Table 1. DEVICE (Network BSC line)
Variable Value
Required/Optional Statement Optional
Statement Default None
Placement in Initialization Stream This statement must follow the ENDJSAM statement.
Coding Considerations
  1. Although you cannot code the DGROUP parameter, JES3 assigns all network lines or connections to the device group named NETWORK.
  2. The JUNIT parameter has a dependency on the NAME parameter of the MAINPROC statement. During a hot start with refresh, the MAINPROC statement is not processed; the MAINPROC from the last warm or cold start is used. Therefore, if you add a MAINPROC statement during a hot start with refresh, JES3 ignores it. JES3 issues error messages if the JUNIT parameter of the DEVICE statement references a MAINPROC statement that was added during a hot start with refresh.
Security Usage None
Performance Considerations None
Initialization Stream Overrides None
Restart or Command Modification Cold start, warm start, or hot start with refresh for all parameters.