Previous topic |
Next topic |
Contents |
Contact z/OS |
Library |
PDF
EZZ9678E z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM) SC27-3657-01 |
|
EZZ9678E tcpstackname DETERMINED THAT OMPROUTE
WAS NOT RESPONSIVE FOR AT LEAST timevalue SECONDS ExplanationSysplex problem detection has determined that OMPROUTE was not responsive. tcpstackname is the name of the TCP/IP stack. timevalue is the number of seconds OMPROUTE was not responsive. This value is determined by the GLOBALCONFIG SYSPLEXMONITOR timersecs parameter in the TCP/IP profile. See the z/OS Communications Server: IP Configuration Guide and the z/OS Communications Server: IP Configuration Reference for more information about the timersecs parameter and how it is used to detect OMPROUTE unresponsiveness. System actionTCP/IP continues.
See Sysplex problem detection and recovery in z/OS Communications Server: IP Configuration Guide for more information. See GLOBALCONFIG statement in z/OS Communications Server: IP Configuration Reference for the definition of the SYSPLEXMONITOR parameters. Operator responseIf RECOVERY is active, and no 4C5 abend occurred, start the OMPROUTE procedure for this stack. If OMPROUTE
successfully starts, this operator message will be deleted.
If an abend occurred, save this documentation and contact the system programmer. System programmer responseIf this message is displayed, but OMPROUTE is active, then it might not be getting enough CPU cycles to complete the task; OMPROUTE should run under the WLM service class SYSSTC (the default service class for started tasks). It might be necessary to run OMPROUTE as non-swappable. See the network design considerations with z/OS® Communications Server information in z/OS Communications Server: IP Configuration Guide for more information about improving OMPROUTE performance. If the OMPROUTE performance problem cannot be determined, contact the IBM® support center with any supporting ABEND documentation. ModuleEZBXFPDM Procedure nameEZBXFPDM |
Copyright IBM Corporation 1990, 2014
|