If you did not obtain the GFTAXTR output, make sure that:
  • Your SMF input includes types 14 and 15 records.
  • These 14 and 15 records are for tape, not DASD.
  • You have type 21 records in your SMF input.
  • You have type 30 records that correspond to tape mount and open activity.
  • Tapes were mounted during the period specified for SMF record collection.
  • You do not have many mismatches in the time frame of records for demounts (21) and records for opens (14/15).
  • Your SMF records are not altered. They must correspond to the formats in z/OS MVS System Management Facilities (SMF).
  • Your SMF records have the correct length. If your installation writes its own SMF records, they might have incorrect length. GFTAXTR inspects each record type for a minimum length value. If the length of the record is less than the standard SMF record format, then GFTAXTR will not use the short records. See z/OS MVS System Management Facilities (SMF) for more information.
  • You did not over-filter and exclude all SMF records.