0 |
Successful |
0 |
Successful execution. |
4 |
Warning |
8 |
Scratch volume threshold message
processing did not successfully complete. Check the console log for
further diagnostic information. |
|
|
138 |
The library scratch volume count
is not updated in TCDB. |
8 |
Invalid request |
9 |
Required type parameter not specified. |
|
|
11 |
Invalid value specified for type. |
|
|
12 |
Required function parameter not specified. |
|
|
13 |
Invalid value specified for function. |
|
|
17 |
Invalid volume serial number specified. |
|
|
20 |
Required volume list not specified. |
|
|
21 |
Invalid header value specified in
volume list. |
|
|
23 |
Required library name parameter not
specified. |
|
|
26 |
MCE library is not defined to storage
group on tape volume record. |
|
|
27 |
Invalid library name specified. |
|
|
29 |
Invalid parameter address specified
for LCSPL or VOLLIST. |
|
|
30 |
LCSPL or VOLLIST not aligned on fullword
boundary. |
|
|
34 |
Invalid storage group name. |
|
|
35 |
Required media type not specified
from any source. |
|
|
53 |
Library not defined to active configuration. |
|
|
54 |
Storage group specified on volume
record is type tape. |
|
|
92 |
Library specified is not an MTL. |
|
|
94 |
Specified volume already resides
in another tape library. |
|
|
97 |
Volume of same name is known DASD
volume. |
|
|
130 |
Specified volume already resides
in this tape library |
12 |
Failure |
60 |
Failure accessing SMS storage group
constructs. |
|
|
75 |
UCB scan failure when attempting
to determine volume serial uniqueness. |
|
|
78 |
Catalog failure when attempting to
retrieve the volume record. |
|
|
79 |
Catalog failure when attempting to
update the volume record. |
|
|
84 |
Abend occurred during LCS External
Services processing. |
|
|
95 |
Installation exit vetoed the entry
of the volume into the library. |
|
|
96 |
Installation exit said to ignore
the volume. |
|
|
310 |
Media type or recording technology
not supported at this software level. |
|
|
321 |
The media type returned from the
Installation Exit does not match the existing media type defined for
the volume record in TCDB. |
16 |
Environment |
2 |
OAM control block structure not available.1 |
|
|
80 |
LCS External Services unable to establish
an ESTAE. |
|
|
90 |
Cartridge entry disabled due to an
error in the installation exit. |
|
|
91 |
Cartridge entry temporarily suspended. |
1 Depending on the
CBRXLCS function being performed, one or more OAM initialization-related
control blocks might be required. First, verify whether the OAM1 subsystem
entry was specified in the IEFSSNxx PARMLIB
member. Then verify whether the OAM address space has been started. |