Use the MVS LIBRARY SETCL command to set the media type of scratch
volumes to be loaded into the cartridge loaders of library-resident
tape drives. The syntax of the LIBRARY SETCL command follows:
>>-+-LIBRARY-+--+-SETCL-+--,--+-device_number-+--,media_type---><
'-LI------' '-SC----' '-device_range--'
- SETCL | SC
- Specifies a request to set the media type of scratch volumes
to be loaded into the cartridge loader of library-resident tape drives.
- device_number
- Specifies the MVS device number (xxxx).
- device_range
- Specifies the MVS device range (xxxx–yyyy).
The device number (xxxx) must be less than the device number
(yyyy).
- media_type
- Specifies the media type to be loaded:
- MEDIA1
- Specifies IBM Cartridge System Tape.
- MEDIA2
- Specifies IBM Enhanced Capacity Cartridge System Tape.
- MEDIA3
- Specifies IBM High Performance Cartridge Tape.
- MEDIA4
- Specifies IBM Expanded High Performance Cartridge Tape.
- MEDIA5
- Specifies IBM Enterprise Tape Cartridge.
- MEDIA6
- Specifies IBM Enterprise WORM Tape Cartridge.
- MEDIA7
- Specifies IBM Enterprise Economy Tape Cartridge.
- MEDIA8
- Specifies IBM Enterprise Economy WORM Tape Cartridge.
- MEDIA9
- Specifies IBM Enterprise Extended Tape Cartridge
- MEDIA10
- Specifies IBM Enterprise Extended WORM Tape Cartridge
- MEDIA11
- Specifies IBM Enterprise Advanced Tape Cartridge
- MEDIA12
- Specifies IBM Enterprise Advanced WORM Tape Cartridge
- MEDIA13
- Specifies IBM Enterprise Advanced Economy Tape Cartridge
- NONE
- In an ATLDS, the cartridge loader is emptied. In an MTL, indexing
is not occurring on this system; however, indexing could be occurring
on another system.
- ANY
- Valid for MTL only. Media type preferencing through data class
is not being used; therefore, index with media appropriate for the
drive.
Note: Use this command only for devices in a tape library
that have installed cartridge loaders.