z/OS Communications Server: IP Messages Volume 1 (EZA)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZA5176E

z/OS Communications Server: IP Messages Volume 1 (EZA)
SC27-3654-00

LOGFILE DD card missing, NOLOG forced.

Explanation

The LOG statement was present in hlq.SMTP.CONFIG and there was no LOGFILE DD parameter in SEZAINST(SMTPPROC) specifying the name of the data set used for the mail logging. SMTP does not log the mail.

System action

SMTP continues.

Operator response

Change the LOGFILE DD statement in the SEZAINST (SMTPROC) to a valid data set name. For more information on the LOGFILE DD statement and the configuring process, see the z/OS Communications Server: IP Configuration Reference.

System programmer response

No action is needed.

Module

SMTP

Procedure name

OpenOutputStreams

Go to the previous page Go to the next page