EZZ9379I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ9379I
isc_condition_init(writeable) failed: error_text

Explanation

The named server failed to initialize the thread condition variable because of insufficient memory. The read/write lock conditional variable is not set.

error_text describes the error.

System action

The named server might end depending on the severity of the problem.

Operator response

Contact the system programmer.

System programmer response

Increase the TSO address space or region size and restart the named server.

Module

RWLOCK

Procedure name

print_lock