z/OS for IBM products
Structure Function Structure Type User-Managed Rebuild User-Managed Duplexing Rebuild Alter System-Managed Processes Where Documented
XCF signaling List Yes No Yes No See Planning signaling services in a sysplex.
Note: For communications in the sysplex, JES3 uses the XCF signaling structure if it is defined. As a result, you do not need to define JES3 signaling structures in the sysplex. For information about JES3 and the sysplex, see z/OS JES3 Initialization and Tuning Guide.
Start of change XCF Note Pad End of change Start of change List End of change Start of change No End of change Start of change No End of change Start of change Yes End of change Start of change Yes End of change Start of change See Planning XCF Note Pad Services in a sysplex. End of change
VTAM® generic resources function List Yes No Yes Yes z/OS Communications Server: SNA Network Implementation Guide
TCP/IP functions - sysplexports and sysplex wide security associations List Yes No No Yes z/OS Communications Server: SNA Network Implementation Guide
JES2 checkpoint data set in a coupling facility List No No No Yes z/OS JES2 Initialization and Tuning Guide
IMS™ DBCTL DL/I datasharing with IRLM 2.1
  • IRLM locking
  • OSAM buffer invalidate
  • VSAM buffer invalidate
  • Lock (IRLM)
  • Cache (OSAM)
  • Cache (VSAM)
  • Yes
  • Yes
  • Yes
  • No
  • No
  • No
  • Yes
  • No
  • Yes
  • Yes PQ45407
  • No
  • No
IMS Version 8: Administration Guide: System
IMS DEDB shared VSO data sharing Cache No No No Planned IMS Version 8: Administration Guide: System
IMS shared message queues List Yes No No Planned IMS Version 8: Administration Guide: Transaction Manager
RACF® data base in a large sysplex environment Cache Yes No No No z/OS Security Server RACF System Programmer's Guide
Automatic tape switching List Yes No No No See Using automatic tape switching (ATS STAR).
DB2® data sharing
  • Cache
  • Lock
  • List
  • Yes
  • Yes
  • Yes
  • Yes
  • No
  • No
  • Yes
  • Yes
  • Yes
  • No
  • Yes PQ45407
  • Yes
DB2 Data Sharing: Planning and Administration
Log stream data sharing List Yes No Yes Yes See Planning for system logger applications.
Global resource serialization star complex Lock Yes No No No z/OS MVS Planning: Global Resource Serialization
CICS® temporary storage data sharing List No No Yes Yes CICS System Definition Guide
CICS TS coupling facility data tables List No No Yes Planned CICS System Definition Guide
CICS TS named counter server List No No No Planned CICS System Definition Guide
VSAM record level sharing
  • Cache
  • Lock
  • Yes
  • Yes
  • No
  • No
  • No
  • No
  • No
  • Yes
z/OS DFSMSdfp Storage Administration
Batch Pipes List Yes No Yes Planned BatchPipes® OS/390® Users Guide and Reference
Enhanced Catalog Sharing Cache No No No No z/OS DFSMS Managing Catalogs
MQ shared queues List No No   Yes MQSeries® for OS/390 System Management Guide
WLM multisystem enclaves Cache Yes No Yes (Size only) Yes z/OS MVS Planning: Workload Management
Intelligent Resource Director (LPAR CPU Management, Dynamic Channel Path Management) Cache No No Yes (Size only) Yes z/OS MVS Planning: Workload Management
Note:
  1. DB2 and IMS documentation is available in the IBM Information Management Software for z/OS Solutions Information Center.
  2. CICS documentation is available in the CICS Transaction Server for z/OS Information Center.

Go to the previous page Go to the next page




Copyright IBM Corporation 1990, 2014