z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
Previous topic | Next topic | Contents | Contact z/OS | Library | PDF


EZZ7814I

z/OS Communications Server: IP Messages Volume 4 (EZZ, SNM)
SC27-3657-01

EZZ7814I
Unable to create socket type type, errno=errno:description, errno2=errnojr

Explanation

An attempt to create a socket of the specified type failed with the specified error.

errno is the z/OS® UNIX System Services return code. These return codes are listed and described in the return codes (errnos) information in z/OS UNIX System Services Messages and Codes.

description describes the meaning of the errno.

errnojr is the hexadecimal z/OS UNIX System Services reason code. The format of the 4-byte reason code is explained in the introduction to the reason codes (errnojrs) information of the z/OS UNIX System Services Messages and Codes, where the reason codes are listed.

System action

OMPROUTE ends.

Operator response

None.

System programmer response

Attempt to correct the system error reported. A possible cause is the TCP/IP stack not being started. If problem persists, there is a possible internal error, contact the IBM® software support center.

Module

EZAORINI, EZAORRTI, EZAORYAC, EZA6RINI